Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Shokuhin Eiseigaku Zasshi ; 64(4): 154-160, 2023.
Article in Japanese | MEDLINE | ID: mdl-37673605

ABSTRACT

An inter-laboratory study involving 24 laboratories was conducted to validate the modified analytical method for the migration solution of heptane for the determination of bisphenol A migrating from polycarbonate food processing materials. In this study, two concentrations of samples were blindly coded. Each laboratory determined the analyte (bisphenol A, phenol and p-tert-butylphenol) concentration in each sample according to the established protocol. The obtained values were analyzed statistically using internationally accepted guidelines. Horwitz ratios were calculated based on the reproducibility relative standard deviation (RSDR), which was estimated from the inter-laboratory study, and predicted RSDR, which was calculated using the Horwitz/Thompson equation. Horwitz ratios of the two samples ranged from 0.15 to 0.37 for the three compounds, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results showed that this modified analytical method shows good performance as an analytical method for the migration solution of heptane.


Subject(s)
Heptanes , Phenols , Reproducibility of Results
2.
Shokuhin Eiseigaku Zasshi ; 63(2): 51-61, 2022.
Article in Japanese | MEDLINE | ID: mdl-35650029

ABSTRACT

Migration test of food utensils, containers, and packaging is an important test method for confirming the safety and their compliance to the standards. However, there is little report on inter-laboratory study which was performed to evaluate the entire migration test, including migration operations and quantification. An interlaboratory study was performed participating 22 laboratories using 8 types of model synthetic resin samples containing 10 substances with a wide range of Log Pow values to evaluate the accuracy of the entire migration test. As a result, most of HorRat (r) values met the target criteria (0.3

Subject(s)
Food Contamination , Plastics , Food Contamination/analysis , Food Packaging , Laboratories
3.
Cereb Cortex ; 30(12): 6415-6425, 2020 11 03.
Article in English | MEDLINE | ID: mdl-32766673

ABSTRACT

The origin and life-long fate of quiescent neural stem cells (NSCs) in the adult mammalian brain remain largely unknown. A few neural precursor cells in the embryonic brain elongate their cell cycle time and subsequently become quiescent postnatally, suggesting the possibility that life-long NSCs are selected at an early embryonic stage. Here, we utilized a GFP-expressing lentivirus to investigate the fate of progeny from individual lentivirus-infected NSCs by identifying the lentiviral integration site. Our data suggest that NSCs become specified to two or more lineages prior to embryonic day 13.5 in mice: one NSC lineage produces cells only for the cortex and another provides neurons to the olfactory bulb. The majority of neurosphere-forming NSCs in the adult brain are relatively dormant and generate very few cells, if any, in the olfactory bulb or cortex, and this NSC population could serve as a reservoir that is occasionally reactivated later in life.


Subject(s)
Brain/growth & development , Cell Lineage , Neural Stem Cells/physiology , Animals , Genetic Vectors , Lentivirus/physiology , Mice, Transgenic
4.
Anat Sci Int ; 95(2): 251-257, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31848975

ABSTRACT

Odontoblasts act as dentin formation and sensory receptors. Recently, it was reported that transient receptor potential ankyrin (TRPA) 1, TRP vanilloid (TRPV) 4 and pannexin 1 (PANX-1) play important roles in odontoblast sensory reception. However, it is not known when odontoblasts begin to possess a sense reception function. The aim of this study was to clarify the development of odontoblasts as sense receptors. Sections of mandibular first molars from postnatal day (PN) 0 to PN12 Wistar rats were prepared for hematoxylin-eosin staining. Immunohistochemically, we used anti-dentin sialoprotein (DSP), anti-TRPA1, anti-TRPV4, anti-PANX-1, and anti-neurofilament (NF) antibodies. In addition, we investigated TRPA1 and TRPV4 expression by reverse transcriptional quantitative polymerase chain reaction (RT-qPCR). At PN0, undifferentiated odontoblasts showed no immunoreaction to anti-DSP, anti-TRPA1, anti-TRPV4, or anti-PANX-1 antibodies. However, immunopositive reactions of these antibodies increased during odontoblast differentiation at PN3 and PN6. An immunopositive reaction of the anti-NF antibody appeared in the odontoblast neighborhood at PN12, when the odontoblasts began to form root dentin, and this appeared later than that of the other antibodies. By RT-qPCR, expression of TRPA1 at PN6 was significantly lower than that at PN0 (p < 0.05) and PN3 (p < 0.01). Expression of TRPV4 at PN6 was significantly lower than that at PN0 (p < 0.01) and PN3 (p < 0.01). The results of this study suggest that odontoblasts may acquire sensory receptor function after beginning to form root dentin, when TRPA1, TRPV4, PANX-1 channels, and nerve fibers are completely formed.


