Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
1.
Cureus ; 16(6): e61558, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38962648

ABSTRACT

Hip dislocation is rare, and it typically results from high-energy trauma such as traffic accidents. Its management involves prompt reduction of the dislocated hip to minimize the risk of subsequent femoral head necrosis. Consequently, cases of chronic hip dislocation are extremely rare. This report presents a case of a 33-year-old male with chronic posterior hip dislocation due to a traffic accident 13 years ago. The left femoral head was completely dislocated posteriorly from the acetabulum, forming a false acetabulum with an arthritic change. The patient experienced difficulty walking and performing daily activities due to pain. We performed a total hip arthroplasty (THA) using a combined anterolateral and posterior approach. The outcome was favorable, with no complications during the two-year follow-up period. THA using a combined anterolateral and posterior approach is a valuable option for patients with chronic post-traumatic hip dislocation because it offers the advantages of optical visibility and the management of the adhered soft tissues.

2.
J Orthop Sci ; 2024 Feb 10.
Article in English | MEDLINE | ID: mdl-38342711

ABSTRACT

BACKGROUND: Periprosthetic bone loss following total hip arthroplasty (THA) threatens prosthesis stability. This systematic review and network meta-analysis aimed to compare the efficacy of anti-osteoporotic drugs for measures of hip function according to functional outcomes, periprosthetic femoral bone mineral density loss in each Gruen zone, and revision surgery after THA. METHODS: The systematic search of six literature databases was conducted in December 2021 in accordance with PRISMA guidelines. Adult participants who underwent primary THA were included. A random-effects network meta-analysis was performed within a frequentist framework, and the confidence in the evidence for each outcome was evaluated using the CINeMA tool, which assessed the credibility of results from the network meta-analysis. We included 22 randomized controlled trials (1243 participants) comparing the efficacy and safety of bisphosphonates (including etidronate, clodronate, alendronate, risedronate, pamidronate, and zoledronate), denosumab, selective estrogen receptor modulator, teriparatide, calcium + vitamin D, calcium, and vitamin D. We defined the period for revision surgery as the final follow-up period. RESULTS: Raloxifene, bisphosphonate, calcium + vitamin D, and denosumab for prosthetic hip function might have minimal differences when compared with placebos. The magnitude of the anti-osteoporotic drug effect on periprosthetic femoral bone loss varied across different Gruen zones. Bisphosphonate, denosumab, teriparatide might be more effective than placebo in Gruen zone 1 at 12 months after THA. Additionally, bisphosphonate might be more effective than placebo in Gruen zones 2, 5, 6, and 7 at 12 months after THA. Denosumab was efficacious in preventing bone loss in Gruen zones 6 and 7 at 12 months after THA. Teriparatide was likely to be efficacious in preventing bone loss in Gruen zone 7 at 12 months after THA. Raloxifene was slightly efficacious in preventing bone loss in Gruen zones 2 and 3 at 12 months after THA. Calcium was slightly efficacious in preventing bone loss in Gruen zone 5 at 12 months after THA. None of the studies reported revision surgery. CONCLUSIONS: Bisphosphonate and denosumab may be effective anti-osteoporotic drugs for preventing periprosthetic proximal femoral bone loss due to stress shielding after THA, particularly in cementless proximal fixation stems, which are the most commonly used prostheses worldwide.

