Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 11(1): 11537, 2021 06 02.
Article in English | MEDLINE | ID: mdl-34078980

ABSTRACT

Prolonged use of tight-fitting PPE, e.g., by COVID-19 healthcare workers leads to skin injuries. An important contributor is the shear exerted on the skin due to static friction at the skin-PPE interface. This study aims to develop an optimised wax-oil lubricant that reduces the friction, or shear, in the skin-PPE contact for up to four hours. Lubricants with different wax-oil combinations were prepared using beeswax, paraffin wax, olive oil, and mineral oil. In-vivo friction measurements involving seven participants were conducted by sliding a polydimethylsiloxane ball against the volar forearms to simulate the skin-PPE interface. The maximum static coefficient of friction was measured immediately and four hours after lubricant application. It was found that the coefficient of friction of wax-oil lubricants is mainly governed by the ratio of wax to oil and the thermal stability and morphology of the wax. To maintain long-term lubricity, it is crucial to consider the absorption of oil into the PPE material. The best performing lubricant is a mixture of 20 wt% beeswax, 40 wt% olive oil, and 40 wt% mineral oil, which compared to unlubricated skin, provides 87% (P = 0.0006) and 59% (P = 0.0015) reduction in instantaneous and 4-h coefficient of friction, respectively.


Subject(s)
Lubricants/chemistry , Lubricants/pharmacology , Personal Protective Equipment/adverse effects , Skin/drug effects , Waxes , Adult , COVID-19 , Female , Forearm/physiology , Humans , Male , Mineral Oil/chemistry , Olive Oil/chemistry , Time Factors , Waxes/chemistry
2.
HardwareX ; 9: e00176, 2021 Apr.
Article in English | MEDLINE | ID: mdl-35492040

ABSTRACT

Due to their inability to sustain their own weight, 3D printing materials as soft as human tissues is challenging. Hereby we describe the development of an extrusion additive manufacturing (AM) machine able to 3D print super soft hydrogels with micro-scale precision. By designing and integrating new subsystems into a conventional extrusion-based 3D printer, we obtained hardware that encompasses a range of new capabilities. In particular, we integrated a heated dual nozzle extrusion system and a cooling platform in the new system. In addition, we altered the electronics and software of the 3D printer to ensure fully automatized procedures are delivered by the 3D printing device, and super-soft tissue mimicking parts are produced. With regards to the electronics, we added new devices to control the temperature of the extrusion system. As for the software, the firmware of the conventional 3D printer was changed and modified to allow for the flow rate control of the ink, thus eliminating overflows in sections of the printing path where the direction/speed changes sharply.

3.
PLoS One ; 15(9): e0239363, 2020.
Article in English | MEDLINE | ID: mdl-32970710

ABSTRACT

BACKGROUND: Healthcare workers around the world are experiencing skin injury due to the extended use of personal protective equipment (PPE) during the COVID-19 pandemic. These injuries are the result of high shear stresses acting on the skin, caused by friction with the PPE. This study aims to provide a practical lubricating solution for frontline medical staff working a 4+ hours shift wearing PPE. METHODS: A literature review into skin friction and skin lubrication was conducted to identify products and substances that can reduce friction. We evaluated the lubricating performance of commercially available products in vivo using a custom-built tribometer. FINDINGS: Most lubricants provide a strong initial friction reduction, but only few products provide lubrication that lasts for four hours. The response of skin to friction is a complex interplay between the lubricating properties and durability of the film deposited on the surface and the response of skin to the lubricating substance, which include epidermal absorption, occlusion, and water retention. INTERPRETATION: Talcum powder, a petrolatum-lanolin mixture, and a coconut oil-cocoa butter-beeswax mixture showed excellent long-lasting low friction. Moisturising the skin results in excessive friction, and the use of products that are aimed at 'moisturising without leaving a non-greasy feel' should be prevented. Most investigated dressings also demonstrate excellent performance.


Subject(s)
Coronavirus Infections/complications , Lubricants/therapeutic use , Personal Protective Equipment/adverse effects , Pneumonia, Viral/complications , Skin/injuries , Adult , Betacoronavirus , Biomechanical Phenomena , COVID-19 , Friction , Humans , Male , Medical Staff , Pandemics , SARS-CoV-2
4.
Sci Rep ; 7(1): 16293, 2017 11 24.
Article in English | MEDLINE | ID: mdl-29176756

ABSTRACT

Conventional 3D bioprinting allows fabrication of 3D scaffolds for biomedical applications. In this contribution we present a cryogenic 3D printing method able to produce stable 3D structures by utilising the liquid to solid phase change of a composite hydrogel (CH) ink. This is achieved by rapidly cooling the ink solution below its freezing point using solid carbon dioxide (CO2) in an isopropanol bath. The setup was able to successfully create 3D complex geometrical structures, with an average compressive stiffness of O(1) kPa (0.49 ± 0.04 kPa stress at 30% compressive strain) and therefore mimics the mechanical properties of the softest tissues found in the human body (e.g. brain and lung). The method was further validated by showing that the 3D printed material was well matched to the cast-moulded equivalent in terms of mechanical properties and microstructure. A preliminary biological evaluation on the 3D printed material, coated with collagen type I, poly-L-lysine and gelatine, was performed by seeding human dermal fibroblasts. Cells showed good attachment and viability on the collagen-coated 3D printed CH. This greatly widens the range of applications for the cryogenically 3D printed CH structures, from soft tissue phantoms for surgical training and simulations to mechanobiology and tissue engineering.

6.
Ann Biomed Eng ; 44(8): 2442-2452, 2016 08.
Article in English | MEDLINE | ID: mdl-26666228

ABSTRACT

Phantoms are common substitutes for soft tissues in biomechanical research and are usually tuned to match tissue properties using standard testing protocols at small strains. However, the response due to complex tool-tissue interactions can differ depending on the phantom and no comprehensive comparative study has been published to date, which could aid researchers to select suitable materials. In this work, gelatin, a common phantom in literature, and a composite hydrogel developed at Imperial College, were matched for mechanical stiffness to porcine brain, and the interactions during needle insertions within them were analyzed. Specifically, we examined insertion forces for brain and the phantoms; we also measured displacements and strains within the phantoms via a laser-based image correlation technique in combination with fluorescent beads. It is shown that the insertion forces for gelatin and brain agree closely, but that the composite hydrogel better mimics the viscous nature of soft tissue. Both materials match different characteristics of brain, but neither of them is a perfect substitute. Thus, when selecting a phantom material, both the soft tissue properties and the complex tool-tissue interactions arising during tissue manipulation should be taken into consideration. These conclusions are presented in tabular form to aid future selection.


Subject(s)
Brain , Models, Biological , Needles , Phantoms, Imaging , Animals , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...