Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Insights Imaging ; 15(1): 115, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735018

ABSTRACT

OBJECTIVES: The simplified endoscopic score of Crohn's disease (SES-CD) is the gold standard for quantitatively evaluating Crohn's disease (CD) activity but is invasive. This study aimed to develop and validate a machine learning (ML) model based on dual-energy CT enterography (DECTE) to noninvasively evaluate CD activity. METHODS: We evaluated the activity in 202 bowel segments of 46 CD patients according to the SES-CD score and divided the segments randomly into training set and testing set at a ratio of 7:3. Least absolute shrinkage and selection operator (LASSO) was used for feature selection, and three models based on significant parameters were established based on logistic regression. Model performance was evaluated using receiver operating characteristic (ROC), calibration, and clinical decision curves. RESULTS: There were 110 active and 92 inactive bowel segments. In univariate analysis, the slope of spectral curve in the venous phases (λHU-V) has the best diagnostic performance, with an area under the ROC curve (AUC) of 0.81 and an optimal threshold of 1.975. In the testing set, the AUC of the three models established by the 7 variables to differentiate CD activity was 0.81-0.87 (DeLong test p value was 0.071-0.766, p > 0.05), and the combined model had the highest AUC of 0.87 (95% confidence interval (CI): 0.779-0.959). CONCLUSIONS: The ML model based the DECTE can feasibly evaluate CD activity, and DECTE parameters provide a quantitative analysis basis for evaluating specific bowel activities in CD patients. CRITICAL RELEVANCE STATEMENT: The machine learning model based on dual-energy computed tomography enterography can be used for evaluating Crohn's disease activity noninvasively and quantitatively. KEY POINTS: Dual-energy CT parameters are related to Crohn's disease activity. Three machine learning models effectively evaluated Crohn's disease activity. Combined models based on conventional and dual-energy CT have the best performance.

2.
Front Nutr ; 10: 1251448, 2023.
Article in English | MEDLINE | ID: mdl-37674885

ABSTRACT

Background: The disease activity status and behavior of Crohn's disease (CD) can reflect the severity of the disease, and changes in body composition are common in CD patients. Aims: The aim of this study was to investigate the relationship between body composition parameters and disease severity in CD patients treated with infliximab (IFX). Methods: Patients with CD assessed with the simple endoscopic score (SES-CD) and were treated with IFX were retrospectively collected, and body composition parameters at the level of the 3rd lumbar vertebrae were calculated from computed tomography (CT) scans of the patients. The correlation of patients' body composition parameters with disease activity status and disease behavior was analyzed, and the diagnostic value of the relevant parameters was assessed using receiver operating characteristic (ROC) curves. Results: A total of 106 patients were included in this study. There were significant differences in the subcutaneous adiposity index (SAI) (p = 0.010), the visceral adiposity index (VAI) (p < 0.001), the skeletal muscle mass index (SMI) (p < 0.001), and decreased skeletal muscle mass (p < 0.001) among patients with different activity status. After Spearman and multivariate regression analysis, SAI (p = 0.006 and p = 0.001), VAI (p < 0.001 and p < 0.001), and SMI (p < 0.001and p = 0.007) were identified as independent correlates of disease activity status (both disease activity and moderate-to-severe activity), with disease activity status independently positively correlated with SAI and SMI and independently negatively correlated with VAI. In determining the disease activity and moderate-to-severe activity status, SMI performed best relative to SAI and VAI, with areas under the ROC curve of 0.865 and 0.801, respectively. SAI (p = 0.015), SMI (p = 0.011) and decreased skeletal muscle mass (p = 0.027) were significantly different between different disease behavior groups (inflammatory disease behavior group, complex disease behavior group) but were not independent correlates (p > 0.05). Conclusion: Body composition parameters of CD patients treated with IFX correlate with the endoscopic disease severity, and SMI can be used as a reliable indicator of disease activity status.

3.
Int J Colorectal Dis ; 38(1): 126, 2023 May 12.
Article in English | MEDLINE | ID: mdl-37171498

ABSTRACT

BACKGROUND AND AIMS: Body composition changes in patients with Crohn's disease (CD) have received increasing attention in recent years. This review aims to describe the changes in body composition in patients with CD on imaging and to analyze and summarize the prognostic value of body composition. METHODS: We systematically searched Web of Science, PubMed, Embase, Cochrane Library, and Medline via OVID for literature published before November 2022, and two researchers independently evaluated the quality of the retrieved literature. RESULTS: A total of 39 publications (32 cohort studies and 7 cross-sectional studies) involving 4219 patients with CD were retrieved. Imaging methods for body composition assessment, including dual-energy X-ray absorptiometry (DXA), computed tomography (CT) and magnetic resonance imaging (MRI), were included in this review. The study found that patients with CD typically have more visceral adipose tissue and less skeletal muscle mass, and the prevalence of sarcopenia and visceral obesity was significantly different in different studies (sarcopenia: 16-100%; visceral obesity: 5.3-30.5%). Available studies suggest that changes in the body composition of CD patients are significantly related to inflammatory status, disease behavior, poor outcomes, and drug efficacy. CONCLUSION: Altered body composition can be a significant predictor of poor outcomes for CD patients. Therefore, the body composition of CD patients may serve as a potential therapeutic target to help optimize disease management strategies in clinical practice.


Subject(s)
Crohn Disease , Sarcopenia , Humans , Crohn Disease/complications , Crohn Disease/diagnostic imaging , Obesity, Abdominal , Cross-Sectional Studies , Body Composition
4.
Front Neurosci ; 16: 1002717, 2022.
Article in English | MEDLINE | ID: mdl-36213752

ABSTRACT

Objective: To develop and validate a model based on the radiomics features of the infarct areas on non-contrast-enhanced CT to predict hemorrhagic transformation (HT) in acute ischemic stroke. Materials and methods: A total of 118 patients diagnosed with acute ischemic stroke in two centers from January 2019 to February 2022 were included. The radiomics features of infarcted areas on non-contrast-enhanced CT were extracted using 3D-Slicer. A univariate analysis and the least absolute shrinkage and selection operator (LASSO) were used to select features, and the radiomics score (Rad-score) was then constructed. The predictive model of HT was constructed by analyzing the Rad-score and clinical and imaging features in the training cohort, and it was verified in the validation cohort. The model was evaluated with the receiver operating characteristic curve, calibration curve and decision curve, and the prediction performance of the model in different scenarios was further discussed hierarchically. Results: Of the 118 patients, 52 developed HT, including 21 cases of hemorrhagic infarct (HI) and 31 cases of parenchymal hematoma (PH). The Rad-score was constructed from five radiomics features and was the only independent predictor for HT. The predictive model was constructed from the Rad-score. The area under the curve (AUCs) of the model for predicting HT in the training and validation cohorts were 0.845 and 0.750, respectively. Calibration curve and decision curve analyses showed that the model performed well. Further analysis found that the model predicted HT for different infarct sizes or treatment methods in the training and validation cohorts with 78.3 and 71.4% accuracy, respectively. For all samples, the model predicted an AUC of 0.754 for HT in patients within 4.5 h since stroke onset, and predicted an AUC of 0.648 for PH. Conclusion: This model, which was based on CT radiomics features, could help to predict HT in the setting of acute ischemic stroke for any infarct size and provide guiding suggestions for clinical treatment and prognosis evaluation.

SELECTION OF CITATIONS
SEARCH DETAIL
...