3.
BMC Musculoskelet Disord ; 24(1): 388, 2023 May 16.
Article in English | MEDLINE | ID: mdl-37194069

ABSTRACT

BACKGROUND: While fear of movement is an important predictor of pain and disability in osteoarthritis (OA), its impact on patients with hip OA remains uncertain. This study aimed to determine whether fear of movement, evaluated by the Tampa Scale for Kinesiophobia (TSK)-11, and pain catastrophizing, evaluated by the Pain Catastrophizing Scale (PCS), were associated with quality of life (QOL) in patients with hip OA. METHODS: This cross-sectional study was conducted between November 2017 and December 2018. Ninety-one consecutively enrolled patients with severe hip OA were scheduled for primary unilateral total hip arthroplasty. The EuroQOL-5 Dimensions questionnaire was used to measure general QOL. The Japanese Orthopedic Association Hip Disease Evaluation Questionnaire was used to assess disease-specific QOL. The covariates included age, sex, body mass index (BMI), pain intensity, high pain catastrophizing (PCS ≥ 30), and high kinesiophobia (TSK-11 ≥ 25). Variables were subjected to multivariate analysis using each QOL scale. RESULTS: In multiple regression analysis, pain intensity, high pain catastrophizing, and BMI were independently correlated with the disease-specific QOL scale. High pain catastrophizing, pain intensity, and high kinesiophobia were independently correlated with the general QOL scale. CONCLUSIONS: High pain catastrophizing (PCS ≥ 30) was independently associated with disease and general QOL scales. High kinesiophobia (TSK-11 ≥ 25) was independently associated with the general QOL scale in preoperative patients with severe hip OA.


Subject(s)
Osteoarthritis, Hip , Humans , Osteoarthritis, Hip/complications , Osteoarthritis, Hip/surgery , Kinesiophobia , Cross-Sectional Studies , Quality of Life , Catastrophization , Pain
4.
Medicina (Kaunas) ; 58(7)2022 Jun 27.
Article in English | MEDLINE | ID: mdl-35888575

ABSTRACT

Background and Objectives: Precise acetabular cup placement is essential for successful total hip arthroplasty (THA). In obese patients, its accuracy is often difficult to achieve because of the thickness of the soft tissues. This study aimed to determine the relationship between the accuracy of acetabular cup angle and body mass index (BMI) in posterolateral THA using the computed tomography-based navigation (CT-navi) system. Materials and Methods: We retrospectively reviewed 145 consecutive primary THAs using the CT-navi system between January 2015 and January 2018. All surgeries were performed using cementless cups employing the posterolateral approach with the patient in the decubitus position. We compared the radiographic inclination and anteversion obtained intraoperatively from the CT-navi with those measured by postoperative CT using three-dimensional templating software. We evaluated the relationship between the extent of errors and correlation with BMI. Results: In non-overweight patients (BMI < 25, 88 hips), the mean navigation errors for inclination were 2.8 ± 2.2° and for anteversion were 2.6 ± 2.3°. Meanwhile, in overweight patients (BMI ≥ 25, 57 hips), the mean navigation errors were 2.6 ± 2.4° for inclination and 2.4 ± 2.4° for anteversion. We found no significant difference between overweight and non-overweight patients in both inclination and anteversion. There was no correlation between the extent of errors and BMI. Conclusions: In posterolateral THA, CT-navi can aid the precise placement of the acetabular cup irrespective of a patient's BMI.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Surgery, Computer-Assisted , Body Mass Index , Humans , Retrospective Studies , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods
5.
J Orthop Sci ; 27(4): 792-797, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34039520

ABSTRACT

BACKGROUND: Fatty infiltration of the gluteus muscles increases due to the presence of hip osteoarthritis (OA); it is often evident in the gluteus minimus. The gluteus minimus acts not only as an abductor and rotator but also helps stabilize the femur's head. Moreover, the atrophy or fatty infiltration of the gluteus minimus leads to an increased risk of fall and fracture. Until now, fatty infiltration of this muscle has often been evaluated using magnetic resonance imaging using the Goutallier classification system, originally developed for the rotator cuff. However, the accessibility of magnetic resonance imaging remains problematic, and the reliability of the classification has room for improvement. Thus, this study aimed to devise a new classification system for the fatty infiltration of the gluteus minimus using plain computed tomography (CT). METHODS: We retrospectively reviewed 71 patients (141 hips) who underwent unilateral total hip arthroplasty for hip OA. To assess the system's reliability, three doctors classified the fatty infiltration of the gluteus minimus based on the CT images of 20 hips randomly selected from the study participants using both the Goutallier and the new classification systems. Then, we selected 113 hips with Crowe type 1 and evaluated them using the new classification system to assess the association between the extent of fatty infiltration and the severity of hip OA. RESULTS: Both classifications had good intra- and inter-observer reliability. The kappa values of the new classification system (0.83-0.95) were higher than that of the Goutallier classification system (0.72-0.87). The Jonckheere-Terpstra test showed that the degree of fatty infiltration of the gluteus minimus according to the new system progressed incrementally with the progression of hip OA (p = 0.016). CONCLUSIONS: The new classification system can be recommended for clinical use.


