Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
3.
Blood Press ; 26(2): 94-101, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27601135

ABSTRACT

BACKGROUND: Abnormal P-wave terminal force in lead V1 (PTF-V1) is an ECG marker of increased left atrial (LA) volume, elevated LA filling pressures and/or LA systolic dysfunction. Because left ventricular (LV) diastolic dysfunction is one of the potential mechanisms driving LA remodelling, we hypothesized that PTF-V1 might be an additional ECG marker of diastolic dysfunction. METHODS: LV diastolic function after 3 years' systematic antihypertensive treatment was examined in relation to baseline PTF-V1 in 431 hypertensive patients undergoing protocol-driven blood pressure reduction who had baseline and year-3 ECG and echocardiographic data and a preserved LV ejection fraction (EF >45%) at year-3. Abnormal diastolic function was defined by the tenth or 90th percentile values from 405 normotensive, non-obese and non-diabetic adults without overt cardiovascular disease. Abnormal PTF-V1, defined by the presence of a negative terminal P-wave in lead V1 ≥ 4000 µV·ms, was present in 167 patients (38.7%). RESULTS: Abnormal PTF-V1 was associated with worse year-3 mean diastolic first third filling time (0.43 ± 0.08 vs 0.40 ± 0.07 sec, p = 0.039), first half filling time (0.55 ± 0.07 vs 0.53 ± 0.07 sec, p = 0.041), mitral valve A velocity (86 ± 27 vs 76 ± 19 cm/sec, p = 0.009) and mitral valve E/A ratio (0.85 ± 0.22 vs 0.94 ± 0.27, p = 0.007) after adjusting for other potential predictors of diastolic dysfunction including race, and heart rate, systolic blood pressure and severity of ECG LVH by Cornell product criteria at baseline. In parallel multivariate logistic regression analysis, abnormal PTF-V1 was associated with significantly increased odds of abnormal mitral valve E/A ratio (OR 1.55, 95%CI 1.04-2.32 p = 0.032), and a trend toward higher odds of abnormal half filling time (OR 1.42, 95%CI 0.94-2.15, p = 0.098) at year-3 of follow-up. CONCLUSIONS: Abnormal P-wave terminal force in lead V1 is associated with worse diastolic function and predicts abnormal LV diastolic behaviour in patients with preserved EF after 3 years of blood pressure reductive therapy.


Subject(s)
Atrial Remodeling , Blood Pressure , Electrocardiography , Hypertension/physiopathology , Ventricular Dysfunction, Left/physiopathology , Adult , Aged , Aged, 80 and over , Double-Blind Method , Female , Humans , Male , Middle Aged
4.
Blood Press ; 25(6): 364-372, 2016 12.
Article in English | MEDLINE | ID: mdl-27146272

ABSTRACT

BACKGROUND: Persistence or development of Cornell product left ventricular hypertrophy (LVH) is associated with increased heart failure (HF) risk that is partly explained by greater LV systolic dysfunction. However, whether new or persistent Cornell product LVH during antihypertensive treatment is associated with worse LV diastolic function is unclear. METHODS: Left ventricular diastolic function was examined in relation to year-3 ECG LVH in 377 hypertensive patients with a preserved LV ejection fraction (>45%) at year-3. Cornell product >2440 mm·ms defined ECG LVH. RESULTS: In multivariate models adjusting for age, sex, change from baseline to year-3 systolic blood pressure, and baseline and change from baseline to year-3 Sokolow-Lyon voltage, persistent or new Cornell product LVH at year-3 remained associated with year-3 abnormal half filling time (OR 1.63, 95% CI 1.04-2.55 p = 0.034), with a trend toward higher odds of abnormal third filling time (OR 1.51, 95% CI 0.087 p = 0.087) and total filling time (OR 1.79, CI 0.98-3.27 p = 0.059). CONCLUSION: In hypertensive patients undergoing antihypertensive therapy, persistence or development of Cornell product ECG LVH at year-3 follow-up is modestly associated with LV diastolic dysfunction. These findings suggest that diastolic dysfunction may be a mechanism via which changing ECG LVH influences HF risk.


Subject(s)
Hypertension , Hypertrophy, Left Ventricular , Antihypertensive Agents/therapeutic use , Electrocardiography , Humans , Losartan/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...