Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Arch Bone Jt Surg ; 10(1): 85-91, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35291250

ABSTRACT

Background: Cemented Total Knee Arthroplasty (TKA) provides excellent long-term survival rates and functional results, however, radiolucent lines (RLLs) often appear during early post-operative follow-up and their incidence and clinical significance are unknown. The primary aim was to establish the incidence, location, frequency, and time taken for RLLs to appear within the first year after a primary cemented TKA with an anatomic tibial baseplate (Smith and Nephew, LEGION Total Knee System). Methods: This was a retrospective analysis of 135 primary cemented TKA in 131 patients over three years. We compared demographics, serial radiographs, and early clinical and functional outcomes. Results: There were 65 TKAs (48%) in 62 patients who had RLLs within the first year post-operatively. Most were females (58.8%). Mean age was 68.3 ± 7.9 years. There were 88 RLLs, with the most and second commonest location at the medial tibial baseplate (38%) and anterior femoral flange (23%). 89% were in the bone-cement interface. The largest average length of RLLs were at the anterior flange of the femoral component (1.98 ± 1.33 mm). The average time to development was 6.5 ± 4.1 months. None of these patients had infections nor required revision. Patients with RLLs did not do worse in functional and clinical scoring at 1-year. Conclusion: There was a 48% incidence of physiological RLLs after cemented TKA, with the highest occurrence at the medial tibial baseplate at 38%. These radiolucent lines did not affect early post-operative clinical and functional outcomes of patients.

3.
Sci Rep ; 11(1): 23997, 2021 12 14.
Article in English | MEDLINE | ID: mdl-34907270

ABSTRACT

Although both long and short cephalomedullary devices (CMDs) are used in the treatment of extracapsular hip fractures, the advantages of either option are subject to debate. This study aims to evaluate the differences in clinical outcomes with long versus short CMDs for extracapsular hip fractures. Studies included must have included subjects with at least 1 year of follow-up and reported on at least one of the following outcomes: rate of reoperation; rate of peri-implant fracture; operating time; blood loss; complication rate; length of hospital stay; 1-year mortality. Only articles written in the English language were included in this study. A search was conducted across the databases of Medline, Embase, CENTRAL (Cochrane Central Register of Controlled Trials), CINAHL and Scopus for articles published from the inception of the database to 1 November 2020. Included studies were assessed for their risk of bias using the Risk of Bias Tool (RoB2) and the risk-of-bias in non-randomized studies - of interventions (ROBINS-I) tool. A total of 8460 fractures from 16 studies were included in the analysis, with 3690 fixed with short, and 4770 fixed with long CMDs. A meta-analysis of the results revealed that short CMDs offer peri-operative advantages, while long CMDs could offer longer-term advantages. Limitations of this study include a lack of randomized control trials included in the analysis. In conclusion, when planning for the treatment of extracapsular hip fractures, a patient specific approach may be necessary to make a decision according to the individual risk profile of the patient.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Hip Fractures/surgery , Reoperation , Hip Fractures/mortality , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...