Subject(s)
Osteoarthritis, Hip , Buttocks/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/pathology , Osteoarthritis, Hip/diagnostic imaging , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
6.
Arch Orthop Trauma Surg ; 142(11): 3539-3547, 2022 Nov.
Article in English | MEDLINE | ID: mdl-34799746

ABSTRACT

INTRODUCTION: Total hip arthroplasty (THA) after rotational acetabular osteotomy (RAO) is technically demanding because of the characteristic acetabular morphology after RAO. The present study aimed to investigate the differences in the three-dimensional cup position between THA after RAO and primary THA. MATERIALS AND METHODS: We analysed the pre-operative and post-operative computed tomography (CT) data of 120 patients (20 patients after RAO and 100 patients without a history of RAO) who underwent THA between January 2017 and June 2018. We evaluated radiographic parameters, including acetabular anteversion, antero-posterior distance at the level of the femoral head centre, the presence of anterior acetabular osteophyte and/or rotated fragment during RAO from the CT data. Additionally, operative data and clinical scores were also evaluated. RESULTS: Although we found no significant differences in any clinical parameters, there were significant differences in radiographic parameters and operative data. The morphology of the acetabulum was significantly retroverted, and the antero-posterior distance was longer in patients after RAO, compared to the implanted cup. Additionally, longer operative time was necessary for such patients. These results reflect the atypical acetabular morphology after RAO, and emphasize that care should be taken to avoid anterior bony impingement and post-operative dislocation. CONCLUSION: For cup implantation during THA after RAO, surgeons should acknowledge the atypical morphology of the acetabulum and not be misled by its visual shape.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Femur Head/surgery , Humans , Osteotomy/methods , Retrospective Studies
7.
Knee ; 34: 98-107, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34875500

ABSTRACT

BACKGROUND: Component gap (CG) measurement help surgeons evaluate intraoperative soft-tissue balance. One technique is measuring the CG using tensioner devices with distraction force. Another is to evaluate the laxity under a varus-valgus force using navigation or robotics. The aim was to compare the JL evaluated by CG and varus-valgus force between the different types of total knee arthroplasties. METHODS: Forty-three bi-cruciate stabilized (BCS) knees and 33 bi-cruciate retaining (BCR) knees were included. After bone resection and soft tissue balancing, the CG was measured and after the final implantation and capsule closure, JL under a maximum varus-valgus stress was recorded with navigation. JL evaluated by the CG (JLCG) was defined as CG minus selected thickness of the tibial component and JL under varus-valgus force (JLVV) was defined as difference between varus-valgus angles without stress and maximum varus-valgus angles under varus-valgus force. The evaluations were performed at flexions of 10°, 30°, 60° and 90°. RESULTS: Although JLCGs of lateral compartment of BCS were larger than those of BCR, no difference was found between JLVVs of BCS and BCR. Although JLCGs of lateral compartment did not change at each knee flexion angle in both BCS and BCR, JLVVs of lateral compartment increased by 3° from 10° to 90° knee flexion. CONCLUSION: JLVVs of BCS and BCR were equivalent, whereas BCS showed larger JLCGs of lateral compartment. JLVVs of lateral compartment increased by 3° in the range from 10° to 90° knee flexion whereas JLCGs remained stable.


Subject(s)
Arthroplasty, Replacement, Knee , Joint Instability , Osteoarthritis, Knee , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Humans , Joint Instability/surgery , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Range of Motion, Articular
8.
Medicina (Kaunas) ; 57(11)2021 Nov 09.
Article in English | MEDLINE | ID: mdl-34833437