Subject(s)
Molar/growth & development , Molar/physiology , Odontoblasts/metabolism , Odontoblasts/physiology , Sensory Receptor Cells , Transient Receptor Potential Channels/physiology , Animals , Immunohistochemistry , Rats , Reverse Transcriptase Polymerase Chain Reaction , Transient Receptor Potential Channels/metabolism
5.
Shokuhin Eiseigaku Zasshi ; 59(1): 55-63, 2018.
Article in Japanese | MEDLINE | ID: mdl-29743469

ABSTRACT

An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.


Subject(s)
Cooking and Eating Utensils , Food Contamination/analysis , Food Packaging , Acetic Acid , Ethanol , Food Contamination/prevention & control , Japan , Laboratories , Solutions , Solvents , Volatilization , Water
6.
Shokuhin Eiseigaku Zasshi ; 59(1): 64-71, 2018.
Article in Japanese | MEDLINE | ID: mdl-29743470

ABSTRACT

An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.


Subject(s)
Cooking and Eating Utensils , Food Contamination/analysis , Food Packaging , Ethanol , Fatty Alcohols , Food Contamination/prevention & control , Japan , Laboratories , Legislation, Food , Octanes , Solutions , Volatilization
7.
J Physiol Sci ; 67(1): 63-70, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27573166

ABSTRACT

Oligodendrocyte precursor cells (OPCs) appear in the late embryonic brain, mature into oligodendrocytes (OLs), and form myelin in the postnatal brain. It has been proposed that early born OPCs derived from the ventral forebrain are eliminated postnatally and late-born OLs predominate in the adult mouse cortex. However, the temporal and regional niche for cortical OL generation, which persists throughout life in adult mammals, remains to be determined. Our recent study provides new insight into self-renewing and multipotent neural stem cells (NSCs). Our results, together with previous studies, suggest that NSCs at the dorsoventral boundary are uniquely specialized to produce myelin-forming OLs in the cortex during a restricted temporal window. These findings may help identify transcription factors or gene expression patterns which confer neural precursors with the characteristic ability of dorsoventral boundary NSCs to differentiate into OLs, and facilitate the development of new strategies for regenerative medicine of the damaged brain.


Subject(s)
Cell Differentiation/physiology , Cerebral Cortex/cytology , Neural Stem Cells/cytology , Oligodendroglia/cytology , Animals , Humans
8.
Shokuhin Eiseigaku Zasshi ; 57(6): 222-229, 2016.
Article in Japanese | MEDLINE | ID: mdl-28025457

ABSTRACT

The Japanese Food Sanitation Law sets a limit on the migration level of caprolactam for food-contacting nylon products. Here, we carried out an interlaboratory study in twenty laboratories to evaluate the performance of the official GC-FID test method and a GC-MS method as an alternative test method to the official method. Each laboratory quantified caprolactam in three test solutions in 20% ethanol as blind duplicates using GC-FID or GC-MS. The official method (GC-FID with absolute calibration) gave trueness, repeatability (RSDr) and reproducibility (RSDr) values of 96-97%, 3.3-5.4% and 4.0-6.7%, respectively. These values met the target criteria (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of the method was further improved by the introduction of heptalactam as an internal standard. As for GC-MS method, some values of the RSDr exceeded 10% when absolute calibration was used. However, when an internal standard was introduced, the trueness, RSDr and RSDr of GC-MS method were all acceptable at 94-96%, 2.0-4.4% and 7.0-9.4%, respectively. Therefore, GC-MS with an internal standard is available as an alternative test method to the official method.


Subject(s)
Caprolactam/analysis , Cooking and Eating Utensils , Food Analysis/methods , Food Packaging , Laboratories , Nylons/chemistry , Chromatography, Gas , Food Safety , Gas Chromatography-Mass Spectrometry , Legislation, Food/standards , Spectrometry, Fluorescence
9.
Shokuhin Eiseigaku Zasshi ; 57(5): 169-178, 2016.
Article in Japanese | MEDLINE | ID: mdl-27784869

