Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Cerebrovasc Dis ; 2023 Jul 29.
Article in English | MEDLINE | ID: mdl-37517392

ABSTRACT

OBJECTIVE: In ischemic stroke patients, we compared the use of insertable cardiac monitor (ICM) versus non-ICM methods of cardiac monitoring on the incidence of atrial fibrillation (AF) detection and other clinical outcomes. BACKGROUND: Current guidelines recommend the routine use of 12-lead electrocardiography or Holter monitoring for AF detection after ischemic stroke. Recent randomised controlled trials have investigated the impact of ICM versus non-ICM methods of cardiac monitoring for AF detection in this population. However, precise recommendations for monitoring post-stroke AF are lacking; including the optimal timing, duration, and method of electrocardiography monitoring. METHODS: A systematic search was conducted on Embase and PubMed from database inception until 27 October 2022 to include randomised controlled trials that compared ICM with non-ICM methods of cardiac monitoring for post-stroke AF detection. This yielded 3 randomised controlled trials with a combined cohort of 1231 patients with a recent ischemic stroke. Individual patient data (IPD) was then reconstructed from Kaplan-Meier curves and analysed using the shared-frailty Cox model. An aggregate data meta-analysis was conducted for 1231 patients across all 3 studies for outcomes that could not be reconstructed using IPD. RESULTS: One-stage meta-analysis demonstrated an increase in the hazard ratio (HR 6.01, 95% CI 3.40-10.60; p<0.001) of AF detection in patients undergoing monitoring via ICM compared to standard care. Aggregate data meta analysis revealed a significant increase in initiation of anticoagulation (OR 3.09, 95% CI 2.05 - 4.66; p<0.00001) in the ICM group. However, no significant differences in the incidence of recurrent ischemic stroke, transient ischemic attack or death were found. CONCLUSIONS: In this meta-analysis, we found that the use of ICM increased the detection rate of post-stroke AF and the rate of anticoagulation initiation. However, this did not translate into a reduced incidence of recurrent ischemic stroke.

2.
Scand J Rheumatol ; 51(1): 1-9, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34107851

ABSTRACT

Objectives: To evaluate the effect of a musculoskeletal ultrasound programme (MUSP) applying real-time ultrasonography with reinforcement of findings by a rheumatologist on improving disease-modifying anti-rheumatic drugs (DMARDs) adherence in rheumatoid arthritis (RA).Method: Eligible RA patients with low adherence score (< 6) on the 8-item Morisky Medication Adherence Scale (MMAS-8) were randomized to either an intervention group (receiving MUSP at baseline) or a control group (no MUSP), and followed up for 6 months. Adherence measures (patient-reported and pharmacy dispensing records) and clinical efficacy data were collected. The MUSP's feasibility and acceptability were assessed.Results: Among 132 recruited RA patients, six without baseline visits were excluded; therefore, 126 patients were analysed (62 intervention and 64 control). The primary outcome (proportion of patients with 1 month MMAS-8 score < 6) was significantly smaller (p = 0.019) in the intervention (35.48%) than the control group (56.25%). However, 3 and 6 month adherence and clinical efficacy outcomes were not significantly different between the two groups (all p > 0.05). All 62 patients completed the MUSP (mean time taken, 9.2 min), with the majority reporting moderately/very much improved understanding of their joint condition (71%) and the importance of regularly taking their RA medication(s) (79%). Most patients (90.3%) would recommend the MUSP to another RA patient.Conclusions: The MUSP improved RA patients' DMARDs adherence in the short term and was feasible and well accepted by patients. Future studies could evaluate whether repeated feedback using MUSP could help to sustain the improvement in DMARD adherence in RA patients, and whether this may be clinically impactful and cost-effective.


