Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Acta Chim Slov ; 70(4): 509-515, 2023 Nov 10.
Article in English | MEDLINE | ID: mdl-38124645

ABSTRACT

A dinuclear oxidovanadium(V) complex [V2O2L2(OMe)2] (1) was synthesized from N'-(2-hydroxy-5-methylbenzylidene)-4-methylbenzohydrazide (H2L) and VO(acac)2 in MeOH. Reaction of complex 1 with 3-hydroxy-2-methyl-4-pyrone (HL') afforded a mononuclear oxidovanadium(V) complex [VOLL'] (2). The hydrazone and both complexes were characterized by IR, UV and 1H NMR spectroscopy, as well as X-ray single crystal determination. X-ray powder diffraction of the complexes was performed. The V atoms in the two complexes are in octahedral coordination. The molecules of complex 2 are linked through non-classical hydrogen bonds of type C-H∙∙∙O to form one-dimensional chains running along the a axis. The biological assay indicates that the complexes have good antimicrobial activities on the bacteria strains P. aeroginosa, S. aureus, B. subtilis and E. coli.


Subject(s)
Coordination Complexes , Escherichia coli , Anti-Bacterial Agents , Molecular Structure , Staphylococcus aureus , X-Rays , Vanadium/chemistry
2.
Cancer Med ; 12(16): 16687-16696, 2023 08.
Article in English | MEDLINE | ID: mdl-37602656

ABSTRACT

BACKGROUND: Circulating tumor DNA (ctDNA)-based minimal residual disease (MRD) detection, which can identify disease relapse ahead of radiological imaging, has shown promising performance. The objective of this study was to develop and validate OriMIRACLE S (Minimal Residual Circulating Nucleic Acid Longitudinal Detection in Solid Tumor), a highly sensitive and specific tumor-informed assay for MRD detection. METHODS: Tumor-specific somatic single nucleotide variants (SNVs) were identified via whole exome sequencing of tumor tissue and matched germline DNA. Clonal SNVs were selected using the OriSelector algorithm for patient-specific, multiplex PCR-based NGS assays in MRD detection. Plasma-free DNA from patients with gastrointestinal tumors prior to and following an operation, and during monitoring, were ultradeep sequenced. RESULTS: The detection of three positive sites was sufficient to achieve nearly 100% overall sample level sensitivity and specificity and was determined by calculating binomial probability based on customized panels containing 21 to 30 variants. A total of 127 patients with gastrointestinal tumors were enrolled in our study. Preoperatively, MRD was positive in 18 of 26 patients (69.23%). Following surgery, MRD was positive in 24 of 82 patients (29.27%). The positivity rate for MRD was 33.33% (n = 18) for gastric adenocarcinoma and 32.26% (n = 62) for colorectal cancer. Twenty (20) of 59 patients (34.48%) experienced a change in MRD status over the monitoring period. Patients 8 and 31 responded to 3 cycles of systemic therapy, after which levels for all ctDNA dropped below the detection limit. Patient 53 was an example of using MRD to predict tumor metastasis. Patient 55 showed a weak response to treatments first and respond to new systemic therapy after tumor progression. CONCLUSION: Our study identified a sensitive and specific clinical detection method for low frequency ctDNA, and explored the detection performance of this technology in gastrointestinal tumors.


Subject(s)
Carcinoma , Circulating Tumor DNA , Gastrointestinal Neoplasms , Humans , Circulating Tumor DNA/genetics , Neoplasm, Residual/genetics , Neoplasm Recurrence, Local , Gastrointestinal Neoplasms/diagnosis , Gastrointestinal Neoplasms/genetics
4.
PLoS One ; 17(5): e0268033, 2022.
Article in English | MEDLINE | ID: mdl-35522649

ABSTRACT

BACKGROUND: Pain management is currently important in neonatal intensive care unit (NICU). The superiority in pain relief of the combined oral sucrose (OS) and nonnutritive sucking (NNS) to other single intervention has not been well established. The administration of sucrose has been considered to potentially induce adverse events, which has been controversial. This study aims to investigate the combined effects and safety in comparison with other single intervention methods, including NNS, OS alone, breast milk and oral glucose. METHODS: We searched databases including Medline (via Pubmed), Embase (via Ovid), web of science, and Cochrane Library for randomized controlled trials from Jan 1, 2000 to Mar 31, 2021. The data were analyzed in the meta-analysis using Review manager Version 5.3. Pain score was the primary outcome in this meta-analysis. The adverse events were assessed qualitatively. RESULTS: A total of 16 studies were eligible in the meta-analysis. The results demonstrated a significant reduction in pain score in the NNS+OS group compared with NNS alone (SMD = -1.69, 95%CI, -1.69,-0.65) or sucrose alone (SMD = -1.39, 95% CI, -2.21,-0.57) during the painful procedures. When compared NNS+OS with breast milk, no significant difference was detected (SMD = -0.19, 95% CI: -0.5, 0.11). CONCLUSION: The combined effects of NNS and OS might be superior to other single intervention method. However, the effects might be mild for moderate-to-severe pain.


