Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Exp Orthop ; 11(2): e12015, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38590755

ABSTRACT

Purpose: The optimal hinge position to prevent hinge fractures in medial closing wedge distal femoral osteotomy (MCWDFO) based on the biomechanical background has not yet been well examined. This study aimed to examine the appropriate hinge position in MCWDFO using finite element (FE) analysis to prevent hinge fractures. Methods: Computer-aided design (CAD) models were created using composite replicate femurs. FE models of the MCWDFO with a 5° wedge were created with three different hinge positions: (A) 5 mm proximal to the proximal margin of the lateral epicondylar region, (B) proximal margin level and (C) 5 mm distal to the proximal margin level. The maximum and minimum principal strains in the cortical bone were calculated for each model. To validate the FE analysis, biomechanical tests were performed using composite replicate femurs with the same hinge position models as those in the FE analysis. Results: In the FE analysis, the maximum principal strains were in the order of Models A > B > C. The highest value of maximum principal strain was observed in the area proximal to the hinge. In the biomechanical test, hinge fractures occurred in the area proximal to the hinge in Models A and B, whereas the gap closed completely without hinge fractures in Model C. Fractures occurred in an area similar to where the highest maximal principal strain was observed in the FE analysis. Conclusion: Distal to the proximal margin of the lateral epicondylar region is an appropriate hinge position in MCWDFO to prevent hinge fractures. Level of Evidence: Level V.

2.
Cureus ; 16(1): e53228, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38425608

ABSTRACT

Cementless unicompartmental knee arthroplasty (UKA) has a lower rate of radiolucency in postoperative follow-up than cemented UKA. However, the rate of tibial plateau fracture, one of the complications, has been reported to be higher in cementless UKA than in cemented UKA. We report four cases of postoperative tibial lateral condyle fractures after cementless Oxford UKA. Four patients underwent cementless Oxford UKA. Immediate postoperative radiography and CT showed no fracture lines. At five to six weeks postoperatively, MRI showed a fracture line from the intersection of the longitudinal and transverse tibial osteotomies through the lateral pinhole to the end of the lateral tibial diaphysis. At three months, bone union was observed without surgical treatments. Lateral tibial fracture after cementless Oxford UKA has a good clinical course without the need for surgical intervention. Medial fractures should thus be more actively prevented. MRI is useful for less symptomatic tibial lateral condyle fractures.

3.
Cureus ; 15(7): e41349, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37546044

ABSTRACT

Background For successful internal fixation for femoral neck fracture, the sliding mechanism of the screw is important because it can induce inter-fragmental compression. The thread should penetrate the fracture line and be located within the proximal fragment. If screw thread engagement is incomplete and a part of the thread remains within the distal fragment, the screw sliding can be disturbed, potentially leading to fixation failure. We hypothesized that screw thread in the fracture is a risk of fixation failure. Methods We studied 133 hips that underwent internal fixation for femoral neck fracture using dual sliding and compression screws (DSCS) with 20 mm threads. The existence of incomplete thread engagement and fixation failure (cut out, perforation, pseudoarthrosis, or femoral neck shortening) were evaluated on anteroposterior hip radiography postoperatively. The distances from the thread end to the fracture line, screw head to the femoral head cortex, and femoral head diameter were measured to analyze their relationships with any incomplete thread engagement and fixation failure. Differences in evaluation data were assessed using Fisher's exact test, Student's t-test, and receiver operating characteristic (ROC) analysis. Results Forty-six cases had at least one screw with incomplete thread engagement, and the other 87 hips had a complete engagement. The failure rate in the group of hips with incomplete thread engagement was significantly higher (7/46, 15.2%) than that in the group of hips with complete thread engagement (3/87, 3.4%) (P = 0.032). Incomplete thread engagement was found in 59 out of 266 screws (22.2%), and a femoral head ≤ 43.9 mm in diameter was associated with an increased risk of incomplete thread engagement. Most incomplete thread engagement screws (81.4%) had < 5 mm thread length within the distal fragment. Conclusion A partially threaded screw is a significant risk of fixation failure after internal fixation for a femoral neck fracture. The smaller femoral head diameter increases the possibility of incomplete thread engagement. Shortening the thread length by 5 mm may help to avoid incomplete thread engagement.

