1.
Br J Surg ; 107(6): 632-635, 2020 05.
Article in English | MEDLINE | ID: mdl-32246473

ABSTRACT

Probe electrospray ionization mass spectrometry (PESI-MS) is an ambient ionization-based mass spectrometry method that surpasses the original electrospray ionization technique in features such as the rapidity of analysis, simplicity of the equipment and procedure, and lower cost. This study found that the PESI-MS system with machine learning has the potential to establish a lipid-based diagnosis of breast cancer with higher accuracy, using a simpler approach. Rapid mass spectrometry for breast cancer.


Subject(s)
Biomarkers, Tumor/metabolism , Breast Neoplasms/diagnosis , Breast/metabolism , Lipid Metabolism , Spectrometry, Mass, Electrospray Ionization , Biopsy , Breast/pathology , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Case-Control Studies , Female , Humans , Logistic Models , Sensitivity and Specificity
2.
J Magn Reson Imaging ; 14(3): 319-28, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11536410

ABSTRACT

The purpose of this study was to develop a method for reducing gadolinium dose and suppressing venous overlap in moving-table three-dimensional (3D) magnetic resonance (MR) angiography from the abdomen to the feet. Thirty-one patients underwent three-phase infusion of 16-18 mL of gadolinium: infusion rates and imaging times were determined after taking into account mean blood flow velocity, so that image acquisition was synchronized with peak arterial enhancement at both the first and third stations (velocity-dependent method). Twenty-three other patients underwent slow infusion of 38 mL of gadolinium with fixed acquisition time (high-dose method). The image quality for the two methods was compared. The velocity-dependent method produced good image quality with significantly less venous overlap than the high-dose method, especially in the below-the-knee region (P <.001). The velocity-dependent method provides satisfactory MR angiograms using 16-18 mL of gadolinium in patients having various blood flow velocities.


Subject(s)
Arteries/pathology , Contrast Media/administration & dosage , Gadolinium/administration & dosage , Magnetic Resonance Angiography/methods , Adult , Aged , Aged, 80 and over , Blood Flow Velocity , Constriction, Pathologic/diagnosis , Female , Humans , Image Enhancement , Imaging, Three-Dimensional , Leg/blood supply , Male , Middle Aged , Models, Biological
3.
Radiology ; 219(1): 147-52, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11274549

ABSTRACT

PURPOSE: To investigate factors related to the development of internal mammary arteries (IMAs) as feeding arteries of hepatocellular carcinomas (HCCs). MATERIALS AND METHODS: In 30 patients with HCC located in ventral hepatic areas directly beneath the diaphragm, bilateral internal mammary arteriography was performed to explore involvement of the IMA with HCC. The number of previous transcatheter arterial embolizations (TAEs), tumor size, time from initial TAE to IMA angiography, inferior phrenic artery (IPA) involvement with tumor, presence of hepatic artery occlusion, and use of other treatments were compared in groups with and without involvement of the IMA. RESULTS: The group with IMA involvement included 10 patients; the group without involvement, 20 patients. TAE had been performed two to 12 times in the group with involvement and zero to six times in the group without involvement (P =.01). Mean tumor sizes in these two groups were 5.1 and 6.0 cm, respectively; hepatic artery occlusion was noted in nine and zero patients (P =.01) in the two groups. The time from initial TAE to IMA angiography ranged from 3 to 53 months (median, 31.5 months) and from zero to 89 months (median, 0 months) (P =.01). IPA involvement was observed in seven and four patients (P =.015). CONCLUSION: These results strongly suggest that, regardless of tumor size, when HCCs are located in the ventral hepatic areas directly beneath the diaphragm, the IMAs serve as feeding arteries in patients with hepatic artery occlusion caused by repeated TAE.