Subject(s)
Antirheumatic Agents , Arthritis, Rheumatoid , Antirheumatic Agents/therapeutic use , Arthritis, Rheumatoid/diagnostic imaging , Arthritis, Rheumatoid/drug therapy , Cost-Benefit Analysis , Humans , Medication Adherence , Treatment Outcome , Ultrasonography
3.
Clin Radiol ; 75(12): 963.e17-963.e22, 2020 12.
Article in English | MEDLINE | ID: mdl-32938539

ABSTRACT

AIM: To compare thermography with ultrasonography and clinical joint assessment in patients with rheumatoid arthritis (RA). MATERIALS AND METHODS: Thermography and ultrasonography (power Doppler (PD) and grey-scale (GS) joint inflammation scored semi-quantitatively 0-3) were performed sequentially on both hands of 37 RA patients. Using generalised estimating equations analysis, (a) thermographic parameters (TP) were compared between joints based on their PD and GS joint inflammation positivity/negativity status, while (b) TP and ultrasound-detected joint inflammation were compared between joints categorised by their clinical swelling/tenderness status. RESULTS: Comparing PD positive versus negative joints, the differences in mean values (95% CI) for TP including maximum (Tmax), minimum (Tmin), average (Tavg), and Tmax minus Tmin (Tmax-min) temperatures (in °C) were 1.37 (0.86, 1.87), 0.91 (0.46, 1.36), 1.16 (0.67, 1.64), and 0.46 (0.28, 0.64), respectively. Comparing GS positive versus negative joints, the corresponding results for thermography were 1.09 (0.67, 1.52), 0.66 (0.32, 1.00), 0.86 (0.47, 1.26), and 0.45 (0.28, 0.62), respectively. p-Values were all <0.001. The differences in mean values (95% CI) for ultrasound scores, but not for TP, were statistically significant for (a) swollen tender joints (PD: 0.67 [0.39, 0.96], p<0.001; GS: 0.86 [0.54, 1.18], p<0.001) and (b) swollen non-tender joints (PD: 0.46 [0.07, 0.84], p=0.021; GS: 0.83 [0.37, 1.29], p<0.001) when compared to non-swollen non-tender joints. CONCLUSION: Joints in RA patients have significantly higher temperature readings when ultrasound-detected joint inflammation is present. Swollen tender/non-tender joints exhibited a greater degree of ultrasound-detected joint inflammation than non-swollen non-tender joints, although their temperature readings were not significantly higher.


Subject(s)
Arthritis, Rheumatoid/diagnostic imaging , Thermography/methods , Ultrasonography, Doppler/methods , Cross-Sectional Studies , Female , Humans , Male , Middle Aged
6.
Int J Surg Case Rep ; 16: 93-8, 2015.
Article in English | MEDLINE | ID: mdl-26439418

ABSTRACT

UNLABELLED: Retrograde puncture via patent pedal vessels can be attempted in failed antegrade approach for infrapopliteal long chronic total occlusion. However in cases where the pedal vessels are unable to be visualized via duplex ultrasonography or fluoroscopy an open approach offers an additional option to a vascular surgeon for successful recanalization. Our case report highlights 3 cases where successful hybrid open retrograde approach was able to achieve recanalization of long chronic total occlusion. PRESENTATION OF CASES: The three cases in our series presented with critical limb ischaemia. All three cases had undergone duplex imaging of the affected arterial system. As the antegrade approach to cross the lesion failed a retrograde approach was attempted in all 3 cases. However when the usual modality of retrograde puncture via the use of ultrasound or fluoroscopy failed we proceeded with an open approach. DISCUSSION: Retrograde approach usually offers a better chance of successfully crossing a chronic total occlusion lesion. However puncturing a distal vessel successfully and traversing a catheter or guidewire across proves to be a challenge. An open approach offers an additional pathway for puncturing the target vessel when duplex imaging or fluoroscopic guidance fails. CONCLUSION: Open approach is usually attempted as a last resort by many endovascular surgeons. However procedural time, contrast and radiation usage could have been cut short in cases where the distal target vessels pose a technical challenge for approach via a percutaneous method.