4.
Knee ; 40: 220-226, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36512893

ABSTRACT

BACKGROUND: Unicompartmental knee arthroplasty (UKA) can provide good postoperative results and long term survival, but there may be complications. We present a rare case of avulsion fracture of the intercondylar eminence during UKA surgery. CASE PRESENTATION: An 88-year-old man had right-knee pain with anteromedial osteoarthritis. Oxford partial knee UKA (Zimmer Biomet, Warsaw, IN) was performed by the senior author by the under-vastus approach using Microplasty instruments. During the final check of the range of motion, an avulsion fracture of the intercondylar eminence occurred at the terminal extension. A 4.0 mm cannulated cancellous screw was inserted into the intercondylar eminence from just in front of the anterior cruciate ligament to the posterior tibial cortex. Six months postoperatively, bony fusion was confirmed by lateral radiography. Two years after the surgery, the patient was fully satisfied. The flexion angle was 125°, but still with an extension limit of 10°. DISCUSSION: Avulsion fracture of the intercondylar eminence can be caused by hyperextension and/or the ACL becoming tighter in full extension of the knee. In this patient, avulsion fracture also probably occurred due to increased tension of the ACL in the fully extended position. After making the horizontal cut, we inserted a thin metal plate to prevent deeper vertical cuts, but an excessive horizontal cut was a possible cause of the fracture. As treatment for avulsion fracture of the intercondylar eminence, fixation of the cannulated cancellous screw resulted in uneventful bone fusion. We recommend having a cannulated cancellous screw at hand for such complications and for other potential intraoperative problems, such as tibial plateau fracture. Further investigation into limited postoperative extension might be needed. CONCLUSION: Our patient had intraoperative avulsion fracture of the intercondylar eminence, a relatively rare complication of Oxford UKA which is probably caused by the extension being tight and/or an excessive horizontal cut. Having a cannulated cancellous screw at hand is advised, and attention should be paid to postoperative limit of extension.


Subject(s)
Arthroplasty, Replacement, Knee , Fractures, Avulsion , Joint Diseases , Tibial Fractures , Male , Humans , Aged, 80 and over , Fractures, Avulsion/diagnostic imaging , Fractures, Avulsion/surgery , Arthroscopy/methods , Anterior Cruciate Ligament/surgery , Knee Joint/surgery , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , Joint Diseases/surgery
5.
Bone Jt Open ; 3(5): 390-397, 2022 May.
Article in English | MEDLINE | ID: mdl-35532356

ABSTRACT

The kinematic alignment (KA) approach to total knee arthroplasty (TKA) has recently increased in popularity. Accordingly, a number of derivatives have arisen and have caused confusion. Clarification is therefore needed for a better understanding of KA-TKA. Calipered (or true, pure) KA is performed by cutting the bone parallel to the articular surface, compensating for cartilage wear. In soft-tissue respecting KA, the tibial cutting surface is decided parallel to the femoral cutting surface (or trial component) with in-line traction. These approaches are categorized as unrestricted KA because there is no consideration of leg alignment or component orientation. Restricted KA is an approach where the periarthritic joint surface is replicated within a safe range, due to concerns about extreme alignments that have been considered 'alignment outliers' in the neutral mechanical alignment approach. More recently, functional alignment and inverse kinematic alignment have been advocated, where bone cuts are made following intraoperative planning, using intraoperative measurements acquired with computer assistance to fulfill good coordination of soft-tissue balance and alignment. The KA-TKA approach aims to restore the patients' own harmony of three knee elements (morphology, soft-tissue balance, and alignment) and eventually the patients' own kinematics. The respective approaches start from different points corresponding to one of the elements, yet each aim for the same goal, although the existing implants and techniques have not yet perfectly fulfilled that goal.

