1.
Talanta ; 65(3): 722-9, 2005 Feb 15.
Article in English | MEDLINE | ID: mdl-18969859

ABSTRACT

Design and development of a dynamic interfacial pressure detector (DIPD) is reported. The DIPD measures the differential pressure as a function of time across the liquid-liquid interface of organic liquid drops (i.e., n-hexane) that repeatedly grow in water at the end of a capillary tip. Using a calibration technique based on the Young-Laplace equation, the differential pressure signal is converted, in real-time, to a relative interfacial pressure. This allows the DIPD to monitor the interfacial tension of surface active species at liquid-liquid interfaces in flow-based analytical techniques, such as flow injection analysis (FIA), sequential injection analysis (SIA) and high performance liquid chromatography (HPLC). The DIPD is similar in principle to the dynamic surface tension detector (DSTD), which monitors the surface tension at the air-liquid interface. In this report, the interfacial pressure at the hexane-water interface was monitored as analytes in the hexane phase diffused to and arranged at the hexane-water interface. The DIPD was combined with FIA to analytically measure the interfacial properties of cholesterol and Brij((R))30 at the hexane-water interface. Results show that both cholesterol and Brij((R))30 exhibit a dynamic interfacial pressure signal during hexane drop growth. A calibration curve demonstrates that the relative interfacial pressure of cholesterol in hexane increases as the cholesterol concentration increases from 100 to 10,000mugml(-1). An example of the utility of the DIPD as a selective detector for a chromatographic separation of interface-active species is also presented in the analysis of cholesterol in egg yolk by normal-phase HPLC-DIPD.

2.
Talanta ; 64(5): 1241-6, 2004 Dec 15.
Article in English | MEDLINE | ID: mdl-18969736

ABSTRACT

A flow injection (FI) in-valve-mini-column packed with Chelex-100 resin is proposed for on-line sample pretreatment for some metal ions, namely, Cd(II), Pb(II) and Zn(II), prior to simultaneous determination using ion chromatography (IC). A solution containing a mixture of the cations was first passed through the in-valve-mini-column, followed by on-line elution. The eluate was then flowed further to an injection valve and was injected into an ion chromatograph. Conditions of the system were optimized. A single standard calibration was possible. The recoveries of cations were found to be in the range of 95-105%. The developed method was applied to the accurate analysis of zinc ore samples.

3.
Talanta ; 59(4): 809-16, 2003 Mar 10.
Article in English | MEDLINE | ID: mdl-18968968

ABSTRACT

A novel Raman sensor using a liquid-core optical waveguide is reported, implementing a Teflon-AF 2400 tube filled with water. An aqueous analyte mixture of benzene, toluene and p-xylene was introduced using a 1000 microl sample loop to the liquid-core waveguide (LCW) sensor and the analytes were preconcentrated on the inside surface of the waveguide tubing. The analytes were then eluted from the waveguide using an acetonitrile-water solvent mixture injected via a 30 microl eluting solvent loop. The preconcentration factor was experimentally determined to be 14-fold, in reasonable agreement with the theoretical preconcentration factor of 33 based upon the sample volume to elution volume ratio. Raman spectra of benzene, toluene and p-xylene were obtained during elution. It was found that analytically useful Raman signals for benzene, toluene and p-xylene were obtained at 992, 1004 and 1206 cm(-1), respectively. The relative standard deviation of the method was 3% for three replicate measurements. The limit of detection (LOD) was determined to be 730 ppb (parts per billion by volume) for benzene, exceptional for a system that does not resort to surface enhancement or resonance Raman approaches. The Raman spectra of these test analytes were evaluated for qualitative and quantitative analysis utility.