1.
Biomicrofluidics ; 9(4): 044103, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26221198

ABSTRACT

Nanoscale synthetic biology can benefit from programmable nanoliter-scale processing of DNA in microfluidic chips if they are interfaced effectively to biochemical arrays such as microwell plates. Whereas active microvalve chips require complex fabrication and operation, we show here how a passive and readily fabricated microchip can be employed for customizable nanoliter scale pipetting and reaction control involving DNA. This recently developed passive microfluidic device, supporting nanoliter scale combinatorial droplet generation and mixing, is here used to generate a DNA test library with one member per droplet exported to addressed locations on microwell plates. Standard DNA assembly techniques, such as Gibson assembly, compatible with isothermal on-chip operation, are employed and checked using off-chip PCR and assembly PCR. The control of output droplet sequences and mixing performance was verified using dyes and fluorescently labeled DNA solutions, both on-chip and in external capillary channels. Gel electrophoresis of products and DNA sequencing were employed to further verify controlled combination and functional enzymatic assembly. The scalability of the results to larger DNA libraries is also addressed by combinatorial input expansion using sequential injection plugs from a multiwell plate. Hence, the paper establishes a proof of principle of the production of functional combinatorial mixtures at the nanoliter scale for one sequence per well DNA libraries.

2.
Electrophoresis ; 36(19): 2451-64, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26095642

ABSTRACT

Reversible noncovalent but sequence-dependent attachment of DNA to gels is shown to allow programmable mobility processing of DNA populations. The covalent attachment of DNA oligomers to polyacrylamide gels using acrydite-modified oligonucleotides has enabled sequence-specific mobility assays for DNA in gel electrophoresis: sequences binding to the immobilized DNA are delayed in their migration. Such a system has been used for example to construct complex DNA filters facilitating DNA computations. However, these gels are formed irreversibly and the choice of immobilized sequences is made once off during fabrication. In this work, we demonstrate the reversible self-assembly of gels combined with amphiphilic DNA molecules, which exhibit hydrophobic hydrocarbon chains attached to the nucleobase. This amphiphilic DNA, which we term lipid-DNA, is synthesized in advance and is blended into a block copolymer gel to induce sequence-dependent DNA retention during electrophoresis. Furthermore, we demonstrate and characterize the programmable mobility shift of matching DNA in such reversible gels both in thin films and microchannels using microelectrode arrays. Such sequence selective separation may be employed to select nucleic acid sequences of similar length from a mixture via local electronics, a basic functionality that can be employed in novel electronic chemical cell designs and other DNA information-processing systems.


Subject(s)
DNA/chemistry , Electrophoresis, Capillary/methods , Lipids/chemistry , Microfluidic Analytical Techniques/methods , Base Sequence , Microelectrodes
3.
Biomicrofluidics ; 9(1): 014119, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25759752

ABSTRACT

We here present and characterize a programmable nanoliter scale droplet-on-demand device that can be used separately or readily integrated into low cost single layer rapid prototyping microfluidic systems for a wide range of user applications. The passive microfluidic device allows external (off-the-shelf) electronically controlled pinch valves to program the delivery of nanoliter scale aqueous droplets from up to 9 different inputs to a central outlet channel. The inputs can be either continuous aqueous fluid streams or microliter scale aqueous plugs embedded in a carrier fluid, in which case the number of effective input solutions that can be employed in an experiment is no longer strongly constrained (100 s-1000 s). Both nanoliter droplet sequencing output and nanoliter-scale droplet mixing are reported with this device. Optimization of the geometry and pressure relationships in the device was achieved in several hardware iterations with the support of open source microfluidic simulation software and equivalent circuit models. The requisite modular control of pressure relationships within the device is accomplished using hydrodynamic barriers and matched resistance channels with three different channel heights, custom parallel reversible microfluidic I/O connections, low dead-volume pinch valves, and a simply adjustable array of external screw valves. Programmable sequences of droplet mixes or chains of droplets can be achieved with the device at low Hz frequencies, limited by device elasticity, and could be further enhanced by valve integration. The chip has already found use in the characterization of droplet bunching during export and the synthesis of a DNA library.

