Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Catheter Cardiovasc Interv ; 97(4): E580-E587, 2021 03.
Article in English | MEDLINE | ID: mdl-32894804

ABSTRACT

OBJECTIVES: We sought to document aortic cusps fluoroscopic projections and their distributions using leaflet alignment which is a novel concept to optimize visualization of leaflets and for guiding BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction) and determine whether these projections were feasible in catheter laboratory. BACKGROUND: Optimal fluoroscopic projections of aortic valve cusps have not been well described. METHODS: A total of 128 pre-transcatheter aortic valve replacement (pre-TAVR) computed tomographies (CT) (72 native valves and 56 bioprosthetic surgical valves) were analyzed. Using CT software (3Mensio, Pie medical imaging, the Netherlands), leaflet alignment was performed and the feasibility of these angles, which were defined as rate of obtainable with efforts (within LAO/RAO of 85° and CRA/CAU of 50°) were evaluated. RESULTS: High feasibility was seen in right coronary cusp (RCC) front view (100%) and left coronary cusp (LCC) side view (99.2%), followed by noncoronary cusp side view (95.3%). In contrast, low feasibility of RCC side view (7.8%) and LCC front view (47.6%) was observed. No statistical differences were seen between the distribution of native valves and bioprosthetic surgical valves. With patient/table tilt of 20°LAO and 10°CRA, the feasibility of RCC side view and LCC front view increased to 43.7 and 85.2%, respectively. CONCLUSION: Distributions of each cusp's leaflet alignment follows "sigmoid curve" which can provide better understanding of aortic valve cusp orientation in TAVR and BASILICA. RCC side view used in right cusp BASILICA is commonly unachievable in catheter laboratory and may improve with patient/table tilt.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
2.
J Cardiovasc Comput Tomogr ; 14(6): 516-519, 2020.
Article in English | MEDLINE | ID: mdl-32199758

ABSTRACT

BACKGROUND: Eccentricity of coronary ostial positions in relation to the aortic valve cusp may influence the target laceration location in BASILICA (Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Coronary Artery obstruction). Eccentricity of the coronary ostia in relation to coronary cusps of native and valve-in-valve transcatheter aortic valve replacement (TAVR) was not well described before. METHODS: A total of 121 pre-TAVR patients' CT data (72 native valves TAVR and 49 bioprosthetic surgical valves TAVR) was included and coronary ostial eccentricity angles were measured and compared. Coronary ostial angles were measured between mid-cusp line to coronary ostium in CT perpendicular images. RESULTS: In the overall cohort, the right coronary artery (RCA) had an eccentric origin in the majority of cases, favoring the commissure between the right and the non coronary cusp (17.0°, IQR; 10-25). On the other hand, the left coronary artery (LCA) originated most commonly near center of the cusp position (0°, IQR; -8 -7.5) In comparison of native and bioprosthetic valves, RCA ostial angles were more eccentric in native valves (19.0°, IQR; 12-26) than in bioprosthetic valves (14.0°, IQR; 3-20) (p = 0.004). Whereas, LCA ostial angle has no significant differences between native valves (-2.0°, IQR;-7.75-5.75) and bioprosthetic valves (1°, IQR;-8-13), (p = 0.6). CONCLUSION: RCA ostia often have an eccentric origin towards the non-coronary cusp, especially in native aortic valves, while LCA ostia commonly originate near the center of the cusp. This finding may contribute to better performance of BASILICA procedures.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Computed Tomography Angiography , Coronary Angiography , Coronary Stenosis/prevention & control , Coronary Vessels/diagnostic imaging , Heart Valve Prosthesis , Multidetector Computed Tomography , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/etiology , Female , Humans , Male , Predictive Value of Tests , Prosthesis Design , Risk Factors , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
3.
JACC Cardiovasc Interv ; 13(2): 210-216, 2020 01 27.
Article in English | MEDLINE | ID: mdl-31883715

ABSTRACT

OBJECTIVES: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak. METHODS: From December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported. RESULTS: The mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p < 0.001 for both). Mild paravalvular aortic regurgitation occurred in 21.7% of patients, while moderate or greater paravalvular aortic regurgitation occurred in 4.3%. Mild and moderate or severe transvalvular aortic regurgitation occurred in 11.6% and 0%, respectively. Valve gradients remained stable at 1 year. CONCLUSIONS: S3 TAVR in annular areas >683 mm2 is feasible, with favorable mid-term outcomes.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Male , North America , Postoperative Complications/mortality , Postoperative Complications/therapy , Recovery of Function , Retrospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
5.
JACC Cardiovasc Interv ; 11(14): 1377-1387, 2018 07 23.
Article in English | MEDLINE | ID: mdl-29960755

ABSTRACT

OBJECTIVES: The aim of this study was to determine factors affecting paravalvular leak (PVL) in transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: The largest recommended annular area for the 29-mm S3 is 683 mm2. However, experience with S3 TAVR in annuli >683 mm2 has not been widely reported. METHODS: From December 2013 to July 2017, 74 patients across 16 centers with mean area 721 ± 38 mm2 (range: 684 to 852 mm2) underwent S3 TAVR. The transfemoral approach was used in 95%, and 39% were under conscious sedation. Patient, anatomic, and procedural characteristics were retrospectively analyzed. Valve Academic Research Consortium-2 outcomes were reported. RESULTS: Procedural success was 100%, with 2 deaths, 1 stroke, and 2 major vascular complications at 30 days. Post-dilatation occurred in 32%, with final balloon overfilling (1 to 5 ml extra) in 70% of patients. Implantation depth averaged 22.3 ± 12.4% at the noncoronary cusp and 20.7 ± 9.9% at the left coronary cusp. New left bundle branch block occurred in 17%, and 6.3% required new permanent pacemakers. Thirty-day echocardiography showed mild PVL in 22.3%, 6.9% moderate, and none severe. There was no annular rupture or coronary obstruction. Mild or greater PVL was associated with larger maximum annular and left ventricular outflow tract (LVOT) diameters, larger LVOT area and perimeter, LVOT area greater than annular area, and higher annular eccentricity. CONCLUSIONS: TAVR with the 29-mm S3 valve beyond the recommended range by overexpansion is safe, with acceptable PVL and pacemaker rates. Larger LVOTs and more eccentric annuli were associated with more PVL. Longer term follow-up will be needed to determine durability of S3 TAVR in this population.


Subject(s)
Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Humans , Male , Prosthesis Design , Registries , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , United States
6.
J Cardiol Cases ; 13(4): 105-108, 2016 Apr.
Article in English | MEDLINE | ID: mdl-30546619

ABSTRACT

A 68-year-old woman presented to our hospital with unstable angina and was admitted for further evaluation. While hospitalized, she developed persistent angina with hypotension along with ST-segment elevation in leads V1-V2 along with lead aVR elevation on 12-lead electrocardiogram. Coronary angiography revealed diffuse multi-vessel coronary vasospasm most notably in the left anterior descending artery (LAD). Due to incomplete resolution of vasospasm with intracoronary verapamil and nitroglycerin, along with hemodynamic compromise requiring an intra-aortic balloon pump, percutaneous coronary intervention (PCI) of the LAD was performed. Clinical workup revealed hypereosinophlia and elevated IgE; diagnosis of eosinophilic granulomatosis with polyangiitis was confirmed with evidence of radiographic migratory pulmonary infiltrates and airway obstruction on spirometry. The patient had recurrent angina after PCI but her symptoms resolved fully after a course of corticosteroids. We attribute her refractory vasospastic angina to previously undiagnosed small/medium-vessel vasculitis. .

SELECTION OF CITATIONS
SEARCH DETAIL
...