ABSTRACT

Using polystyrene, acrylonitrile-styrene resin and acrylonitrile-butadiene-styrene resin pellets as samples, an interlaboratory study was performed to evaluate the volatiles test method, based on the specifications described in the Japanese Food Sanitation Law for food-contacting polystyrene products. The study was conducted with the participation of twenty-one laboratories. Each laboratory quantified the contents of styrene, toluene, ethylbenzene, isopropylbenzene and propylbenzene in three test pellets using GC-FID, GC-MS or headspace-GC-FID. Statistical analysis revealed that the repeatability (RSDr) and reproducibility (RSDr) were 1.0-2.6 and 2.5-5.5% for the GC-FID method. The values of the performance parameters fulfilled the requirements (RSDr: 10%, RSDr: 25%), and the performance is sufficient for specifications testing. The RSDr and RSDr of results obtained using the GC-MS and HS-GC methods were 1.4-7.8 and 4.9-13%(GC-MS), and 2.0-2.6 and 3.3-6.9%(HS-GC-FID), respectively. The quantified levels were similar to those obtained with GC-FID. The study suggests that the GC-MS and HS-GC methods can be employed as alternative methods to the GC-FID method.


Subject(s)
Acrylic Resins/chemistry , Butadienes/chemistry , Cooking and Eating Utensils , Food Packaging , Gas Chromatography-Mass Spectrometry/methods , Polystyrenes/chemistry , Volatile Organic Compounds/analysis , Benzene Derivatives/analysis , Japan , Laboratories , Legislation, Food , Reproducibility of Results , Spectrometry, Fluorescence/methods , Styrene/analysis , Toluene/analysis
10.
Springerplus ; 5(1): 1193, 2016.
Article in English | MEDLINE | ID: mdl-27516931

ABSTRACT

PURPOSE: Acute respiratory distress syndrome is a life-threatening form of respiratory failure without an established pharmacological treatment. Recently, macrolides have been found to be beneficial in cases of acute lung injury, but evidence is limited. MATERIALS AND METHODS: This single-centre retrospective cohort evaluation of hospitalized patients with sepsis-associated acute respiratory distress syndrome aimed to assess the impact of azithromycin on clinical outcomes by using a propensity score analysis. All data were collected prospectively as part of ongoing research on high-resolution computed tomography of acute respiratory distress syndrome. The primary outcome was 60-day mortality; the secondary outcome was the number of ventilator-free days. RESULTS: Twenty-nine of 125 patients with sepsis-associated acute respiratory distress syndrome (23.2 %) received azithromycin within 24 h after acute respiratory distress syndrome diagnosis. After adjusting for potentially confounding covariates, azithromycin use was associated with lower 60-day mortality (hazard ratio, 0.31; 95 % confidence interval, 0.11-082; P = 0.02) and a shorter time to successful discontinuation of mechanical ventilation. CONCLUSIONS: Azithromycin use was associated with decreased mortality and ventilator dependency in patients with sepsis-associated acute respiratory distress syndrome. Further well-designed prospective studies are needed.

11.
J Atheroscler Thromb ; 23(9): 1047-54, 2016 Sep 01.
Article in English | MEDLINE | ID: mdl-27025680

ABSTRACT

AIM: Previous studies have reported that moderate alcohol consumption is protective against cardiovascular disease, but heavy alcohol consumption increases its risk. Endothelial dysfunction is hypothesized to contribute to the development of atherosclerosis and cardiovascular disease. However, few population-based studies have examined a potential effect of alcohol consumption on endothelial function. METHODS: This study included 404 men aged 30-79 years who were recruited from residents in 2 communities under the Circulatory Risk in Communities Study in 2013 and 2014. We asked the individuals about the frequency and volume of alcohol beverages and converted the data into grams of ethanol per day. Endothelial function was assessed by brachial artery flow-mediated dilation (FMD) measurements during reactive hyperemia. We performed cross-sectional analysis of alcohol consumption and %FMD by logistic regression analysis, adjusting for age, baseline brachial artery diameter, body mass index, systolic blood pressure, low-density lipoprotein cholesterol, HbA1c, smoking, antihypertensive medication use, and community. RESULTS: Individuals who drank ≥ 46 g/day ethanol had a lower age-adjusted mean %FMD than non-drinkers (p<0.01). Compared with non-drinkers, the age-adjusted odds ratios (ORs) (95% confidence interval) of low %FMD (<5.3%) for former, light (<23.0 g/day ethanol), moderate (23.0-45.9 g/day ethanol), and heavy (≥ 46.0 g/day ethanol) drinkers were 1.61 (0.67-3.89), 0.84 (0.43-1.66), 1.09 (0.52-2.25), and 2.99 (1.56-5.70), respectively. The corresponding multivariable-adjusted ORs were 1.76 (0.69-4.50), 0.86 (0.42-1.76), 0.98 (0.45-2.12), and 2.39 (1.15-4.95), respectively. CONCLUSIONS: Heavy alcohol consumption may be an independent risk factor of endothelial dysfunction in Japanese men.


