Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Int J Surg ; 109(5): 1271-1280, 2023 May 01.
Article in English | MEDLINE | ID: mdl-36999783

ABSTRACT

INTRODUCTION: Cervical spine fractures with severe spinal cord injury (SCI) are common following cervical spine trauma and are associated with a high mortality rate. Understanding the mortality patterns of patients with cervical spine fractures and severe SCI can offer valuable evidence to surgeons and family members who are required to make critical healthcare decisions. The authors aimed to evaluate the instantaneous death risk and conditional survival (CS) of such patients and developed conditional nomograms to account for different periods of survivors and predict the survival rates. METHODS: Their instantaneous death risks were calculated using the hazard function, and the Kaplan-Meier method was used to evaluate the survival rates. Cox regression was used to choose the variables for the construction of the nomograms. The area under the receiver operating characteristic curve and calibration plots were used to validate the performance of the nomograms. RESULTS: The authors finally included 450 patients with cervical spine fractures and severe SCI using propensity score matching. The instantaneous death risk was the highest during the first 12 months after injury. Surgical treatment can help decrease the instantaneous death risk quickly, especially in early-term surgery. The 5-year CS increased constantly from 73.3% at baseline to 88.0% after 2 years of survival. Conditional nomograms were constructed at baseline and in those who survived for 6 and 12 months. The area under the receiver operating characteristic curve and calibration curves indicated that the nomograms had a good performance. CONCLUSION: Their results improve our understanding of the instantaneous death risk of patients in different periods following injury. CS demonstrated the exact survival rate among medium-term and long-term survivors. Conditional nomograms are suitable for different survival periods in predicting the probability of survival. Conditional nomograms help in understanding the prognosis and improve the shared decision-making approaches.


Subject(s)
Spinal Cord Injuries , Spinal Fractures , Humans , Nomograms , Retrospective Studies , Prognosis , Spinal Fractures/etiology , Spinal Fractures/surgery , Spinal Cord Injuries/complications , Cervical Vertebrae/injuries
2.
Mater Today Bio ; 18: 100500, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36471893

ABSTRACT

Polymethyl methacrylate (PMMA) bone cement (PBC) is commonly used in orthopaedic surgery. However, polymerization volumetric shrinkage, exothermic injury, and low bioactivity prevent PBC from being an ideal material. The developed expandable P(MMA-AA-St) well overcomes the volumetric shrinkage of PBC. However, its biomechanical properties are unsatisfactory. Herein, graphene oxide (GO), a hydrophilic material with favourable biomechanics and osteogenic capability, was added to P(MMA-AA-St) to optimize its biomechanics and bioactivity. The GO-modified self-expandable P(MMA-AA-St)-GO nanocomposite (PGBCs) exhibited outstanding compressive strength (>70 â€‹MPa), water absorption, and volume expansion, as well as a longer handling time and a reduced setting temperature. The cytocompatibility of PGBCs was superior to that of PBC, as demonstrated by CCK-8 assay, live-dead cell staining, and flow cytometry. In addition, better osteoblast attachment was observed, which could be attributed to the effects of GO. The improved level of osteogenic gene and protein expression further illustrated the improved cell-material interactions between osteoblasts and PGBCs. The results of an in vivo study performed by filling bone defects in the femoral condyles of rabbits with PGBCs demonstrated promising intraoperative handling properties and convenient implantation. Blood testing and histological staining demonstrated satisfactory in vivo biosafety. Furthermore, bone morphological and microarchitecture analyses using bone tissue staining and micro-CT scanning revealed better bone-PGBCs contact and osteogenic capability. The results of this study indicate that GO modification improved the physiochemical properties, cytocompatibility, and osteogenic capability of P(MMA-AA-St) and overcame the drawbacks of PBC, allowing its material derivatives to serve as effective implantable biomaterials.