ABSTRACT

Background and objectives: The influence of changes in spinal alignment after total hip arthroplasty (THA) on improvement in lower back pain (LBP) remains controversial. To evaluate how changes in spinal malalignment correlate with improvement in preoperative LBP in patients who underwent THA for hip osteoarthritis. Materials and Methods: From November 2015 to January 2017, 104 consecutive patients who underwent unilateral THA were prospectively registered. Whole spine X-rays and patient-reported outcomes (PROs) were obtained preoperatively and 12 months postoperatively. The PROs used were the Numerical Rating Scale (NRS) for back pain, EuroQol 5 Dimension, and Short Form-12. Results: Seventy-four (71%) patients with complete data were eligible for the analysis. The sagittal parameters changed slightly but significantly. Coronal alignment significantly improved. Twenty-six (37%) patients had LBP preoperatively. These patients had smaller lumbar lordosis (LL), larger PT, and larger PI minus LL than the patients without LBP. Fourteen (54%) of the 26 patients with preoperative LBP showed pain improvement, but there were no significant differences in the radiographic parameters. Conclusions: Although preoperative LBP was likely to be resolved after THA, there were no significant correlations between alignment changes and LBP improvement. The cause of LBP in patients with hip osteoarthritis (OA) patients might be multifactorial.


Subject(s)
Arthroplasty, Replacement, Hip , Lordosis , Low Back Pain , Osteoarthritis, Hip , Humans , Low Back Pain/etiology , Low Back Pain/surgery , Osteoarthritis, Hip/complications , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/surgery , Spine
9.
Regen Med ; 16(6): 535-548, 2021 06.
Article in English | MEDLINE | ID: mdl-34075804

ABSTRACT

Aim: This study aimed to evaluate the 2-year outcomes from a clinical trial of recombinant human FGF-2 (rhFGF-2) for osteonecrosis of the femoral head (ONFH). Patients & methods: Sixty-four patients with nontraumatic, precollapse and large ONFHs were percutaneously administered with 800 µg rhFGF-2 contained in gelatin hydrogel. Setting the end point of radiological collapse, we analyzed the joint preservation period of the historical control. Changes in two validated clinical scores, bone regeneration and safety were evaluated. Results: Radiological joint preservation time was significantly higher in the rhFGF-2 group than in the control group. The ONFHs tended to improve to smaller ONFHs. The postoperative clinical scores significantly improved. Thirteen serious adverse events showed recovery. Conclusion: rhFGF-2 treatment increases joint preservation time with clinical efficacy, radiological bone regeneration and safety.


Lay abstract Osteonecrosis of the femoral head is a disease that causes pain in the hip joint, making it impossible to walk. The causes of the disease are the use of corticosteroids and the drinking of alcohol. As the disease progresses, the hip joint needs to be replaced with an artificial joint. Risks with hip replacement surgery can include infection, implant dislocation, implant fracture and implant wear. The goal of this trial was to treat the disease with simple surgery using a drug called FGF. The surgical wound was 1 cm and the surgery took only 5 min. The results in 64 patients were better than in those without treatment. FGF treatment can be a therapeutic option for osteonecrosis of the femoral head.


Subject(s)
Arthroplasty, Replacement, Hip , Femur Head Necrosis , Femur Head/diagnostic imaging , Femur Head Necrosis/diagnostic imaging , Femur Head Necrosis/drug therapy , Fibroblast Growth Factor 2 , Humans , Treatment Outcome
10.
J Int Med Res ; 49(6): 3000605211023336, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34187212

ABSTRACT

OBJECTIVE: In this study, we aimed to elucidate the relationship between the duration from diagnosis to femoral head collapse and the collapse rate among patients with pre-collapse osteonecrosis of the femoral head (ONFH). METHODS: In this retrospective, observational, multicenter study, we analyzed 268 patients diagnosed with ONFH and classified them using the Japanese Investigation Committee classification. The primary endpoint was duration from the time of diagnosis to femoral head collapse for each type of ONFH. RESULTS: The 12-, 24-, and 36-month collapse rates among participants were 0%, 0%, and 0% for type A, respectively; 0%, 2.0%, and 10.8% for type B, respectively; 25.5%, 40.8%, and 48.5% for type C-1, respectively; and 57.4%, 70.3%, and 76.7% for type C-2 ONFH, respectively. A comparison of unilateral and bilateral ONFH, using Kaplan-Meier survival curves demonstrated similar collapse rates. CONCLUSIONS: The lowest collapse rate was observed for ONFH type A, followed by types B, C-1, and C-2. Additionally, a direct association was observed between the collapse rate and location of the osteonecrotic lesion on the weight-bearing surface.