7.
Singapore Med J ; 52(9): e184-6, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21947161

ABSTRACT

Radiosynovectomy is a local and minimally invasive radiotherapy for treating various chronic inflammatory arthritis such as rheumatoid arthritis, osteoarthritis and haemophilic arthropathy. In haemophilic arthropathy, it reduces the frequency of haemarthrosis and delays the development of severe joint destruction, which ultimately requires surgical intervention. Its role in warfarin-related haemarthrosis is less clear. Haemarthrosis is an uncommon complication of warfarin use, and anticoagulation may need to be discontinued. We describe yttrium-90 radiosynovectomy use in a 74-year-old man with underlying ischaemic heart disease, atrial fibrillation, previous embolic stroke and recurrent haemarthrosis of an osteoarthritic right knee. Anticoagulation was vital and could not be permanently stopped. Due to continuing anticoagulation, he had multiple hospitalisations with recurrent right knee haemarthrosis. Intraarticular right knee yttrium-90 citrate colloid injection led to a cessation of haemarthrosis for eight months. We examined the available literature for the role of radiosynovectomy in such circumstances.


Subject(s)
Hemarthrosis/chemically induced , Hemarthrosis/complications , Osteoarthritis/complications , Radiotherapy/methods , Warfarin/adverse effects , Aged , Hemarthrosis/radiotherapy , Humans , Knee/pathology , Knee Joint/radiation effects , Magnetic Resonance Imaging/methods , Male , Myocardial Ischemia/complications , Stroke/complications , Synovial Fluid/metabolism , Yttrium Radioisotopes/pharmacology
8.
J Nanosci Nanotechnol ; 8(5): 2568-74, 2008 May.
Article in English | MEDLINE | ID: mdl-18572685

ABSTRACT

Copper films with high density of twin boundaries are known for high mechanical strength with little tradeoff in electrical conductivity. To achieve such a high density, twin lamellae and spacing will be on the nanoscale. In the current study, 10 microm copper films were prepared by pulse electrodeposition with different applied pulse peak current densities and pulse on-times. It was found that the deposits microstructure was dependent on the parameters of pulse plating. Higher energy pulses caused stronger self-annealing effect on grain recrystallization and growth, thus leading to enhanced fiber textures, while lower energy pulses gave rise to more random microstructure in the deposits and rougher surface topography. However in the extremes of pulse currents we applied, the twin densities were not as high as those resulted from the medium or relatively high pulse currents. The highest amount of nanoscale twinning was found to form from a proper degree of self-annealing induced grain structure evolution. The driving force behind the self-annealing is discussed.

9.
Int J Impot Res ; 20(3): 285-94, 2008.
Article in English | MEDLINE | ID: mdl-18075508

ABSTRACT

The authors aimed to study the skin surface bioheat perfusion model described in part I numerically. The influence of each constituent in the determination of surface temperature profile was statistically examined. The theoretically derived data will then be benchmarked with clinically measured data to develop the artificial intelligence system for the diagnosis of erectile dysfunction (ED). The new approach is based on the hypothesis that there exists a constitutive relationship between surface temperature profiles and the etiology of ED. By considering the penis model as a group of reservoirs with irregular cavities, we built a numerical model, simplified to save computational costs while still realistically able to represent the actual for partial differential calculation. Incompressible blood flow was assumed coupled with the classical bioheat transfer equation which was solved using the finite element method. Isotropic homogeneous heat diffusivity was assigned to each tissue layer. The results of simulations were tested for sensitivity analysis and further optimized to obtain the 'best' signal from the simulations using the Taguchi method. Four important parameters were identified and analysis of variance was performed using the 2(n) design (n=number of parameters, in this case, 4). The implications of these parameters were hypothesized based on physiological observations. Our results show that for an optimum signal-to-noise (S/N) ratio, the noise factors (thermal conductivity of skin, A and tunica albuginea, B) must be set high and low, respectively. Hence, at this setting, the signal will be captured based on the perfusion rate of the boundary layer of the sinusoidal space and the blood pressure (perfusion of sinusoidal space, C and blood pressure, D) will be optimal as their S/N ratios (C (low) and D (low)) are larger than the former.