Subject(s)
Angiography , Carcinoma, Hepatocellular/blood supply , Liver Neoplasms/blood supply , Mammary Arteries/diagnostic imaging , Neoplastic Cells, Circulating , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/therapy , Embolization, Therapeutic , Female , Hepatic Artery/diagnostic imaging , Humans , Iodized Oil/therapeutic use , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Male , Middle Aged , Neoplasm Seeding , Risk Factors
4.
Nihon Igaku Hoshasen Gakkai Zasshi ; 60(5): 255-60, 2000 Apr.
Article in Japanese | MEDLINE | ID: mdl-10824533

ABSTRACT

The long-term results of transjugular intrahepatic portosystemic shunt(TIPS) were analyzed in 48 patients between February 1992 and December 1998, for treatment of esophageal varices and ascites caused by portal hypertension. The procedure was successful in 42 patients. Portal vein pressure was reduced from 29 mmHg +/- 7.9 to 19 mmHg +/- 7.3 immediately after TIPS and to 17 mmHg +/- 6.5 one year later. Varices were controlled in 82% (23/28) of patients after one year and in 78% (7/9) of patients after five years. Ascites disappeared or decreased in 79% (11/14) after one year. Primary shunt patency was 12%, with a secondary patency rate of 79% after five years. The overall incidence of new or worsened encephalopathy was 31% (13/42). Long-term follow-up showed one-, three-, and five-year survival rates of 82%, 68%, and 59%, respectively. TIPS is an effective means of lowering portal hypertension, and it controls varices and ascites with little risk of hepatic encephalopathy.


Subject(s)
Portasystemic Shunt, Transjugular Intrahepatic , Adult , Aged , Ascites/etiology , Ascites/surgery , Esophageal and Gastric Varices/etiology , Esophageal and Gastric Varices/surgery , Female , Follow-Up Studies , Humans , Hypertension, Portal/complications , Hypertension, Portal/surgery , Male , Middle Aged , Prognosis , Survival Rate , Time Factors
5.
Cardiovasc Intervent Radiol ; 23(1): 83A, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10656918

ABSTRACT

Purpose: The purpose of this study was to elucidate the clinical features of hepatocellular carcinoma (HCC) fed by the internal thoracic artery (ITA). Methods: In seven patients HCC fed by the ITA was confirmed by digital subtraction angiography. The number of previous transcatheter arterial embolization (TAE), the period from the first TAE to TAE of the ITA, tumor location, tumor size, and occlusion of the hepatic artery (HA) and other collateral vessels were explored in each case. Results: The HCCs were located in S4 of the liver (n = 5) and in S8 (n = 1) and were fed by the right ITA and one nodule in S2-3 was fed by the left ITA. Tumor size was 3-10 cm. The number of previous TAE of the HA ranged from 2 to 12. The period from the first TAE to TAE of the ITA was 3-53 months. Angiography of these patients showed occlusion of the HA in six cases, and of the extrahepatic collaterals including the inferior phrenic artery (IPA) in five cases, intercostal artery (ICA) in one case, and epicholedocal artery (EPA) in one case. Conclusion: The ITA often supplies HCC located in the anterior superior region of the liver under the diaphragm; there can be long-term survival with repeated TAE and occlusion of HA.

7.
Gan To Kagaku Ryoho ; 26(3): 353-6, 1999 Feb.
Article in Japanese | MEDLINE | ID: mdl-10065099

ABSTRACT

An 80-year-old woman with metastatic bone cancer from ascending colon showed a remarkable response to combination therapy of 5-FU and radiation. 5-FU (500 mg/day) was administered daily through intra-arterial catheter. The total dose of 5-FU was 15.5 g. Radiotherapy was performed (total radiation dose, 45 Gy). After therapy, metastatic lesions were remarkably reduced in size according to various imaging techniques, and the serum CEA level dramatically decreased from 249 ng/ml to 5.2 ng/ml. Other tumor markers such as CA19-9, NSE, and CYFRA were also dramatically decreased. Various tumor-related symptoms, especially the pain caused by tumor invasion, were also decreased. Drug toxicity caused slight nausea and leucopenia. These results suggested that the combination therapy of 5-FU and radiation is useful for the pain caused by metastatic bone cancer.