3.
Comput Biol Med ; 134: 104477, 2021 07.
Article in English | MEDLINE | ID: mdl-34010793

ABSTRACT

BACKGROUND: Different constructs are applied in revision surgery (RS) for adjacent segment disease (ASD) aiming to further decompress and fixate the affected segment(s) in two ways: replacing or preserving the primary implants. This study aimed to compare the biomechanical properties of four constructs with different configurations. METHODS: An T12-L5 finite element (FE) model was constructed and validated. Primary surgery was performed at L4-L5 and instrumented from L3 to L5. Thereafter, RS was undertook by decompressing L2-L3 and fixated with implant-replacing construct A, or implant-preserving construct B, C or D. Range of motion (ROM) and intervertebral disc pressure (IDP) were compared. Maximum von Mises stress on the rods between Construct A and B was evaluated. RESULTS: An obvious reduction of ROM was observed when the FE model was instrumented with four constructs respectively. The overall changing characteristics of ROM were approximately identical among four constructs. The changing characteristic of IDP among four constructs was similar. The degree of IDP reduction of Construct B was comparable to Construct A, while that of Construct C was comparable to Construct D. Maximum von Mises stress on the rods between Construct A and B indicated that no stress concentration was recorded at the locking part of the connector rod. CONCLUSIONS: The biomechanics of implant-preserving constructs were comparable to the traditional implant-replacing construct. The location of side-by-side connector could not affect the stability of Construct C and D. Construct B might be an optimal choice in RS for less dissection, less complication and more convenience in manipulation.


Subject(s)
Spinal Fusion , Finite Element Analysis , Lumbar Vertebrae/surgery , Lumbosacral Region , Reoperation
4.
Br J Neurosurg ; : 1-4, 2021 Mar 26.
Article in English | MEDLINE | ID: mdl-33769177

ABSTRACT

Spinal instrumented rod migrating from the surgical site to another remote site in the body is rare. Some cases result in organ or blood vessel injury. Most reported cases were asymptomatic until the finally injuries were generated. We report a unique case of spinal implant failure in which the rod moved from lumbar spine into chest 13 years post lumbar instrumentation. The migrated rod caused no damage to the organs in the pleural cavity but did cause an atypical pleural irritation syndrome which seemed to correlate with the mechanical irritation caused by the rod. These atypical symptoms of rod migration have not been reported previously.

5.
World Neurosurg ; 150: e511-e519, 2021 06.
Article in English | MEDLINE | ID: mdl-33744424

ABSTRACT

OBJECTIVE: To evaluate the mechanical properties of a new connector rod aiming to preserve implants in revision surgery (RS) for adjacent segment disease, a problematic complication of instrumented spinal fusion, and to assess its clinical applicability. METHODS: The mechanical properties of the connector-rod construct (implant preservation) and traditional rod construct (implant replacement) were evaluated and compared. Forty-three patients underwent RS for adjacent segment disease in the thoracolumbar spine with implant preservation or replacement, and radiological and clinical outcomes were assessed. RESULTS: Mechanical properties in group A were comparable to those in group B. Total mean time from prior surgery to RS was 6.86 ± 1.08 years. Surgical time and blood loss values of group A were 40.14% and 29.29% statistically significantly smaller than values of group B. In group B, 12% (3/25) of patients developed surgical site infections. In both groups, the visual analog scale leg score decreased significantly after RS. Early postoperative (at 1-month and 3-month follow-up) Oswestry Disability Index and visual analog scale back scores of group A were significantly lower than those of group B; the difference in the visual analog scale back score between groups was significant until the 6-month follow-up. No implant failures occurred, and spinal fusion was achieved in all cases. CONCLUSIONS: The connector rod is considered safe and can reduce the surgical time, blood loss, risk of complications, and medical costs. Better early postoperative clinical outcomes can be achieved with the rod owing to less surgical trauma.