Subject(s)
Femur Head Necrosis , Femur Head , Humans , Japan , Kaplan-Meier Estimate , Retrospective Studies
11.
World J Orthop ; 12(4): 207-213, 2021 Apr 18.
Article in English | MEDLINE | ID: mdl-33959484

ABSTRACT

Fracture of an ossification of the Achilles tendon (OAT) is a rare entity, and its etiology, pathology, and treatment remain unclear. We reviewed and scrutinized 18 cases (16 articles) of the fracture of an OAT. The most common etiologies of the ossifications include previous surgery and trauma. The fractures often occur without any trigger or with minimal trigger. The long, > 5 cm, ossification in the body of the Achilles tendon may have a higher risk of fracture. The OAT itself is often asymptomatic; however, its fracture causes severe local pain, swelling, and weakness of plantar flexion, which forces patients to undergo aggressive treatments. Regarding the treatments of the fractures, nonoperative treatment by immobilizing ankle joint could be an option for elderly patients. However, because it often cannot produce satisfactory results in younger patients, surgical treatment is typically recommended. Excision of the fractured mass and repairing the tendon is applicable if the remnant is enough. If there is a defect after the excision, reconstruction with autologous grafts or adjacent tendon transfer is performed. Gastrocnemius fascia turndown flap, hamstring tendon and tensor fascia lata are used as autologous grafts, whereas peroneus brevis and flexor hallucis longus tendons are used for the tendon transfer. If the fracture of an OAT is treated properly, the functional result will be satisfactory.

12.
BMC Musculoskelet Disord ; 22(1): 482, 2021 May 25.
Article in English | MEDLINE | ID: mdl-34034743

ABSTRACT

BACKGROUND: Hip arthroplasty using acrylic prosthesis was once conducted; however, it has now been abandoned because of early breakages and wear of material. Therefore, complications or revision surgeries due to the use of acrylic prostheses are becoming rare. CASE PRESENTATION: A 76-year-old woman presented with a sudden onset of severe pain in her left femur while walking. Radiographs revealed severe osteolysis and periprosthetic femoral fracture 45 years after the initial hemiarthroplasty using an acrylic prosthesis. We performed a Girdlestone resection arthroplasty by removing the prosthesis and fixing the fracture site using an intramedullary nail and metal plate. The patient was pain-free in her hip and leg 2 years and 9 months after the surgery. Although she walked with a cane or crutches, no postoperative complications were observed. CONCLUSIONS: The combined use of an intramedullary nail and plate fixation with resection arthroplasty could offer acceptable results for patients with severe osteolysis and periprosthetic fracture after femoral head replacement using an acrylic prosthesis. Our report seems relevant because it not only reminds us of the significant steps made in the development of modern total hip arthroplasty; it also highlights one of the surgical options for severe osteolysis and periprosthetic fracture of the hip.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hemiarthroplasty , Hip Prosthesis , Osteolysis , Periprosthetic Fractures , Aged , Arthroplasty, Replacement, Hip/adverse effects , Female , Femoral Fractures/surgery , Femur/surgery , Hemiarthroplasty/adverse effects , Hip Prosthesis/adverse effects , Humans , Osteolysis/diagnostic imaging , Osteolysis/etiology , Osteolysis/surgery , Periprosthetic Fractures/diagnostic imaging , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgery , Reoperation
13.
J Orthop Surg Res ; 16(1): 192, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-33722270

ABSTRACT

BACKGROUND: Rotational acetabular osteotomy (RAO) is a type of pelvic osteotomy performed to improve the acetabular bony coverage against the femoral head for patients with acetabular dysplasia. The acetabular bony coverage is ideally evaluated three-dimensionally; however, there is a paucity of published data regarding three-dimensional morphology in patients with long-term excellent outcome after RAO. The present study investigated the characteristics of three-dimensional acetabular morphology with long-term excellent outcome after RAO in comparison to patients with normal hip joints and those converted to total hip arthroplasty (THA) after RAO because of osteoarthritis (OA) progression. METHODS: Anteroposterior plain radiograph and computed tomography data of 57 hip joints (17 joints with excellent outcome 20 years or more after RAO, 16 normal joints, and 20 joints converted to THA after RAO) were analyzed. The two-dimensional lateral center-edge (CE) angle from plain radiographs and acetabular anteversion, anterior acetabular sector angle, and posterior sector angle from computed tomography (CT) images were calculated. RESULTS: Compared with patients converted to THA, all parameters in patients with long-term excellent outcome after RAO were similar to those in patients with normal hip joints, particularly in the three-dimensional analyses. The anterior bony coverage was excessive, whereas the posterior bony coverage was deficient in patients converted to THA after RAO. Anterior bony impingement and posterior instability may be the cause of OA progression after RAO. CONCLUSION: Caution must be taken to avoid rotating the separated fragment excessively to the anterior direction during RAO to prevent OA progression and achieve long-term excellent outcome.