Subject(s)
Alcohol Drinking/adverse effects , Coronary Disease/etiology , Endothelial Cells/pathology , Adult , Aged , Cholesterol, HDL/analysis , Cholesterol, LDL/analysis , Cohort Studies , Cross-Sectional Studies , Endothelial Cells/drug effects , Humans , Male , Middle Aged , Risk Factors
12.
Chem Pharm Bull (Tokyo) ; 63(11): 935-44, 2015.
Article in English | MEDLINE | ID: mdl-26521858

ABSTRACT

As one of our projects, we here report some new molecular modifications of 2,4,6-trichloro-1,3,5-triazine (TCTAZ: 1) to symmetrical 2,4,6-trialkoxy- or 2,4,6-triaryloxy-substituted 1,3,5-triazine (TAZ) molecules, as well as the results of anti-herpes simplex virus type 1 (anti-HSV-1) activity evaluation of synthesized 2,4,6-trisubstituted TAZ derivatives. Among the tested 2,4,6-trisubstituted TAZ derivatives, we reconfirmed that a C3-symmetrical TAZ derivative, 4e, shows the highest level of anti-HSV-1 activity with a good selectivity index. In this paper, we also report the results of the preparation of newly targeted TAZ derivatives and the structure-activity relationships (SARs) of these trialkoxy-substituted TAZ derivatives and related compounds. The sugar recognition properties of C3-symmetrical TAZ derivative 4e are also described.


Subject(s)
Antiviral Agents/chemistry , Antiviral Agents/pharmacology , Herpes Simplex/drug therapy , Herpesvirus 1, Human/drug effects , Triazines/chemistry , Triazines/pharmacology , Animals , Antiviral Agents/chemical synthesis , Chlorocebus aethiops , Humans , Structure-Activity Relationship , Triazines/chemical synthesis , Vero Cells
13.
Shokuhin Eiseigaku Zasshi ; 56(3): 123-31, 2015.
Article in Japanese | MEDLINE | ID: mdl-26156169

ABSTRACT

Using six kinds of zinc solution in water and 4% acetic acid as samples, an interlaboratory study was performed to evaluate a zinc (Zn) test method for food-contact rubber products, based on the Japanese Food Sanitation Law. Eighteen laboratories participated, and quantified Zn in six test solutions as blind duplicates using flame atomic absorption spectrometry, induced coupled plasma-optical emission spectrometry or induced coupled plasma-mass spectrometry. Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 97-103%, 0.7-4.9% and 1.7-8.9% by all measuring methods. The values of the performance parameter fulfilled the target value (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of these methods is sufficient for testing the adherence of samples to the specifications.


Subject(s)
Cooking and Eating Utensils , Food Analysis/methods , Food Contamination/analysis , Food Packaging , Hazard Analysis and Critical Control Points/methods , Mass Spectrometry/methods , Rubber/chemistry , Spectrophotometry, Atomic/methods , Zinc/analysis , Feasibility Studies , Food Safety , Reproducibility of Results , Solutions
14.
Shokuhin Eiseigaku Zasshi ; 56(2): 57-67, 2015.
Article in Japanese | MEDLINE | ID: mdl-25925077

ABSTRACT

An interlaboratory study was performed to evaluate a migration test method of antimony (Sb) and germanium (Ge), based on the Japanese Food Sanitation Law for food- contact polyethylene terephthalate. Eighteen laboratories participated, and quantified Sb and Ge in three test solutions as blind duplicates using graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability and reproducibility were 98-107%, 1.7-7.5% and 2.0-18.8% by using GF-AAS and ICP-OES. The performance of these methods is sufficient for testing the specifications. The performance parameters of ICP-MS were 99-106%, 0.7-2.2% and 2.2-10.5%, respectively. ICP-MS is available as an alternative measuring method. However, in some laboratories, the quantitative values of Sb were higher than the addition levels. We found that Sb in working solutions is absorbed on glass vessels. Careful control of concentration in working solutions is required for Sb analysis.


Subject(s)
Antimony/analysis , Cooking and Eating Utensils , Food Packaging , Germanium/analysis , Hazard Analysis and Critical Control Points/methods , Laboratories/standards , Polyethylene Terephthalates/chemistry , Food Safety , Japan , Legislation, Food , Mass Spectrometry , Reproducibility of Results , Solutions , Spectrophotometry, Atomic
15.
Shokuhin Eiseigaku Zasshi ; 55(2): 117-34, 2014.
Article in Japanese | MEDLINE | ID: mdl-24990558

ABSTRACT

An interlaboratory study was performed to evaluate a migration test method of cadmium (Cd) and lead (Pb), based on the Japanese Food Sanitation Law for glassware, ceramicware, enamelware and metal cans. Seventeen laboratories participated, and quantified Cd and Pb in eight test solutions as blind duplicates using flame atomic absorption spectrometry (AAS), graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 93-105%, 0.7-8.4% and 2.6-19.3% by using AAS, ICP-OES and ICP-MS (internal standard method). The performance of these methods is sufficient for testing specifications. However, some of the RSDr values exceeded 10% in GF-AAS, and careful control of accuracy is required.