4.
Biosystems ; 109(1): 2-17, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22309763

ABSTRACT

The topic addressed is that of combining self-constructing chemical systems with electronic computation to form unconventional embedded computation systems performing complex nano-scale chemical tasks autonomously. The hybrid route to complex programmable chemistry, and ultimately to artificial cells based on novel chemistry, requires a solution of the two-way massively parallel coupling problem between digital electronics and chemical systems. We present a chemical microprocessor technology and show how it can provide a generic programmable platform for complex molecular processing tasks in Field Programmable Chemistry, including steps towards the grand challenge of constructing the first electronic chemical cells. Field programmable chemistry employs a massively parallel field of electrodes, under the control of latched voltages, which are used to modulate chemical activity. We implement such a field programmable chemistry which links to chemistry in rather generic, two-phase microfluidic channel networks that are separated into weakly coupled domains. Electric fields, produced by the high-density array of electrodes embedded in the channel floors, are used to control the transport of chemicals across the hydrodynamic barriers separating domains. In the absence of electric fields, separate microfluidic domains are essentially independent with only slow diffusional interchange of chemicals. Electronic chemical cells, based on chemical microprocessors, exploit a spatially resolved sandwich structure in which the electronic and chemical systems are locally coupled through homogeneous fine-grained actuation and sensor networks and play symmetric and complementary roles. We describe how these systems are fabricated, experimentally test their basic functionality, simulate their potential (e.g. for feed forward digital electrophoretic (FFDE) separation) and outline the application to building electronic chemical cells.


Subject(s)
Chemical Engineering/methods , Chemical Phenomena , Computers, Molecular/trends , Electronic Data Processing/methods , Chemical Engineering/trends , Electrodes , Electromagnetic Fields , Microcomputers , Microfluidic Analytical Techniques
5.
Artif Life ; 16(4): 311-28, 2010.
Article in English | MEDLINE | ID: mdl-20712511

ABSTRACT

The desire to start evolution from scratch inside a computer memory is as old as computing. Here we demonstrate how viable computer programs can be established de novo in a Precambrian environment without supplying any specific instantiation, just starting with random bit sequences. These programs are not self-replicators, but act much more like catalysts. The microcontrollers used in the end are the result of a long series of simplifications. The objective of this simplification process was to produce universal machines with a human-readable interface, allowing software and/or hardware evolution to be studied. The power of the instruction set can be modified by introducing a secondary structure-folding mechanism, which is a state machine, allowing nontrivial replication to emerge with an instruction width of only a few bits. This state-machine approach not only attenuates the problems of brittleness and encoding functionality (too few bits available for coding, and too many instructions needed); it also enables the study of hardware evolution as such. Furthermore, the instruction set is sufficiently powerful to permit external signals to be processed. This information-theoretic approach forms one vertex of a triangle alongside artificial cell research and experimental research on the creation of life. Hopefully this work helps develop an understanding of how information­in a similar sense to the account of functional information described by Hazen et al.­is created by evolution and how this information interacts with or is embedded in its physico-chemical environment.


Subject(s)
Enzymes/metabolism , Communication , Computer Simulation , Evolution, Molecular , Humans , Software , User-Computer Interface
6.
Syst Synth Biol ; 3(1-4): 65-75, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19816801

ABSTRACT

An alternative to creating novel organisms through the traditional "top-down" approach to synthetic biology involves creating them from the "bottom up" by assembling them from non-living components; the products of this approach are called "protocells." In this paper we describe how bottom-up and top-down synthetic biology differ, review the current state of protocell research and development, and examine the unique ethical, social, and regulatory issues raised by bottom-up synthetic biology. Protocells have not yet been developed, but many expect this to happen within the next five to ten years. Accordingly, we identify six key checkpoints in protocell development at which particular attention should be given to specific ethical, social and regulatory issues concerning bottom-up synthetic biology, and make ten recommendations for responsible protocell science that are tied to the achievement of these checkpoints.

SELECTION OF CITATIONS