Subject(s)
Postoperative Complications/surgery , Prostheses and Implants , Reoperation/instrumentation , Spinal Fusion/instrumentation , Aged , Female , Humans , Intervertebral Disc Degeneration/etiology , Intervertebral Disc Degeneration/surgery , Lumbar Vertebrae , Male , Middle Aged , Retrospective Studies , Spinal Fusion/adverse effects , Thoracic Vertebrae , Treatment Outcome
6.
Front Bioeng Biotechnol ; 9: 799727, 2021.
Article in English | MEDLINE | ID: mdl-35071208

ABSTRACT

Revision surgery (RS) is a necessary surgical intervention in clinical practice to treat spinal instrumentation-related symptomatic complications. Three constructs with different configurations have been applied in RS. One distinguishing characteristic of these configurations is that the revision rods connecting previous segments and revision segments are placed alongside, outside, or inside the previous rods at the level of facetectomy. Whether the position of the revision rod could generate mechanical disparities in revision constructs is unknown. The objective of this study was to assess the influence of the revision rod position on the construct after RS. A validated spinal finite element (FE) model was developed to simulate RS after previous instrumented fusion using a modified dual-rod construct (DRCm), satellite-rod construct (SRC), and cortical bone trajectory construct (CBTC). Thereafter, maximum von Mises stress (VMS) on the annulus fibrosus and cages and the ligament force of the interspinous ligament, supraspinous ligament, and ligamentum flavum under a pure moment load and a follower load in six directions were applied to assess the influence of the revision rod position on the revision construct. An approximately identical overall reducing tendency of VMS was observed among the three constructs. The changing tendency of the maximum VMS on the cages placed at L4-L5 was nearly equal among the three constructs. However, the changing tendency of the maximum VMS on the cage placed at L2-L3 was notable, especially in the CBTC under right bending and left axial rotation. The overall changing tendency of the ligament force in the DRCm, SRC, and CBTC was also approximately equal, while the ligament force of the CBTC was found to be significantly greater than that of the DRCm and SRC at L1-L2. The results indicated that the stiffness associated with the CBTC might be lower than that associated with the DRCm and SRC in RS. The results of the present study indicated that the DRCm, SRC, and CBTC could provide sufficient stabilization in RS. The CBTC was a less rigid construct. Rather than the revision rod position, the method of constructing spinal instrumentation played a role in influencing the biomechanics of revision.

7.
J Biomater Appl ; 35(2): 182-192, 2020 08.
Article in English | MEDLINE | ID: mdl-32338168

ABSTRACT

Extracellular matrix loss is one of the early manifestations of intervertebral disc degeneration. Stem cell-based tissue engineering creates an appropriate microenvironment for long term cell survival, promising for NP regeneration. We created a decellularized nucleus pulposus hydrogel (DNPH) from fresh bovine nucleus pulposus. Decellularization removed NP cells effectively, while highly preserving their structures and major biochemical components, such as glycosaminoglycan and collagen II. DNPH could be gelled as a uniform grid structure in situ at 37°C for 30 min. Adding adipose marrow-derived mesenchymal stem cells into the hydrogel for three-dimensional culture resulted in good bioactivity and biocompatibility in vitro. Meanwhile, NP-related gene expression significantly increased without the addition of exogenous biological factors. In summary, the thermosensitive and injectable hydrogel, which has low toxicity and inducible differentiation, could serve as a bio-scaffold, bio-carrier, and three-dimensional culture system. Therefore, DNPH has an outstanding potential for intervertebral disc regeneration.