Subject(s)
Cadmium/analysis , Cooking and Eating Utensils/legislation & jurisprudence , Cooking and Eating Utensils/standards , Food Contamination/prevention & control , Food Packaging/legislation & jurisprudence , Food Packaging/standards , Laboratories/standards , Lead/analysis , Legislation, Food/standards , Mass Spectrometry/methods , Spectrophotometry, Atomic/methods , Acetic Acid , Citric Acid , Reproducibility of Results , Sensitivity and Specificity , Solutions , Water
16.
Shokuhin Eiseigaku Zasshi ; 55(6): 269-78, 2014.
Article in Japanese | MEDLINE | ID: mdl-25743590

ABSTRACT

Based on the Japanese Food Sanitation Law, the performances of official and alternative material test methods for cadmium (Cd) and lead (Pb) in food contact plastics were compared. Nineteen laboratories participated to an interlaboratory study, and quantified Cd and Pb in three PVC pellets. in the official method, a sample is digested with H2SO4, taken up in HCl, and evaporated to dryness on a water bath, then measured by atomic absorption spectrometry (AAS) or inductively coupled plasma-optical emission spectrometry (ICP-OES). Statistical treatment revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 86-95%, 3.1-9.4% and 8.6-22.1%, respectively. The values of the performance parameters fulfilled the requirements , and the performances met the test specifications. The combination of evaporation to dryness on a hot plate and measurement by AAS or ICP-OES is applicable as an alternative method. However, the trueness and RSDr were inferior to those of the official method. The performance parameters obtained by using the microwave digestion method (MW method) to prepare test solution were better than those of the official method. Thus, the MW method is available as an alternative method. Induced coupled plasma-mass spectrometry (ICP-MS) is also available as an alternative method. However, it is necessary to ensure complete digestion of the sample.


Subject(s)
Cadmium/analysis , Cooking and Eating Utensils , Food Packaging , Lead/analysis , Mass Spectrometry/methods , Polyvinyl Chloride/analysis , Polyvinyl Chloride/chemistry , Spectrophotometry, Atomic/methods , Cadmium/isolation & purification , Lead/isolation & purification , Microwaves
17.
BMJ Open ; 3(9): e003354, 2013 Sep 10.
Article in English | MEDLINE | ID: mdl-24022391

ABSTRACT

OBJECTIVES: To determine (1) the proportion and number of clinically relevant alarms based on the type of monitoring device; (2) whether patient clinical severity, based on the sequential organ failure assessment (SOFA) score, affects the proportion of clinically relevant alarms and to suggest; (3) methods for reducing clinically irrelevant alarms in an intensive care unit (ICU). DESIGN: A prospective, observational clinical study. SETTING: A medical ICU at the University of Tokyo Hospital in Tokyo, Japan. PARTICIPANTS: All patients who were admitted directly to the ICU, aged ≥18 years, and not refused active treatment were registered between January and February 2012. METHODS: The alarms, alarm settings, alarm messages, waveforms and video recordings were acquired in real time and saved continuously. All alarms were annotated with respect to technical and clinical validity. RESULTS: 18 ICU patients were monitored. During 2697 patient-monitored hours, 11 591 alarms were annotated. Only 740 (6.4%) alarms were considered to be clinically relevant. The monitoring devices that triggered alarms the most often were the direct measurement of arterial pressure (33.5%), oxygen saturation (24.2%), and electrocardiogram (22.9%). The numbers of relevant alarms were 12.4% (direct measurement of arterial pressure), 2.4% (oxygen saturation) and 5.3% (electrocardiogram). Positive correlations were established between patient clinical severities and the proportion of relevant alarms. The total number of irrelevant alarms could be reduced by 21.4% by evaluating their technical relevance. CONCLUSIONS: We demonstrated that (1) the types of devices that alarm the most frequently were direct measurements of arterial pressure, oxygen saturation and ECG, and most of those alarms were not clinically relevant; (2) the proportion of clinically relevant alarms decreased as the patients' status improved and (3) the irrelevance alarms can be considerably reduced by evaluating their technical relevance.

SELECTION OF CITATIONS