7.
Knee ; 35: 54-60, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35220133

ABSTRACT

BACKGROUND: Restricted kinematically-aligned total knee arthroplasty (KA-TKA) is a reasonable modification to avoid the alignment outlier that may cause implant failure. However, despite a noted high incidence of constitutional varus in Japanese individuals, there has been no investigation into how many knees require the restriction in restricted KA-TKA (RKA-TKA) among Japanese patients. Therefore, we conducted a study using preoperative long-leg radiograms. METHODS: We studied long-leg radiographs of 228 knees in 114 consecutive patients. The numbers of knees within the safety range and their corrective osteotomy angle in the restriction algorithms advocated by Almaawi et al. (2017) and MacDessi et al. (2020) were evaluated. RESULTS: According to the algorithms used by Almaawi et al. and MacDessi et al., out of 228 knees, 46 (20%) and 39 (17%) fell within the safety range, respectively. The mean correction angles of the hip-knee-ankle angle, lateral distal femoral angle and medial proximal tibial angle were 2.8 ± 3.4°, 0.4 ± 1.4° and 2.4 ± 2.8° in the algorithm used by Almaawi et al., while they were -4.9 ± 4.7°, 1.1 ± 2.5° and -6.0 ± 3.4° in the algorithm used by MacDessi et al. Most of the knees needed to be restricted in order to perform RKA-TKA, regardless of the algorithm used. CONCLUSIONS: Based on a preoperative analysis of long-leg radiograms in a Japanese population, most knees fall out of the safety range in RKA-TKA. Surgeons must consider whether to allow component outlier or to perform corrective osteotomy that likely requires soft tissue release.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Arthroplasty, Replacement, Knee/adverse effects , Biomechanical Phenomena , Humans , Japan/epidemiology , Knee Joint/diagnostic imaging , Knee Joint/surgery , Leg/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery
8.
J Arthroplasty ; 37(5): 942-947, 2022 05.
Article in English | MEDLINE | ID: mdl-35074447

ABSTRACT

BACKGROUND: Bearing dislocation is a serious complication after Oxford unicompartmental knee arthroplasty. Bearing separation from the lateral wall can cause it to spin (90° horizontal rotation) and eventually dislocate because there is just a 2 mm difference in height in both the lateral and medial sides from the bottom of the bearing, compared with the anterior (5 mm) and posterior (3 mm) sides. The details of this problem have not been previously examined. METHODS: Twenty-one dislocations in 12 patients were retrospectively analyzed. Bearing separation was defined as the bearing position being sufficiently distant from the lateral wall of the tibial component to allow spinning. We analyzed the incidence of separation, the direction and the recurrence of the dislocations, and their causes and treatments. RESULTS: Five of the 12 patients had separation. Of the total of 21 dislocations, 11 occurred in cases of separation (52%). Seven of 11 anterior dislocations were found to have separation, whereas nine of 13 posterior dislocations occurred without separation (P = .0237). Three of 5 patients with separation had recurrence of dislocation, and eventually 2 underwent revision to fixed-bearing unicompartmental knee arthroplasty. CONCLUSION: Bearing separation from the lateral wall of the tibial component can cause bearing dislocation, especially in an anterior direction. To prevent separation, the wall-bearing distance should be evaluated before the keel slot preparation, with manipulation as necessary. Conversely, posterior dislocation was predominant in our nonseparation cases.


