1.
Radiat Environ Biophys ; 57(4): 395-404, 2018 11.
Article in English | MEDLINE | ID: mdl-30298289

ABSTRACT

The aim of the present study was to review the available models developed for calculating red bone marrow dose in radioiodine therapy using clinical data. The study includes 18 patients (12 females and six males) with metastatic differentiated thyroid cancer. Radioiodine tracer of 73 ± 16 MBq 131I was orally administered, followed by blood sampling (2 ml) and whole-body scans (WBSs) done at several time points (2, 6, 24, 48, 72, and ≥ 96 h). Red bone marrow dose was estimated using the OLINDA/EXM 1.0, IDAC-Dose 2.1, and EANM models, the models developed by Shen and co-workers, Keizer and co-workers and Siegel and co-workers, and Traino and co-workers, as well as the single measurement model (SMM). The results were then compared to the standard reference model Revised Sgouros Model (RSM) reported by Wessels and co-workers. The mean dose deviations of the Traino, Siegel, Shen, Keizer, OLINDA/EXM, EANM, SMM, and IDAC-Dose 2.1 models from the RSM were - 17%, - 24%, 6%, - 29%, - 15%, 40%, 48%, and - 8%, respectively. The statistical analysis demonstrated no significant difference between the results obtained with the RSM and with those obtained with the Shen, Traino, OLINDA/EXM, and IDAC-Dose 2.1 models (t test; pvalue > 0.05). However, a significant difference was found between RSM doses and those obtained with the EANM, SMM, and Keizer models (t test; pvalue < 0.05). The correlation between red marrow dose from the SMM and EANM models was modest (R2 = 0.65), while the crossfire dose calculated with the OLINDA/EXM and IDAC-Dose 2.1 models were in good agreement with each other and with the reference model. The findings obtained indicate that most of the dosimetry models can be used for a reliable dosimetry, and the calculated total body doses can be considered as a reliable non-invasive option for a conservative activity planning. In addition, the excellent performance of the IDAC-Dose 2.1 model will be of particular importance for a practical and accurate dosimetry, with the advantages of allowing for the use of realistic advanced phantoms and updated dose fractions, and of providing information about the blood dose contribution to the red bone marrow.


Subject(s)
Bone Marrow/radiation effects , Iodine Radioisotopes/therapeutic use , Radiation Dosage , Female , Humans , Male , Middle Aged , Prospective Studies , Radiometry
2.
Korean J Radiol ; 16(6): 1276-82, 2015.
Article in English | MEDLINE | ID: mdl-26576117

ABSTRACT

OBJECTIVE: We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. MATERIALS AND METHODS: We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. RESULTS: The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. CONCLUSION: Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion.


Subject(s)
Fetus/radiation effects , Radiation Dosage , Female , Gestational Age , Head/radiation effects , Humans , Pregnancy , Radiation, Ionizing , Retrospective Studies , Risk , Software , Tomography, X-Ray Computed , Turkey
3.
Radiat Prot Dosimetry ; 156(1): 25-9, 2013.
Article in English | MEDLINE | ID: mdl-23535081

ABSTRACT

The aim of this study was to determine the external dose rate of iodine retention as a function of time in the bodies of thyroid cancer patients during their isolation period in the hospital. Urine samples were collected at 6th, 12th, 18th, 24th h and 2nd, 3rd, 4th, 5th d from 83 patients after oral administration of (131)I and counted. The external dose rates were also simultaneously determined at the same time points. Then, it was expressed as retained radioiodine body activity versus dose rate. Effective half life calculated from urine sample measurements was found as 18.4±1.8 h within the first 24 h and 64±2.7 h between 48 and 120 h. According to this results, the external dose rate (<20 µSv h(-1)), which patients could be discharged, was achieved after 48 h for 3700 and 5550 MBq, and after 72 h for 7400 MBq of (131)I treatments.


Subject(s)
Iodine Radioisotopes/therapeutic use , Radiometry/methods , Radiotherapy Dosage , Thyroid Neoplasms/radiotherapy , Adult , Aged , Female , Hospitalization , Humans , Iodine Radioisotopes/urine , Male , Middle Aged , Thyroid Gland/radiation effects , Thyroid Neoplasms/urine , Time Factors , Young Adult