Subject(s)
Pain Management , Sucrose , Female , Humans , Infant , Infant, Newborn , Intensive Care Units, Neonatal , Pain , Pain Management/methods , Pain Measurement , Sucking Behavior , Sucrose/adverse effects
5.
Medicine (Baltimore) ; 101(7): e28789, 2022 Feb 18.
Article in English | MEDLINE | ID: mdl-35363166

ABSTRACT

ABSTRACT: There are needs to investigate the influencing factors of necrotizing enterocolitis (NEC) in low birth weight (LBW) newborns, to provide insights into the clinical management of NEC.This study was a retrospective cohort study. Infants admitted to our hospital from January 1, 2019 to June 30, 2021 were selected. The clinical characteristics of NEC and no-NEC infants were evaluated. Logistic regression analyses were conducted to assess the risk factors of NEC in LBW infants.A total of 192 LBW infants were included, the incidence of NEC in LBW infants was 35.42%. There were significant differences in the congenital heart disease, sepsis, breastfeeding, blood transfusion and probiotics feeding between NEC and no-NEC group (all P < .05), and there were no significant differences in birth weight, gestational age, mother's pregnancy-induced hypertension, premature rupture of fetal membrane, amniotic fluid pollution, fetal asphyxia, neonatal respiratory distress syndrome and mechanical ventilation between NEC and no-NEC group (all P > .05). Congenital heart disease (OR: 2.128, 95% CI: 1.103-3.511), sepsis (OR: 1.630, 95% CI: 1.022-2.549), and blood transfusion (OR: 1.451, 95% CI: 1.014-2.085) were the independent risk factors for NEC in LBW infants, and breastfeeding (OR: 0.494, 95% CI: 0.023-0.928), probiotics feeding (OR: 0.816, 95% CI: 0.782-0.982) were the protective factors for the NEC in LBW infants. The prognosis of NEC infants undergone surgery treatment was better than that of infants undergone conservative treatments (P = .043).The incidence of NEC in LBW is high, which is affected by many factors, and comprehensive interventions targeted on the risk and protective factors should be made to improve the prognosis of LBW infants.


Subject(s)
Enterocolitis, Necrotizing , Birth Weight , Enterocolitis, Necrotizing/epidemiology , Female , Gestational Age , Humans , Infant , Infant, Newborn , Infant, Very Low Birth Weight , Pregnancy , Retrospective Studies
6.
Se Pu ; 40(1): 57-65, 2022 Jan.
Article in Chinese | MEDLINE | ID: mdl-34985216

ABSTRACT

Chromatography combined with mass spectrometry is the most commonly used detection technology, and it offers the advantages of high sensitivity and high selectivity. However, the contents of bisphenols (BPs) in water samples are at the ng/L level. Even if the BPs contents are determined by mass spectrometry, the samples must be pretreated and enriched. A quick, easy, inexpensive, effective, rugged, and safe technique (QuEChERS) can offer advantages such as cost effectiveness and time efficiency. The application of QuEChERS is currently extended to the analysis of contaminants in food and water samples. In this work, QuEChERS coupled with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was proposed for the determination of eight BPs in surface water. Method optimization was carried out in terms of process efficiency (PE), which included the matrix effect (ME) and extraction recovery (RE). First, the water samples were extracted with 10 mL ethyl acetate and cleaned with 50 mg primary secondary amine (PSA) and 50 mg graphitized carbon black (GCB). Then, the organic layer was collected and evaporated to dryness under nitrogen flow (40 ℃). Finally, the extracts were redissolved in 0.5 mL of a methanol-water (1∶1, v/v) mixture and subjected to UPLC-MS/MS analysis. Chromatographic separation was accomplished on a Waters ACQUITY UPLC BEH C18 column (100 mm×2.1 mm, 1.7 µm) with gradient elution. Methanol and 0.1 mmol/L ammonium bicarbonate aqueous solution were used as the mobile phases. The eight BPs were analyzed by MS/MS with negative electrospray ionization (ESI-) and in the multiple reaction monitoring (MRM) mode. The matrix matching external standard method was used for quantitative determination. The eight compounds could be analyzed within 8 min. Under the optimized conditions, the calibration curves showed good linearities for the eight BPs, and the coefficients of determination (R2) were greater than 0.9990. The limits of detection (LODs, S/N=3) and limits of quantification (LOQs, S/N=10) were in the ranges of 0.1-2.3 ng/L and 0.3-6.1 ng/L, respectively. The average recoveries of the eight BPs in river water samples were 78.8%-116.6%, and the corresponding relative standard deviations (RSDs) were 1.8%-9.0% (n=6). This method was applied to the analysis of BPs pollution in Guangyuan section of Jialing river and its tributaries, and widespread pollution was confirmed. The detection rate of BPA was 100% with a content of 6.15-90.03 ng/L, and the detection rate of BPS was 91%, with the contents being in the range not detected (nd) to 4.63 ng/L. The method established in this study allowed for the rapid enrichment and purification of the eight BPs in water. With its advantages of simplicity, rapidness, high sensitivity, and low cost, the method can be used for the rapid determination of trace BPs in surface water such as lake water and river water.


Subject(s)
Solid Phase Extraction , Tandem Mass Spectrometry , Chromatography, High Pressure Liquid , Chromatography, Liquid , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...