Subject(s)
Erectile Dysfunction/physiopathology , Hemodynamics , Hot Temperature , Penile Erection/physiology , Penis/blood supply , Analysis of Variance , Biomechanical Phenomena , Body Temperature , Erectile Dysfunction/diagnosis , Humans , Male , Models, Theoretical , Penis/physiology , Regional Blood Flow
10.
Lung Cancer ; 40(3): 237-46, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12781422

ABSTRACT

Lung cancer generally carries a poor prognosis and the determinants of survival have been of interest. However, survival estimates in Asian populations are scarce. This study describes survival rates and their determinants in Singapore Chinese women, a primarily non-smoking population. Three hundred and twenty-six Chinese women, diagnosed with primary lung carcinoma in three major hospitals in Singapore between April 1996 and December 1998, were followed up till 31 December 2000. The Kaplan-Meier method was used for survival analysis. Two hundred and eighty (85.7%) died from the disease during follow-up. The median survival time was 0.7 years and the three-year survival was 15.8%. These survival rates are similar to those of Western populations, and they provide a basis for examining trends over time. Age at diagnosis was an independent prognostic factor [adjusted hazard ratio (relative risk) 1.4, 95% confidence intervals (CI) 1.1-1.9 for women above 65 years relative to younger women]. Most (70.5%) tumours were stage III/IV at diagnosis. Three-year survival ranged from 72% among patients with stage I tumours to 7% for stage IV tumours. Overall, there was no survival difference among different histological types in all stages combined. When limited to stages I and II cancers, adenocarcinomas were associated with a better outcome relative to other histological subtypes combined (adjusted relative risk 0.4, 95% CI 0.1-1.0). Smoking was an independent risk factor (adjusted relative risk 1.3, 95% CI 1.0-1.8). Nevertheless, non-smokers comprised 57.4% of this series, highlighting the importance of increased awareness among health professionals and the public that lung cancer is not only a disease of smokers. The high proportion of late-stage tumours in this study and the impact of disease stage on outcome underline the importance of early detection in improving survival of lung cancer.


Subject(s)
Lung Neoplasms/ethnology , Lung Neoplasms/pathology , Neoplasm Staging , Smoking/adverse effects , Adult , Aged , China/ethnology , Epidemiologic Studies , Female , Humans , Middle Aged , Prognosis , Risk Factors , Singapore/epidemiology , Survival Analysis
12.
Disabil Rehabil ; 24(11-12): 607-12, 2002.
Article in English | MEDLINE | ID: mdl-12182800

ABSTRACT

PURPOSE: To explore the development of a speech interface to a virtual world and to consider its relevance for disabled users. METHOD: The system was developed using mainly software that is available at minimal cost. How well the system functioned was assessed by measuring the number of times a group of users with a range of voices had to repeat commands in order for them to be successfully recognized. During an initial session, these users were asked to use the system with no instruction to see how easy this was. RESULTS: Most of the spoken commands had to be repeated less than twice on average for successful recognition. For a set of 'teleportation' commands this figure was higher (2.4), but it was clear why this was so and could easily be rectified. The system was easy to use without instruction. Comments on the system were generally positive. CONCLUSIONS: While the system has some limitations, a virtual world with a reasonably reliable speech interface has been developed almost entirely from software which is available at minimal cost. Improvements and further testing are considered. Such a system would clearly improve access to virtual reality (VR) technologies for those without the skills or physical ability to use a standard keyboard and mouse. It is an example of both assistive technology (AT) and universal design.