Subject(s)
Adenocarcinoma/secondary , Adenocarcinoma/therapy , Antimetabolites, Antineoplastic/administration & dosage , Bone Neoplasms/secondary , Bone Neoplasms/therapy , Colonic Neoplasms/therapy , Fluorouracil/administration & dosage , Adenocarcinoma/radiotherapy , Aged , Aged, 80 and over , Bone Neoplasms/radiotherapy , Colonic Neoplasms/pathology , Colonic Neoplasms/radiotherapy , Combined Modality Therapy , Female , Humans , Infusions, Intra-Arterial , Radiotherapy Dosage
8.
Nihon Igaku Hoshasen Gakkai Zasshi ; 59(14): 888-90, 1999 Dec.
Article in Japanese | MEDLINE | ID: mdl-10655715

ABSTRACT

Moving-table three-dimensional (3D) MR angiography provides images of long segments of arteries. However, deep veins are sometimes superimposed on the arteries below the knee, and peripheral arteries sometimes fail to be visualized. We have developed an imaging method with three-phase gadolinium infusion according to the mean blood flow velocity of the leg. Nineteen patients with various blood flow velocities were studied. Eighteen of the patients had no venous superimposition. All 19 patients showed good configuration of peripheral arteries with 16-18 ml of gadolinium. This method is useful for better visualization of peripheral arteries without venous superimposition.


Subject(s)
Contrast Media/administration & dosage , Gadolinium , Image Enhancement/methods , Infusions, Intravenous/methods , Magnetic Resonance Angiography/methods , Adult , Aged , Aged, 80 and over , Arterial Occlusive Diseases/diagnosis , Arterial Occlusive Diseases/pathology , Arteries/pathology , Blood Flow Velocity , Female , Gadolinium/administration & dosage , Humans , Leg/blood supply , Male , Middle Aged
9.
Radiology ; 205(1): 181-4, 1997 Oct.
Article in English | MEDLINE | ID: mdl-9314982

ABSTRACT

PURPOSE: To evaluate the use of impermeable silicone-covered Wallstents for transjugular intrahepatic portosystemic shunt creation. MATERIALS AND METHODS: A transjugular intrahepatic portosystemic shunt was created in 14 young swine (weight, 20-32 kg) by using impermeable silicone-covered Wallstents. In eight animals, the silicone covering extended from the portal vein to the inferior vena cava. In two swine, the silicone covering ended short of the inferior vena cava, in two it ended short of the portal vein wall, and in two it ended short at each end. Follow-up transhepatic portal venography was performed weekly for 6 weeks or until the shunt was occluded. Animals were then sacrificed for gross and histologic evaluation. RESULTS: Only two of 14 shunts were patent after 3 weeks; both were stenosed with luminal narrowing of more than 50% in the middle of the shunt. By 6 weeks, all shunts were occluded. At histologic evaluation, a marked foreign-body reaction with superimposed thrombosis was demonstrated. CONCLUSION: In comparison with uncovered Wallstents, impermeable silicone-covered Wallstents are associated with decreased patency at transjugular intrahepatic portosystemic shunt creation. This is likely due to increased thrombogenicity and a foreign-body reaction.


Subject(s)
Portasystemic Shunt, Transjugular Intrahepatic , Silicones , Stents , Animals , Portal Vein/diagnostic imaging , Portasystemic Shunt, Transjugular Intrahepatic/adverse effects , Radiography , Stents/adverse effects , Surface Properties , Swine , Thrombosis/etiology , Thrombosis/pathology
10.
Nihon Igaku Hoshasen Gakkai Zasshi ; 57(5): 233-7, 1997 Apr.
Article in Japanese | MEDLINE | ID: mdl-9164110