Subject(s)
Arthroplasty, Replacement, Knee , Joint Dislocations , Knee Prosthesis , Osteoarthritis, Knee , Arthroplasty, Replacement, Knee/adverse effects , Humans , Joint Dislocations/surgery , Knee Joint/surgery , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/etiology , Osteoarthritis, Knee/surgery , Retrospective Studies , Tibia/surgery
9.
Hip Int ; 30(2_suppl): 86-93, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33267694

ABSTRACT

INTRODUCTION: The aim of this study was to investigate the mechanisms of periprosthetic fractures occurring as a result of a sideways fall in total hip arthroplasty patients, and to compare the predictions of numerical models in terms of load distribution on the implanted femur with clinical data. MATERIALS AND METHODS: 3 numerical models were built: 1 for intact femur and 2 for implanted femur with a straight stem (resembling PBF, Permedica) and with an anatomical stem (resembling ABG II, Stryker). 4 loading configurations were simulated; 1 simulates a vertical load, and 3 simulate a fall with impact on the greater trochanter in different directions. Stress state calculated in the implanted femur was compared for the 2 models with reference to the intact case. These were compared with clinical data collected at a single centre (Istituto Ortopedico Gaetano Pini, Milan, Italy) where 41 patients were investigated after periprosthetic fracture: 26 patients had a straight uncemented stem and 15 an anatomical uncemented stem. RESULTS: The maximum calculated strain in compression in the case of ABG II implanted femur was 2 times higher than in the presence of PBF stem in the vertical loading configuration. For configurations of sideways fall, in both models, there was a progressive increase of stress state in the bone with increasing angle. Simulations of sideways fall elicited results in accordance with clinical observations: due to the peculiar stem design and consequent state of stress in the bone, anatomical stems seem to induce trochanteric fractures more frequently, while for straight stems type B fractures are more likely to occur. CONCLUSIONS: Clinical findings confirmed numerical model predictions: stem design seems to highly influence distribution of stress in the bone and consequent localisation of the fracture site.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Periprosthetic Fractures , Arthroplasty, Replacement, Hip/adverse effects , Femoral Fractures/etiology , Femoral Fractures/surgery , Femur/diagnostic imaging , Femur/surgery , Humans , Italy , Periprosthetic Fractures/diagnostic imaging , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery
10.
Biochim Biophys Acta Proteins Proteom ; 1868(11): 140496, 2020 11.
Article in English | MEDLINE | ID: mdl-32673742

ABSTRACT

Structural alterations of aspartyl and asparaginyl residues in various proteins can lead to their malfunction, which may result in severe health disorders. The formation and hydrolysis of succinimidyl intermediates are crucial in specific protein modifications. Nonetheless, only few studies investigating the hydrolysis of succinimidyl intermediates have been published. In this study, we established a method to prepare peptides bearing succinimidyl residues using recombinant protein l-isoaspartyl methyltransferase and ultrafiltration units. Using succinimidyl peptides, we examined the effect of amino acid residues on succinimidyl hydrolysis at the carboxyl end of succinimidyl residues and determined the rate constant of hydrolysis for each peptide. The rate constant of succinimidyl hydrolysis in the peptide bearing a Ser residue at the carboxyl side (0.50 ± 0.02 /h) was 3.0 times higher than that for the peptide bearing an Ala residue (0.17 ± 0.01 /h), whereas it was just 1.2 times higher for the peptide bearing a Gly residue (0.20 ± 0.01 /h). The rate constant of succinimidyl formation in the peptide bearing a Ser residue [(2.44 ± 0.11) × 10-3 /d] was only 1.2 times higher than that for the peptide bearing an Ala residue ([1.87 ± 0.09) × 10-3 /d], whereas 5.5 times higher for the peptide bearing a Gly residue [(10.2 ± 0.2) × 10-3 /d]. These results show that the Gly and Ser residues at the carboxyl end of the succinimidyl residue have opposing roles in succinimidyl formation and hydrolysis. Catalysis of Ser residue's hydroxyl group plays a crucial role in succinimidyl hydrolysis.


Subject(s)
Amino Acids/metabolism , Oligopeptides/metabolism , Protein D-Aspartate-L-Isoaspartate Methyltransferase/metabolism , Succinimides/metabolism , Amino Acids/chemistry , Escherichia coli/genetics , Hydrolysis , Protein D-Aspartate-L-Isoaspartate Methyltransferase/chemistry , Protein D-Aspartate-L-Isoaspartate Methyltransferase/genetics , Recombinant Proteins/chemistry , Recombinant Proteins/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...