Subject(s)
Biocompatible Materials/chemistry , Hydrogels/chemistry , Mesenchymal Stem Cells/cytology , Nucleus Pulposus/chemistry , Nucleus Pulposus/physiology , Regeneration , Animals , Cattle , Cell Survival , Intervertebral Disc Degeneration/therapy , Mesenchymal Stem Cell Transplantation , Nucleus Pulposus/cytology , Nucleus Pulposus/ultrastructure , Rats, Sprague-Dawley , Temperature , Tissue Engineering
8.
J Neurosurg Spine ; 24(6): 971-7, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26849712

ABSTRACT

OBJECTIVE This study investigated the optimum injection volume of polymethylmethacrylate (PMMA) to augment a novel fenestrated pedicle screw (FPS) with diameter-tapered perforations in the osteoporotic vertebral body, and how the distribution characteristics of PMMA affect the biomechanical performance of this screw. METHODS Two types of FPSs were designed (FPS-A, composed of 6 perforations with an equal diameter of 1.2 mm; and FPS-B, composed of 6 perforations each with a tapered diameter of 1.5 mm, 1.2 mm, and 0.9 mm from tip to head. Each of 28 human cadaveric osteoporotic vertebrae were randomly assigned to 1 of 7 groups: FPS-A1.0: FPS-A+1.0 ml PMMA; FPS-A1.5: FPS-A+1.5 ml PMMA; FPS-A2.0: FPS-A+2.0 ml PMMA; FPS-B1.0: FPS-B+1.0 ml PMMA; FPS-B1.5: FPS-B+1.5 ml PMMA; FPS-B2.0: FPS-B+2.0 ml PMMA; and conventional pedicle screws (CPSs) without PMMA. After the augmentation, 3D CT was performed to assess the cement distribution characteristics and the cement leakage rate. Axial pullout tests were performed to compare the maximum pullout force thereafter. RESULTS The CT construction images showed that PMMA bone cement formed a conical mass around FPS-A and a cylindrical mass around FPS-B. When the injection volume was increased from 1.0 ml to 2.0 ml, the distribution region of the PMMA cement was enlarged, the PMMA was distributed more posteriorly, and the risk of leakage was increased. When the injection volume reached 2.0 ml, the risk of cement leakage was lower for screws having diameter-tapered perforations. The pullout strengths of the augmented FPS-A groups and FPS-B groups were higher than that of the CPS group (p < 0.0001). All FPS-B groups had a higher pullout strength than the FPS-A groups. CONCLUSIONS The diameter of the perforations affects the distribution of PMMA cement. The diameter-tapered design enabled PMMA to form larger bone-PMMA interfaces and achieve a relatively higher pullout strength, although statistical significance was not reached. Study results indicated 1.5-ml of PMMA was a conservative volume for PMMA augmentation; more cement injection would significantly increase the risk of cement leakage.


Subject(s)
Bone Cements , Pedicle Screws , Polymethyl Methacrylate , Aged , Aged, 80 and over , Female , Humans , Imaging, Three-Dimensional , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Male , Orthopedic Procedures/methods , Prosthesis Design , Prosthesis Failure , Random Allocation , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/surgery , Tomography, X-Ray Computed
9.
J Spinal Disord Tech ; 28(3): E166-72, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25353202

ABSTRACT

STUDY DESIGN: A novel total cervical prosthesis (TCP) for single-level cervical subtotal corpectomy was assessed in a caprine animal model. OBJECTIVES: To investigate the radiologic and histomorphometric characteristics of a novel TCP for single-level cervical subtotal corpectomy. SUMMARY OF BACKGROUND: Cervical disk replacement has emerged as a promising alternative to arthrodesis in the management of cervical disk herniation. However, they are designed for anterior cervical discectomy, and not suitable for cervical subtotal corpectomy. To solve this problem, our group has developed a novel TCP for single-level cervical subtotal corpectomy. MATERIALS AND METHODS: There were 12 adult Shannxi goats (2 y old) used in this study. The goats were divided into 2 groups based on postoperative survival periods of 3 (n=6) and 6 (n=6) months after surgery. Using an anterior surgical approach, a standard anterior C3 vertebra subtotal corpectomy and decompression of the spinal canal were performed, followed by implantation of the TCP device. Then all the goats were killed and underwent radiographic and histologic observations. RESULTS: The TCP implant procedures were successfully completed in all 12 goats without incidence of vascular or infectious complications. The range of motion of C2-C3 and C3-C4 segments were preserved in both of the groups. Three-dimensional images of specimens interface indicated confluent interdigitization of trabeculae at the prosthetic endplate-bone interface, without evidence of significant radiolucent lines or gaps. Histomorphometric analysis showed that there were a large number of fibrous tissue and a small amount of cartilage cells between the prostheses and bone in the 3 months' group. In the 6 months' group, part of fibrous tissue has changed into the cartilage tissue. CONCLUSIONS: Our data show that this prosthesis can maintain the stability of the cervical spine and retain the activity of the cervical spine in vivo. The findings in this study provide a foundation for ongoing clinical investigations using the TCP.