ABSTRACT

TIPS (transjugular intrahepatic portosystemic shunt) is an efficacious treatment for esophagogastric varices, ascites and hypertensive gastrointestinal vasculopathy associated with portal hypertension. The main complication after the procedure is hepatic encephalopathy. We tried to elucidate the correlation between hepatic encephalopathy and changes in portal hemodynamics after TIPS, based on observation by Doppler ultrasonography. We carried out Doppler ultrasonography in 28 cases of TIPS to assess hepatopetal and hepatofugal blood flow in the right and left portal branches. Hepatic encephalopathy occurred after TIPS in 9 cases out of 28 (32%), and new onset of disease was observed in 6 of 9. Doppler ultrasonography revealed hepatofugal blood flow in both right and left portal branches in 6 cases, 5 of which showed encephalopathy. Hepatopetal blood flow of the right and left portal branches was observed in 17 of 28 cases after TIPS. Hepatic encephalopathy occurred in only 2 of 17 cases. The changes in portal vein hemodynamics after TIPS were investigated by color Doppler ultrasonography, which were considered to be very useful for prediction of hepatic encephalopathy and indication of medical treatment to prevent the occurrence of this disease.


Subject(s)
Hepatic Encephalopathy/etiology , Hypertension, Portal/surgery , Liver Circulation , Liver Cirrhosis/complications , Portal System/physiopathology , Portasystemic Shunt, Transjugular Intrahepatic/adverse effects , Ultrasonography, Doppler, Color , Adult , Aged , Female , Hemodynamics , Hepatic Encephalopathy/diagnostic imaging , Humans , Male , Middle Aged , Portal System/diagnostic imaging
11.
J Vasc Interv Radiol ; 8(1 Pt 1): 123-8, 1997.
Article in English | MEDLINE | ID: mdl-9025051

ABSTRACT

PURPOSE: Creation of presinusoidal chronic portal venous hypertension by means of repeated portal vein (PV) embolization was explored in an attempt to improve a porcine model of transjugular intrahepatic portosystemic shunt (TIPS) patency. MATERIALS AND METHODS: Six microswine underwent weekly PV embolization for 5 weeks with a total of 10.4-12.6 g of polyvinyl alcohol (PVA) particles (0.149-0.250 mm in size). Portography, liver function tests, pressure measurement in the PV and inferior vena cava (IVC) before and after PV embolization, and histopathologic evaluation of the livers were performed. RESULTS: Transhepatic portal venography performed after each embolization demonstrated diffuse PV branch occlusion in all cases. At weekly follow-up, reconstitution of flow was demonstrated in these branches; permanent occlusion of PV branches was not achieved. The mean PV pressure elevated acutely from 17.3 mm Hg +/- 0.9 to 24.5 mm Hg +/- 4.2 (P < .01) after each embolization. However, the pressure always returned to baseline on the follow-up studies 1 week later. Liver function tests were normal. Histopathologic evaluation of the liver showed, in multiple PV branches, central plugs of PVA with peripheral recanalization. The liver parenchyma was otherwise normal. CONCLUSION: Massive embolizations of PV with PVA at weekly intervals failed to create permanent portal hypertension or induce hepatic fibrosis.


Subject(s)
Embolism/chemically induced , Hypertension, Portal/etiology , Polyvinyl Alcohol/toxicity , Portal Vein/drug effects , Animals , Blood Pressure , Chronic Disease , Disease Models, Animal , Embolism/complications , Embolism/pathology , Follow-Up Studies , Hypertension, Portal/pathology , Hypertension, Portal/physiopathology , Liver Function Tests , Portasystemic Shunt, Transjugular Intrahepatic , Portography , Swine , Swine, Miniature
12.
Nihon Igaku Hoshasen Gakkai Zasshi ; 56(6): 364-7, 1996 May.
Article in Japanese | MEDLINE | ID: mdl-8710457

ABSTRACT

TIPS (transjugular intrahepatic portosystemic shunt) is a new interventional radiologic procedure that is useful in the treatment of variceal bleeding and ascites due to portal hypertension. It is most important that the shunt remains patent for a long time after placement. The potential role of ultrasound in evaluating the patency of the shunt after TIPS has been studied. Duplex and color doppler sonography were performed in 20 patients with portal hypertension after TIPS. Imaging was done in 38 case. The findings were compared with those of follow-up angiography. Shunt patency was evaluated with Doppler US in 28 case. In 27 of them, the equivalent patent shunt was confirmed by angiography; the exception was one case of occlusion in follow-up angiography. Doppler signals in the shunt could not be detected in 10 cases. Follow-up angiography showed occlusion in 7 cases and patency in the other 3. Doppler US sensitivity was 90%, and its specificity was 88%. These results indicate that Doppler US is one of the most useful methods for evaluating shunt patency after TIPS.