Subject(s)
Software Design , Speech Disorders/rehabilitation , User-Computer Interface , Computer Graphics , Cost Savings , Ergonomics/methods , Female , Humans , Male , Sensitivity and Specificity , Software Validation , United Kingdom
13.
Eur J Orthod ; 24(3): 239-49, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12143088

ABSTRACT

This prospective, randomized, cross-over trial was designed to compare the efficacy of a mandibular advancement splint (MAS) with that of nasal continuous positive airway pressure (nCPAP) in patients with obstructive sleep apnoea (OSA). Twenty-four patients (20 males and four females) with mild to moderate OSA (AHI between 10 and 49 events per hour) were enrolled in the study. Each patient used both MAS and nCPAP, with the initial therapy being allocated at random. Treatment periods lasted for two months with a two-week wash-out interval between. Polysomnography was performed prior to the study and after each clinical intervention. Patient and partner questionnaires were used to assess changes in general health and daytime somnolence. The AHI decreased from 22.2 to 3.1 using nCPAP, and to 8.0 using the MAS (P < 0.001 for both devices) and there was no statistically significant difference between the two treatments. The Epworth Sleepiness Score (ESS) fell from 13.4 to 8.1 with nCPAP, and to 9.2 with MAS (P < 0.001), again with no differences between the use of MAS or nCPAP. The questionnaire data showed an improvement in general health scores (P < 0.001) after both treatments, but daytime sleepiness only improved significantly using nCPAP (P < 0.001). Despite this, 17 out of the 21 subjects who completed both arms of the study preferred the MAS. The splints were well tolerated and their efficacy suggests that the MAS may be a suitable alternative to nCPAP in the management of patients with mild or moderate OSA.


Subject(s)
Orthodontic Appliances , Positive-Pressure Respiration , Sleep Apnea, Obstructive/therapy , Adult , Aged , Analysis of Variance , Body Mass Index , Cross-Over Studies , Female , Follow-Up Studies , Health Status , Humans , Male , Matched-Pair Analysis , Middle Aged , Orthodontic Appliance Design , Patient Satisfaction , Polysomnography , Prospective Studies , Sleep Stages/physiology , Sleep, REM/physiology , Statistics, Nonparametric , Surveys and Questionnaires , Treatment Outcome
14.
J R Coll Surg Edinb ; 46(3): 176-7, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11478017

ABSTRACT

Association of gynaecomastia with hyperthyroidism is uncommon but has been well documented in the past. Gynaecomastia in a patient with hyperthyroidism rarely presents as a primary complaint. When this occurs, it may present a diagnostic challenge to the clinician. We present the case of a patient who was referred initially to the breast clinic with bilateral gynaecomastia. Hyperthyroidism was subsequently confirmed and treated; gynaecomastia regressed with return to the euthyroid state.


Subject(s)
Gynecomastia/etiology , Hyperthyroidism/complications , Humans , Hyperthyroidism/diagnosis , Male , Middle Aged
15.
Med Biol Eng Comput ; 39(2): 182-4, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11361244

ABSTRACT

Fibre-optic sensors are used to monitor the force and temperature of dental splints worn by patients suffering from sleep apnoea. Owing to the small size of the sensors, they can be easily embedded within the splint in a way that does not affect the effectiveness of the splint, and, at the same time, are able to indicate whether the splint has been properly worn by the patient. The overall dimensions of the sensor are approximately 0.375 mm thickness, 1 cm length and 3 mm width. The force and temperature sensors are calibrated and found to have sensitivities of better than 0.5 N and 0.1 degrees C, respectively. Trials performed on patients show that the measurement of pressure and temperature is an effective way of monitoring the proper usage of the dental splint by the patients.


Subject(s)
Occlusal Splints , Patient Compliance , Sleep Apnea, Obstructive/therapy , Fiber Optic Technology/instrumentation , Humans , Stress, Mechanical , Temperature
16.
Int J Med Inform ; 61(2-3): 241-6, 2001 May.
Article in English | MEDLINE | ID: mdl-11311678

ABSTRACT

Due to the inability to exchange clinical information among hospitals, continuity of care cannot be maintained and a tremendous amount of medical resource has been wasted. This paper describes an architecture that would facilitate exchange of clinical information among heterogeneous hospital information systems. It is dubbed 'Medical Information Exchange Center' or MIEC as part of a six-year Health Information Network Project hosted by the Department of Health. MIEC was designed so that it is innovative yet technically feasible today. It is convenient for authorized users yet secure enough so people can trust and has minimal impact to participated hospitals. Authorized users will be able to access information through two web-based interfaces directed to physician and non-physician users respectively. Hospitals are connected through a virtual private network to exchange patient information and users need to obtain a private key from the certificate authority in order to securely connect to MIEC. A pilot project was conducted to demonstrate the feasibility of this architecture and the problems encountered were discussed.