Subject(s)
Acetabulum/diagnostic imaging , Acetabulum/surgery , Bone Diseases, Developmental/diagnostic imaging , Bone Diseases, Developmental/surgery , Imaging, Three-Dimensional , Osteoarthritis/diagnostic imaging , Osteoarthritis/surgery , Osteotomy/methods , Adolescent , Adult , Aged , Arthroplasty, Replacement, Hip , Child , Disease Progression , Female , Humans , Male , Middle Aged , Radiography , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
14.
J Orthop Surg (Hong Kong) ; 28(3): 2309499020954315, 2020.
Article in English | MEDLINE | ID: mdl-32996412

ABSTRACT

PURPOSE: The results of reamed bipolar hemiarthroplasty (BHA) in patients with hip osteoarthritis (OA) are reported to be unfavorable. Acetabular reaming for sufficient bony coverage caused bipolar head migration into the superomedial direction, and most patients required revision surgeries. Several methods are applicable to treat decreased bone stock. This study aimed to investigate the midterm results of revision surgeries using the cementless cup with the rim-fit technique. METHODS: Between 1996 and 2014, acetabular revision surgeries using the cementless cup with the rim-fit technique were performed in 86 hips (74 patients). We evaluated radiographic outcomes, including positional change of the rotation center of the artificial femoral head, presence of implant loosening, and filling of the initial gap. We also evaluated clinical outcomes, including the Harris hip score (HHS), and postoperative complications. RESULTS: The average positional changes from BHA to prerevision surgeries were 8.0 mm superiorly and 4.1 mm medially. The average changes from prerevision to postrevision surgeries were 3.7 mm inferiorly and 2.4 mm laterally. No implant loosening was found in all cases; the initial gap between the acetabular host bone and the acetabular cup was filled in 53 (93%) among 57 hips. The average HHS improved from 65.9 before revision surgeries to 83.8 in the latest follow-up. Dislocation and postoperative periprosthetic fracture occurred in two and five hips, respectively; no cases required rerevision surgeries. CONCLUSION: There were favorable midterm results of the revision total hip arthroplasty for migrated BHA in patients with hip OA using cementless cup with the rim-fit technique.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Femur Head/surgery , Hemiarthroplasty/methods , Hip Prosthesis , Osteoarthritis, Hip/surgery , Periprosthetic Fractures/surgery , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies , Time Factors
15.
Artif Organs ; 43(6): 569-576, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30412266

ABSTRACT

Optimization of the combined anteversion of cup and stem has been emphasized to avoid prosthetic impingement in total hip arthroplasty (THA). However, no study has focused on the impact of variations in sagittal and coronal stem tilt against the whole femur on prosthetic range of motion. The purposes of the present study were a) to quantify the anatomical variation of sagittal and coronal tilt of the proximal canal axis against the femoral retrocondylar coordinate system, that is variation of sagittal and coronal stem tilt and b) to determine their impact on the zone of impingement-free cup position using computer simulation. Preoperative computed tomography images of 477 femurs from 409 consecutive patients who underwent THA using computed tomography-based computer navigation were stored. Virtual implantation of an anatomical stem was performed on the navigation workstation. The safe zone of the cup position with regard to prosthetic impingement was determined by motion simulation in the range of sagittal and coronal stem tilt of the subjects. The sagittal and coronal stem tilt varied by 10°, which was smaller than the stem anteversion variation. However, there was about 3 times the difference in the impingement-free zone of cup position in the ranges of sagittal and coronal stem tilt. The safe zone was significantly decreased by posterior tilt and valgus tilt of the stem. Range of motion simulation revealed that the variations in sagittal or coronal stem tilt significantly influenced the safe zone of the cup. In conclusion, although the variations in sagittal and coronal stem tilt against the femoral retrocondylar coordinate system were small, their impact on prosthetic impingement was significant.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Adult , Aged , Aged, 80 and over , Female , Femur/diagnostic imaging , Femur/surgery , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis , Humans , Male , Middle Aged , Range of Motion, Articular , Young Adult
16.
Acta Biomater ; 86: 338-349, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30590185

