Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Catheter Cardiovasc Interv ; 100(7): 1302-1306, 2022 12.
Article in English | MEDLINE | ID: mdl-36321613

ABSTRACT

OBJECTIVES: We report a single-center experience in utilizing the transcaval-access transcatheter aortic valve implantation (TAVI) as an alternative approach in morbidly obese patients. BACKGROUND: Morbidly obese patients present frequently for TAVI. Transfemoral arterial access TAVI in these patients is technically challenging due to deep arterial access, resulting in a higher risk of vascular complications. Transcaval access TAVI is increasingly used in patients with prohibitive iliofemoral arterial access. METHODS: We used the transcaval approach for eight morbidly obese patients who had otherwise technically feasible femoral arterial access. This technique provides an alternative arterial access point that potentially circumvents some of the challenges relating to femoral arterial access. RESULTS: We report eight morbidly obese patients with a mean body mass index of 42.3 ± 6.2 kg/m2 who underwent transcaval access TAVI at our center (mean EuroScore II 2.47 ± 1.83%). The patient mean age was 70.3 ± 9.8 years; six were female. All eight patients underwent a successful and uncomplicated procedure. The median time to discharge was 2 days and all patients were alive at 30 days. CONCLUSIONS: Transcaval access TAVI is a feasible alternative for morbidly obese patients and may reduce vascular complications. Further data are required to evaluate the safety of this approach.


Subject(s)
Aortic Valve Stenosis , Obesity, Morbid , Transcatheter Aortic Valve Replacement , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Feasibility Studies , Obesity, Morbid/complications , Obesity, Morbid/diagnosis , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Femoral Artery/diagnostic imaging
2.
Catheter Cardiovasc Interv ; 99(1): E31-E37, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34676958

ABSTRACT

BACKGROUND: Selection of appropriate patients for transcatheter aortic valve implantation (TAVI) can be challenging. Many factors can influence post-procedure outcomes. Traditional surgical scoring systems do not discriminate effectively. Medical parameters and functional indices can characterize mortality risk. Mobility is an important predictive functional index but is largely defined using subjective criteria. AIM: To describe the relationship between mobility, objectively defined by the requirement for gait aids to ambulate, and all-cause 30-day and long-term mortality in patients undergoing TAVI. METHODS: Mobility aid use was assessed in 1444 consecutive patients undergoing TAVI in a single center. Patients were categorized into "unaided," "1-stick," and "higher aid" groups based on the Brighton Mobility Index. Mortality tracking was obtained via the NHS Spine Portal in February 2021. RESULTS: Patients were aged 82 (IQR 78-86). 66% of patients walked unaided, 26% walked with 1 stick, and 8% required more assistance (e.g., 2 sticks, a Rollator, a Zimmer frame, or a wheelchair). Overall 30-day mortality for the whole cohort was 3.5%; 1-year mortality was 12.2%. Mobility was a significant predictor of 30-day mortality (p = 0.025). Use of a higher aid was associated with a mortality odds ratio of 2.83 (95% CI: 1.39-5.74). Mobility was also a significant predictor of long-term mortality (p < 0.001). Odds ratios for 1-stick and higher aid groups were 1.45 (95% CI: 1.21-1.72) and 2.01 (95% CI: 1.55-2.60), respectively. CONCLUSION: Objective assessment of mobility by gait aid use predicts both short and long-term survival in patients undergoing TAVI. Increased dependence on mobility aids is associated with a worse prognosis.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Fluoroscopy , Humans , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
3.
Cardiovasc Revasc Med ; 40S: 148-153, 2022 07.
Article in English | MEDLINE | ID: mdl-34412989

ABSTRACT

INTRODUCTION: The Perceval Valve has been increasingly used in Surgical Aortic Valve Replacement (SAVR) recently due to ease of implantation. However, we have seen some cases of relatively early haemodynamic failure of the Perceval valve and these patients may then present for valve-in-valve transcatheter aortic valve implantation (ViV-TAVI). Experience of ViV-TAVI in the Perceval valve is limited. METHODS: We report our experience of VIV-TAVI in four cases of early-failing Perceval valves, two with stenosis and two with regurgitation. We also review the literature with regard to ViV-TAVI for this indication. RESULTS: Four patients aged between 66 and 78 years presented with Perceval valve dysfunction an average of 4.6 years following SAVR. All cases underwent Heart Team discussion and a ViV-TAVI procedure was planned thereafter. Strategies to ensure crossing through the centre of the valve and not outside any portion of the frame were found to be essential. Three patients had self-expanding valves implanted and one had a balloon-expandable prosthesis. The average aortic valve area (AVA) improved from 0.8 cm2 pre-procedure to 1.5 cm2 post-procedure*. The mean gradient (MG) improved from 35.5 mmHg (range 19.7-53 mmHg) pre-procedure to 14.8 mmHg (range 7-30 mmHg) post-procedure. In one patient a MG of 30 mmHg persisted following valve deployment. There were no significant peri-procedural complications. CONCLUSIONS: ViV-TAVI is a useful option for failed Perceval prostheses and appears safe and effective in this small series. Crossing inside the whole frame of the Perceval valve is essential.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Design , Prosthesis Failure , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
4.
Catheter Cardiovasc Interv ; 99(4): 1172-1180, 2022 03.
Article in English | MEDLINE | ID: mdl-34792842

