Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Article in English | MEDLINE | ID: mdl-38824470

ABSTRACT

PURPOSE: Currently, the intra-operative visualization of vessels during endovascular aneurysm repair (EVAR) relies on contrast-based imaging modalities. Moreover, traditional image fusion techniques lack a continuous and automatic update of the vessel configuration, which changes due to the insertion of stiff guidewires. The purpose of this work is to develop and evaluate a novel approach to improve image fusion, that takes into account the deformations, combining electromagnetic (EM) tracking technology and finite element modeling (FEM). METHODS: To assess whether EM tracking can improve the prediction of the numerical simulations, a patient-specific model of abdominal aorta was segmented and manufactured. A database of simulations with different insertion angles was created. Then, an ad hoc sensorized tool with three embedded EM sensors was designed, enabling tracking of the sensors' positions during the insertion phase. Finally, the corresponding cone beam computed tomography (CBCT) images were acquired and processed to obtain the ground truth aortic deformations of the manufactured model. RESULTS: Among the simulations in the database, the one minimizing the in silico versus in vitro discrepancy in terms of sensors' positions gave the most accurate aortic displacement results. CONCLUSIONS: The proposed approach suggests that the EM tracking technology could be used not only to follow the tool, but also to minimize the error in the predicted aortic roadmap, thus paving the way for a safer EVAR navigation.

2.
Front Physiol ; 14: 1098867, 2023.
Article in English | MEDLINE | ID: mdl-37492644

ABSTRACT

Introduction and aims: During an Endovascular Aneurysm Repair (EVAR) procedure a stiff guidewire is inserted from the iliac arteries. This induces significant deformations on the vasculature, thus, affecting the pre-operative planning, and the accuracy of image fusion. The aim of the present work is to predict the guidewire induced deformations using a finite element approach validated through experiments with patient-specific additive manufactured models. The numerical approach herein developed could improve the pre-operative planning and the intra-operative navigation. Material and methods: The physical models used for the experiments in the hybrid operating room, were manufactured from the segmentations of pre-operative Computed Tomography (CT) angiographies. The finite element analyses (FEA) were performed with LS-DYNA Explicit. The material properties used in finite element analyses were obtained by uniaxial tensile tests. The experimental deformed configurations of the aorta were compared to those obtained from FEA. Three models, obtained from Computed Tomography acquisitions, were investigated in the present work: A) without intraluminal thrombus (ILT), B) with ILT, C) with ILT and calcifications. Results and discussion: A good agreement was found between the experimental and the computational studies. The average error between the final in vitro vs. in silico aortic configurations, i.e., when the guidewire is fully inserted, are equal to 1.17, 1.22 and 1.40 mm, respectively, for Models A, B and C. The increasing trend in values of deformations from Model A to Model C was noticed both experimentally and numerically. The presented validated computational approach in combination with a tracking technology of the endovascular devices may be used to obtain the intra-operative configuration of the vessels and devices prior to the procedure, thus limiting the radiation exposure and the contrast agent dose.

3.
Neurosurgery ; 66(1): 173-85; discussion 185-6, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20023548

ABSTRACT

OBJECTIVE: Residual tumor masses are common after transsphenoidal surgery. The risk of a residual mass increases with tumor size and parasellar or suprasellar growth. Transsphenoidal surgery is usually performed without image guidance. We aimed to investigate a new technical solution developed for intraoperative ultrasound imaging during transsphenoidal surgery, with respect to potential clinical use and the ability to identify neuroanatomy and tumor. METHODS: In 9 patients with pituitary macroadenomas, intrasphenoidal and intrasellar ultrasound was assessed during transsphenoidal operations. Ultrasound B-mode, power-Doppler and color-Doppler images were acquired using a small prototype linear array, side-looking probe. The long probe tip measures only 3 x 4 mm. We present images and discuss the potential of intrasphenoidal and intrasellar and ultrasound in transsphenoidal surgery. RESULTS: We present 2-dimensional, high-resolution ultrasound images. A small side-looking, high-frequency ultrasound probe can be used to ensure orientation in the midline for the surgical approach to identify important neurovascular structures to be avoided during surgery and for resection control and identification of normal pituitary tissue. The image resolution is far better than what can be achieved with current clinical magnetic resonance imaging technology. CONCLUSION: We believe that the concept of intrasellar ultrasound can be further developed to become a flexible and useful tool in transsphenoidal surgery.


Subject(s)
Adenoma/surgery , Neurosurgical Procedures/methods , Pituitary Neoplasms/surgery , Sella Turcica/surgery , Sphenoid Sinus/surgery , Adenoma/diagnostic imaging , Adenoma/pathology , Adult , Aged , Echocardiography, Doppler/methods , Female , Follow-Up Studies , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Pituitary Neoplasms/diagnostic imaging , Pituitary Neoplasms/pathology , Sella Turcica/diagnostic imaging , Sella Turcica/pathology , Sphenoid Sinus/pathology
4.
Neurosurgery ; 65(6 Suppl): 149-57; discussion 157, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19934989

ABSTRACT

OBJECTIVE: The objective of this study was to investigate the clinical applicability of navigated blood flow imaging (BFI) in neurovascular applications. BFI is a new 2-dimensional ultrasound modality that offers angle-independent visualization of flow. When integrated with 3-dimensional (3D) navigation technology, BFI can be considered as a first step toward the ideal tool for surgical needs: a real-time, high-resolution, 3D visualization that properly portrays both vessel geometry and flow direction. METHODS: A 3D model of the vascular tree was extracted from preoperative magnetic resonance angiographic data and used as a reference for intraoperative any-plane guided ultrasound acquisitions. A high-end ultrasound scanner was interconnected, and synchronized recordings of BFI and 3D navigation scenes were acquired. The potential of BFI as an intraoperative tool for flow visualization was evaluated in 3 cerebral aneurysms and 3 arteriovenous malformations. RESULTS: The neurovascular flow direction was properly visualized in all cases using BFI. Navigation technology allowed for identification of the vessels of interest, despite the presence of brain shift. The surgeon found BFI to be very intuitive compared with conventional color Doppler methods. BFI allowed for quality control of sufficient flow in all distal arteries during aneurysm surgery and made it easier to discern between feeding arteries and draining veins during surgery for arteriovenous malformations. CONCLUSION: BFI seems to be a promising modality for neurovascular flow visualization that may provide the neurosurgeon with a valuable tool for safer surgical interventions. However, further work is needed to establish the clinical usefulness of the proposed imaging setup.


Subject(s)
Cerebral Arteries/diagnostic imaging , Cerebral Arteries/surgery , Cerebrovascular Circulation/physiology , Monitoring, Intraoperative/methods , Neurosurgical Procedures/methods , Ultrasonography/methods , Cerebral Arteries/physiology , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/surgery , Intracranial Arteriovenous Malformations/diagnostic imaging , Intracranial Arteriovenous Malformations/physiopathology , Intracranial Arteriovenous Malformations/surgery , Magnetic Resonance Angiography , Vascular Surgical Procedures/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...