Subject(s)
Portasystemic Shunt, Surgical , Ultrasonography, Doppler, Duplex , Vascular Patency , Adult , Aged , Esophageal and Gastric Varices/surgery , Female , Follow-Up Studies , Gastrointestinal Hemorrhage/surgery , Humans , Male , Middle Aged , Portasystemic Shunt, Surgical/methods , Predictive Value of Tests , Sensitivity and Specificity
13.
Nihon Geka Gakkai Zasshi ; 97(1): 83-8, 1996 Jan.
Article in Japanese | MEDLINE | ID: mdl-8868327

ABSTRACT

Thirty-five patients with portal hypertension due to liver cirrhosis secondary to chronic viral hepatitis underwent transjuglar intrahepatic portosystemic shunt for the last 3-year period. Shunts were successfully completed in 31 of 35 patients at 89%. Portal vein pressure was markedly reduced on average in the all cases until 6 months after TIPS. The endoscopic findings of varices much improved in 90% of the patients. Long-term patency rates of TIPS were 97% after 4 weeks, 79% after 6 months, 76% after a year and 55% after 2 years, respectively. The authors concluded that TIPS was an effective and reliable means of lowering portal pressure, improving endoscopic findings of varices and controlling of refractory ascites.


Subject(s)
Hypertension, Portal/surgery , Portasystemic Shunt, Surgical , Esophageal and Gastric Varices/pathology , Esophagoscopy , Humans , Hypertension, Portal/diagnostic imaging , Hypertension, Portal/physiopathology , Portal Pressure , Portasystemic Shunt, Surgical/instrumentation , Portasystemic Shunt, Surgical/methods , Radiography, Interventional
14.
Radiat Med ; 13(5): 259-61, 1995.
Article in English | MEDLINE | ID: mdl-8848563

ABSTRACT

We experienced a case of subarachnoid rupture of a spinal arteriovenous malformation (AVM) following the injection of contrast medium through a 3F wedged catheter inserted into the feeding artery. If blood does not come through the catheter in the feeding artery of a spinal AVM, not even test injection should be done, to avoid rupture of the spinal AVM.


Subject(s)
Arteriovenous Malformations/diagnostic imaging , Catheterization, Peripheral/adverse effects , Subarachnoid Hemorrhage/etiology , Angiography, Digital Subtraction , Catheterization, Peripheral/instrumentation , Embolization, Therapeutic/instrumentation , Humans , Male , Middle Aged , Rupture , Spinal Cord/blood supply , Tomography, X-Ray Computed
15.
Nihon Igaku Hoshasen Gakkai Zasshi ; 54(14): 1412-4, 1994 Dec 25.
Article in Japanese | MEDLINE | ID: mdl-7596770

ABSTRACT

Three types of modified Gianturco Z stents, which included some solder at the bend portion in group 1, a little solder in group 2 and no solder in group 3, were placed in the jugular vein in order to evaluate the degree of intimal hyperplasia growth in five dogs. Four weeks later, venography and histological examination after venectomy were performed. Stenosis was 32.7 +/- 6.9% at the bend portion in group 1, 27.0 +/- 6.0% in group 2 and 14.0 +/- 6.5% in group 3. The results indicate that stents without solder are preferable for the venous system.


Subject(s)
Jugular Veins/pathology , Stents/adverse effects , Animals , Dogs , Hyperplasia/etiology , Jugular Veins/diagnostic imaging , Radiography
SELECTION OF CITATIONS