Subject(s)
Computer Systems , Health Personnel , Hospital Information Systems , Information Services , Computer Communication Networks , Confidentiality , Continuity of Patient Care , Humans , Interprofessional Relations , Medical Records Systems, Computerized
17.
Ann Acad Med Singap ; 29(1): 108-9, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10748977

ABSTRACT

INTRODUCTION: Burkholderia pseudomallei infection, the great mimicker of infectious diseases, has protean clinical manifestations. CLINICAL PICTURE: A 37-year-old man who presented with community-acquired pneumonia affecting the right upper lobe had unremitting fever. Bronchoscopy showed an endobronchial mass in the right upper lobe bronchus. TREATMENT: Intravenous ceftriaxone and oral erythromycin, with empiric antituberculous treatment added later. This was subsequently switched to intravenous ceftazidime and oral doxycycline after the diagnosis was made. OUTCOME: There was resolution of the endobronchial mass. CONCLUSION: This case illustrates a unique and unreported presentation of melioidosis.


Subject(s)
Bronchial Diseases/diagnosis , Melioidosis/diagnosis , Adult , Anti-Bacterial Agents , Bronchoscopy , Drug Therapy, Combination/therapeutic use , Hemagglutination Tests , Humans , Male , Melioidosis/drug therapy
18.
Ann Acad Med Singap ; 28(2): 205-8, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10497667

ABSTRACT

In areas where tuberculosis is endemic, a positive sputum acid-fast bacilli (AFB) smear is frequently regarded as almost diagnostic of pulmonary tuberculosis (PTB). The main problem arises when the AFB smear is negative. The main aim of this study was to determine the clinical utility of rapid mycobacterial tuberculosis (MTB) detection in bronchoalveolar lavage (BAL) samples by polymerase chain reaction (PCR) in 52 patients who underwent diagnostic bronchoscopy for suspected PTB. These patients had either upper lobe infiltrates (n = 31) or bronchiectasis (n = 21). Mycobacterial culture is usually used as the gold standard of diagnosis. We chose to define active PTB based on positive mycobacterial cultures and/or histological evidence of caseous necrosis and AFB, and/or when there was clinical plus radiological improvement following therapy. We compared AFB smear, respiratory mycobacterial culture, BAL PCR for MTB and clinical active PTB. Four patients who were smear and culture negative had clinical and radiological clearance following anti-tuberculous therapy showing that using mycobacterial culture as a gold standard may have its limitations. When Kappa (a chance-corrected measure of agreement) was calculated for acid-fast bacilli smear and BAL PCR against our definition of active PTB, it was 0.28 (fair agreement) and 0.73 (substantial agreement), respectively. BAL PCR gave a sensitivity, specificity, positive and negative predictive values of 66.7%, 100%, 100% and 88%, respectively, for the group with upper lobe infiltrates. We also demonstrated that BAL for PCR has a good concordance with the final diagnosis of active tuberculosis.


