Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Sci (Basel) ; 13(8)2023 Apr 02.
Article in English | MEDLINE | ID: mdl-38240007

ABSTRACT

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

2.
Radiat Res ; 194(6): 594-599, 2020 12 01.
Article in English | MEDLINE | ID: mdl-32991725

ABSTRACT

In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future.


Subject(s)
Brain/radiation effects , Electrons , Radiotherapy Dosage , Radiotherapy/methods , Child , Feasibility Studies , Humans , Monte Carlo Method , Software
3.
Radiother Oncol ; 139: 28-33, 2019 10.
Article in English | MEDLINE | ID: mdl-31178058

ABSTRACT

Pluridirectional high-energy agile scanning electronic radiotherapy (PHASER) is next-generation medical linac technology for ultra-rapid highly conformal image-guided radiation, fast enough to "freeze" physiological motion, affording improved accuracy, precision, and potentially superior FLASH radiobiological therapeutic index. Designed for compactness, economy, and clinical efficiency, it is also intended to address barriers to global access to curative radiotherapy.


Subject(s)
Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Radiotherapy, High-Energy/methods , Radiotherapy, Image-Guided/methods , Humans , Particle Accelerators , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...