Subject(s)
Cervical Vertebrae/surgery , Diskectomy/methods , Intervertebral Disc/surgery , Prosthesis Implantation , Animals , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/pathology , Decompression, Surgical , Goats , Intervertebral Disc/diagnostic imaging , Intervertebral Disc/pathology , Models, Animal , Radiography , Range of Motion, Articular
10.
PLoS One ; 9(3): e92085, 2014.
Article in English | MEDLINE | ID: mdl-24642982

ABSTRACT

Recent clinical studies indicated that angiotensin receptor blockers (ARBs) would decrease the risk of bone fractures in the elderly populations. There is little known about the role of the ARBs in the process of fracture healing. The purpose of the present study was to verify the hypothesis that systemic treatment with telmisartan has the ability to promote fracture healing. In this study, femur fractures were produced in 96 mature male BALB/c mice. Animals were treated with the ARBs telmisartan or vehicle. Fracture healing was analysed after 2, 5 and 10 weeks postoperatively using X-ray, biomechanical testing, histomorphometry, immunohistochemistry and micro-computed tomography (micro-CT). Radiological analysis showed the diameter of the callus in the telmisartan treated animals was significantly increased when compared with that of vehicle treated controls after two weeks of fracture healing. The radiologically observed promotion of callus formation was confirmed by histomorphometric analyses, which revealed a significantly increased amount of bone formation when compared with vehicle-treated controls. Biomechanical testing further showed a significantly greater peak torque at failure, and a higher torsional stiffness in telmisartan-treated animals compared with controls. There was an increased fraction of PCNA-positive cells and VEGF-positive cells in telmisartan-treated group compared with vehicle-treated controls. From the three-dimensional reconstruction of the bony callus, telmisartan-treated group significantly increased the values of BV/TV by 21.7% and CsAr by 26.0% compared to the vehicle-treated controls at 5 weeks post-fracture. In summary, we demonstrate in the current study that telmisartan could promote fracture healing in a mice model via increasing mechanical strength and improving microstructure. The most mechanism is probably by an increase of cell proliferation and neovascularization associated with a decreased VEGF expression in hypertrophic chondrocytes.


Subject(s)
Angiotensin II Type 1 Receptor Blockers/pharmacology , Benzimidazoles/pharmacology , Benzoates/pharmacology , Bony Callus/drug effects , Femoral Fractures/drug therapy , Femur/drug effects , Fracture Healing/drug effects , Administration, Oral , Animals , Biomarkers/metabolism , Bony Callus/diagnostic imaging , Bony Callus/injuries , Bony Callus/metabolism , Femoral Fractures/diagnostic imaging , Femoral Fractures/metabolism , Femur/diagnostic imaging , Femur/injuries , Femur/metabolism , Gene Expression , Immunohistochemistry , Male , Mice , Mice, Inbred BALB C , Proliferating Cell Nuclear Antigen/genetics , Proliferating Cell Nuclear Antigen/metabolism , Shear Strength , Telmisartan , Vascular Endothelial Growth Factor A/genetics , Vascular Endothelial Growth Factor A/metabolism , X-Ray Microtomography
SELECTION OF CITATIONS
SEARCH DETAIL
...