Subject(s)
Bronchiectasis/microbiology , Bronchoalveolar Lavage Fluid/microbiology , Mycobacterium tuberculosis/isolation & purification , Polymerase Chain Reaction , Sputum/microbiology , Tuberculosis, Pulmonary/diagnosis , Adult , Aged , Aged, 80 and over , Antitubercular Agents/therapeutic use , Bacteriological Techniques , Bronchoscopy , Endemic Diseases , Female , Humans , Lung/pathology , Male , Middle Aged , Mycobacterium tuberculosis/genetics , Necrosis , Predictive Value of Tests , Radiography , Sensitivity and Specificity , Tuberculosis, Pulmonary/diagnostic imaging , Tuberculosis, Pulmonary/drug therapy , Tuberculosis, Pulmonary/pathology
19.
Ann Acad Med Singap ; 28(2): 214-6, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10497669

ABSTRACT

We studied the relationship between different ethnic groups, obstructive sleep apnoea (OSA) and ischaemic heart disease. Four hundred and thirty-two inpatients from the medical wards were interviewed. Limited overnight sleep studies were done in 129 of those who had habitual snoring, daytime sleepiness based on an Epworth sleepiness scale of 8 or more, or a large neck size of 40 cm or more. There were 315 Chinese (72.9%), 67 Malays (15.5%), 43 Indians (10%) and 3 from other races (1.4%). The prevalence of OSA was 19.7%, 30% and 12% among the Chinese, Malays and Indians, respectively. The prevalence ratio for OSA was 1.52 in Malays using Chinese patients as the baseline (P = 0.07). The median neck circumference was 37 cm in both racial groups. The median body mass index was 22.7 kg/m2 in Chinese compared to 23.6 kg/m2 in Malays. The median apnoea-hypopnoea index was 22.7, 19.0 and 26.9 events/hour among the Chinese, Malays and Indians, respectively. OSA was independently associated with the prevalence of IHD (adjusted prevalence ratio 1.68; 95% CI: 1.15, 2.46; P = 0.009). The prevalence of ischaemic heart disease (IHD) was 31%, 24% and 28% in Chinese, Malays and Indians, respectively. The prevalence ratio for IHD in Malays compared to Chinese was 0.77. After adjusting for OSA, there was an even greater reduction in the risk of IHD (adjusted prevalence ratio 0.70). This suggests that OSA is a confounder in the relationship between race and ischaemic heart disease.


Subject(s)
Ethnicity , Myocardial Ischemia/ethnology , Sleep Apnea Syndromes/ethnology , Adult , Aged , Body Mass Index , China/ethnology , Confounding Factors, Epidemiologic , Female , Humans , India/ethnology , Malaysia/ethnology , Male , Middle Aged , Neck/anatomy & histology , Prevalence , Risk Factors , Singapore , Sleep Stages , Snoring/ethnology
20.
Eur J Vasc Endovasc Surg ; 18(1): 71-9, 1999 Jul.
Article in English | MEDLINE | ID: mdl-10388643

ABSTRACT

OBJECTIVE: to determine the role of digital photoplethysmography (D-PPG) in the diagnosis of deep-vein thrombosis (DVT), in comparison to the "gold standard" of either contrast ascending venography (ACV) or colour-flow duplex imaging (CFDI). METHOD: prospective study of 100 hospital inpatients (103 legs) referred to the X-ray department for ACV or CFDI with clinically suspected lower limb DVT in a district general hospital. Each patient was assessed by either ACV or CFDI, and D-PPG. RESULTS: thirty-seven limbs were found to have DVT as demonstrated by ACV or CFDI. All patients with a venous refilling time (RT) of greater than 20 s and venous pump (VP) of greater than 35 had a normal ACV or CFDI. Using RT of less than 21 s as the optimal cut-off point, D-PPG achieved a sensitivity of 100%, negative-predictive value of 100%, specificity of 47% and positive-predictive value of 51%. By using VP of less than 36 as the optimal cut-off point, a sensitivity of 100%, a negative-predictive value of 100%, a specificity of 35% and positive-predictive value of 46% were achieved. CONCLUSIONS: these results validate the use of portable D-PPG as a useful screening tool for the diagnosis of clinically suspected lower limb DVT. A positive test requires further confirmation by one of the "gold standard" methods, whereas a negative test effectively excludes DVT.


Subject(s)
Photoplethysmography/methods , Venous Thrombosis/diagnosis , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Phlebography , Prospective Studies , Sensitivity and Specificity , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...