ABSTRACT

Although laboratory tests and mid-term clinical outcomes show the clinical safety and remarkable wear resistance of the highly cross-linked polyethylene (HXLPE) acetabular liner with a nanometer-scaled graft layer of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC), the wear resistance of the layer under severe abrasive conditions is concerning. We evaluated the effects of a roughened femoral head and the grafting locus on the wear resistance of the PMPC-grafted HXLPE liner and the effect of PMPC grafting on wear resistance of the HXLPE substrate by removing the PMPC-grafted layer using a severely roughened femoral head. Against a moderately roughened femoral head, the PMPC-grafted HXLPE liner showed negative wear, although an untreated HXLPE liner increased the wear by 154.1% compared with wear against a polished femoral head, confirming that PMPC grafts were unaffected. Against a severely roughened femoral head, the PMPC-grafted layer of the head contact area might be removed under severe conditions. However, the wear rate was reduced by 52.5% compared to that of untreated HXLPE liners. Moreover, the head non-contact area-modified PMPC-grafted HXLPE liner against a polished femoral head reduced the wear by 76.8% compared with untreated HXLPE liner; thus, this area may be also important in the development of fluid-film lubrication. STATEMENT OF SIGNIFICANCE: Here we describe effects of a roughened femoral head and the locus of grafting on the wear-resistance of the phospholipid polymer grafted highly cross-linked polyethylene (PMPC-HXLPE) liner. Against a moderately roughened femoral head, the PMPC-HXLPE liner showed negative wear, confirming that PMPC grafts were unaffected. After removing the PMPC layer of the head contact area using a severely roughened femoral head, the wear rate not only exceeded that of untreated HXLPE liners, but was reduced by 52.5%, confirming that PMPC grafting does not affect the wear-resistance of the HXLPE substrate. In addition, the head non-contact area-modified PMPC-HXLPE liner reduced the wear by 76.8%. Thus, this area may also may be important in the development of fluid-film lubrication.


Subject(s)
Acetabulum/physiology , Femur Head/transplantation , Methacrylates/chemistry , Phosphorylcholine/analogs & derivatives , Polymers/chemistry , Cross-Linking Reagents/chemistry , Humans , Phosphorylcholine/chemistry , Polyethylene/chemistry
17.
Case Rep Orthop ; 2018: 8384079, 2018.
Article in English | MEDLINE | ID: mdl-29610693

ABSTRACT

We present the case of a 28-year-old woman with oto-spondylo-megaepiphyseal dysplasia, which is a rare skeletal disorder, who underwent bilateral total hip arthroplasty. Full-scale three-dimensional plaster model of the acetabulum and the femur provided us with a feasible preoperative plan. Pre- and postoperative three-dimensional motion analyses proved a significant improvement in her ambulation and confirmed the efficacy of total hip arthroplasty. In conclusion, full-scale three-dimensional plaster models of the bone and three-dimensional motion analyses were useful for total hip arthroplasty in patients with skeletal dysplasia.