ABSTRACT

BACKGROUND: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. METHODS: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. RESULTS: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. CONCLUSIONS: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Ireland , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United Kingdom
5.
J Invasive Cardiol ; 33(10): E761-E768, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34521771

ABSTRACT

OBJECTIVES: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves. Balloons may additionally be used with all valve types for pre- and postdilation. The relationships between valve mechanism, balloon use, and in-hospital mortality are not fully characterized. METHODS: Prospective data were collected on 4063 patients undergoing TAVR for aortic stenosis at 4 high-volume centers in the United Kingdom. In-hospital mortality was analyzed according to valve expansion mechanism, use of balloons for pre- and postdilation, and specific cause of death. RESULTS: Mean patient age was 83 ± 8 years. Implanted valves were self expanding (n = 2241; 55%), mechanically expanding (n = 1092; 27%), or balloon expandable (n = 727; 18%). In-hospital death occurred in 66 cases (1.6%). Thirty-six deaths (54.5%) were classified as implantation-related mortalities, with rates of 0.8%, 0.5%, and 1.7% (P=.04) among self-expanding, mechanically expanding, and balloon-expandable technologies, respectively. Patients who underwent balloon inflation at any stage of their procedure (n = 2556; 63%) had significantly higher implantation-related mortality than those who did not (1.3% vs 0.3%, respectively; P<.01). Balloon-expandable valve procedures were associated with significantly higher all-cause mortality (2.6% vs 1.4%; P=.02) and implantation-related mortality (1.7% vs 0.7%; P=.02) than non-balloon-expandable valve procedures. Balloon-related complications accounted for 18 cases (26%) of total in-hospital mortality, including all 12 cases (17.4%) of annular rupture and 5 cases (7.2%) of coronary occlusion. CONCLUSIONS: Balloon use for predilation, valve implantation, or postdilation was associated with an increased mortality risk. Balloon-related complications were the largest contributor to in-hospital mortality, comprising all cases of annular rupture and the majority of coronary occlusion cases.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/adverse effects , Heart Valve Prosthesis/adverse effects , Hospital Mortality , Humans , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 98(1): 170-175, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33713533

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is maturing as a treatment option and is now often undertaken during an unscheduled index hospital admission. The aim of this study was to look at procedural and mid-term outcomes of patients undergoing elective versus urgent in-hospital transcatheter aortic valve implantation. METHODS: We identified a total of 1,157 patients who underwent TAVI between November 2007 and November 2019 at the Sussex Cardiac Centre in the UK. We compared the demographics, procedural outcomes, 30-day and 1-year mortality between elective and urgent patients. Emergency and salvage TAVI cases were excluded. RESULTS: Of the 1,157 patients who underwent the procedure, 975 (84.3%) had elective while 182 (15.7%) had urgent TAVI. Predominant aortic stenosis was more frequent in elective patients (91.7% vs. 77.4%); p < .01), while predominant aortic regurgitation was seen more commonly in the urgent group (11.5% vs. 4.2%; p < .01). Implantation success was similar between the elective (99.1%) and urgent group (99.4%). In-hospital (1.65% vs. 1.3%: p .11), 30 day (3.5% vs. 3.3%: p .81) and 1 year (10.9% vs. 11%; p .81) mortality rates were similar in the elective and urgent groups, respectively. CONCLUSIONS: In contemporary practice, urgent TAVI undertaken on the index admission can be performed at similar risk to elective outpatient TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Hospitals , Humans , Risk Factors , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 97(7): E967-E972, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33351217

ABSTRACT

Iatrogenic femoral artery pseudoaneurysm is an infrequent but troublesome complication of vascular access during transcatheter aortic valve implantation. There are non-invasive, percutaneous and surgical treatment options for management of this complication. This case series report demonstrates a novel technique using an Amplatzer Duct Occluder II closure device to successfully treat iatrogenic common femoral pseudoaneurysm following transcatheter aortic valve implantation.


Subject(s)
Aneurysm, False , Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Cardiac Catheterization/adverse effects , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...