18.
Int Orthop ; 42(11): 2527-2534, 2018 11.
Article in English | MEDLINE | ID: mdl-29484472

ABSTRACT

PURPOSE: Rotational acetabular osteotomy is a type of pelvic osteotomy that involves rotation of the acetabular bone to improve the bony coverage of the femoral head for patients with acetabular dysplasia. Favourable post-operative long-term outcomes have been reported in previous studies. However, there is a paucity of published data regarding three-dimensional bony coverage. The present study investigated the three-dimensional bony coverage of the acetabulum covering the femoral head in hips before and after rotational acetabular osteotomy and in normal hips. METHODS: The computed tomography data of 40 hip joints (12 joints before and after rotational acetabular osteotomy; 16 normal joints) were analyzed. The three-dimensional bony coverage of each joint was evaluated using original software. RESULTS: The post-operative bony coverage improved significantly compared with pre-operative values. In particular, the anterolateral aspect of the acetabulum tended to be dysplastic in patients with acetabular dysplasia compared to those with normal hip joints. However, greater bony coverage at the anterolateral aspect was obtained after rotational acetabular osteotomy. Meanwhile, the results of the present study may indicate that the bony coverage in the anterior aspect may be excessive. CONCLUSION: Three-dimensional analysis indicated that rotational acetabular osteotomy achieved favorable bony coverage. Further investigations are necessary to determine the ideal bony coverage after rotational acetabular osteotomy.


Subject(s)
Acetabulum/surgery , Hip Dislocation, Congenital/surgery , Imaging, Three-Dimensional/methods , Osteotomy/methods , Tomography, X-Ray Computed/methods , Acetabulum/diagnostic imaging , Adolescent , Adult , Aged , Female , Hip Dislocation, Congenital/diagnostic imaging , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Middle Aged , Young Adult
19.
J Arthroplasty ; 32(10): 3065-3070, 2017 10.
Article in English | MEDLINE | ID: mdl-28579445

ABSTRACT

BACKGROUND: We evaluated the clinical and radiographic outcomes, including femoral head penetration, of total hip arthroplasty performed using a specific polyethylene (PE) liner in small Asian patients at 10 years after the index surgery. In addition, we investigated whether femoral head penetration was affected by patient-related, implant-related, and surgical factors. METHODS: Between August 2002 and June 2005, for cementless primary total hip arthroplasty, we used acetabular PE liners that were manufactured from GUR 1050 resin, machined from isostatic compression-molded bar stock, and sterilized with a gamma ray irradiation in argon gas. We assessed 82 hips in 78 patients who received these liners. RESULTS: The mean Harris hip score improved from 41.0 preoperatively to 84.5 at 10 years postoperatively. Periprosthetic osteolysis was observed in 7 hips (9.8%). No acetabular component migration was detected, and no revision surgery was performed 10 years postoperatively. The mean steady-state wear rate was 0.031 mm/y, which was lower than the wear rate for other conventional PE liners of the previous studies. Among the patient-related, implant-related, and surgical factors, sex was significantly associated with the mean steady-state wear rate, with a higher rate in male patients than in female patients. CONCLUSION: PE acetabular liners used in small Asian patients show similar clinical outcomes and reduced wear compared with those of other liners. In addition, sex is significantly associated with the mean steady-state wear rate, and the steady-state wear rate is higher in male patients than in female patients.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Adult , Aged , Arthroplasty, Replacement, Hip/statistics & numerical data , Asian People , Female , Femur Head/diagnostic imaging , Femur Head/surgery , Humans , Male , Middle Aged , Osteolysis , Polyethylene , Prosthesis Design , Prosthesis Failure , Radiography , Reoperation , Young Adult
20.
Orthopedics ; 40(2): e374-e377, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-27841929

ABSTRACT

To ensure that the femoral stem is placed in the proper position during total hip arthroplasty, the authors developed a patient-specific instrument. A total of 10 total hip arthroplasties were performed with the assistance of the patient-specific instrument during this study. The mean accuracy of stem tilt, varus/valgus, and anteversion was 2.1°±4.1°, 1.0°±0.7°, and 4.7°±1.2°, respectively. No complications were observed and no reoperations were required for any of the patients who underwent surgery included in this study. The results support the feasibility of this patient-specific instrument for use during stem placement in total hip arthroplasty. [Orthopedics. 2017; 40(2):e374-e377.].


Subject(s)
Arthroplasty, Replacement, Hip/methods , Computer-Aided Design , Hip Prosthesis , Preoperative Care/methods , Prosthesis Design , Surgery, Computer-Assisted/methods , Aged , Arthroplasty, Replacement, Hip/instrumentation , Feasibility Studies , Female , Femur/surgery , Humans , Imaging, Three-Dimensional , Middle Aged , Multidetector Computed Tomography , Surgery, Computer-Assisted/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...