Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Coll Cardiol ; 83(11): 1042-1055, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38385929

ABSTRACT

BACKGROUND: Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)-guided electrocardiographic imaging (ECGI) noninvasively maps cardiac structural and electrophysiological (EP) properties. OBJECTIVES: The purpose of this study was to establish whether in subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]-), ECGI detects early EP abnormality, and in overt HCM, whether the EP substrate relates to genetic status (G+/G-LVH+) and structural phenotype. METHODS: This was a prospective 211-participant CMR-ECGI multicenter study of 70 G+LVH-, 104 LVH+ (51 G+/53 G-), and 37 healthy volunteers (HVs). Local activation time (AT), corrected repolarization time, corrected activation-recovery interval, spatial gradients (GAT/GRTc), and signal fractionation were derived from 1,000 epicardial sites per participant. Maximal wall thickness and scar burden were derived from CMR. A support vector machine was built to discriminate G+LVH- from HV and low-risk HCM from those with intermediate/high-risk score or nonsustained ventricular tachycardia. RESULTS: Compared with HV, subclinical HCM showed mean AT prolongation (P = 0.008) even with normal 12-lead electrocardiograms (ECGs) (P = 0.009), and repolarization was more spatially heterogenous (GRTc: P = 0.005) (23% had normal ECGs). Corrected activation-recovery interval was prolonged in overt vs subclinical HCM (P < 0.001). Mean AT was associated with maximal wall thickness; spatial conduction heterogeneity (GAT) and fractionation were associated with scar (all P < 0.05), and G+LVH+ had more fractionation than G-LVH+ (P = 0.002). The support vector machine discriminated subclinical HCM from HV (10-fold cross-validation accuracy 80% [95% CI: 73%-85%]) and identified patients at higher risk of sudden cardiac death (accuracy 82% [95% CI: 78%-86%]). CONCLUSIONS: In the absence of LVH or 12-lead ECG abnormalities, HCM sarcomere gene mutation carriers express an aberrant EP phenotype detected by ECGI. In overt HCM, abnormalities occur more severely with adverse structural change and positive genetic status.


Subject(s)
Cardiomyopathy, Hypertrophic , Cicatrix , Humans , Prospective Studies , Cicatrix/pathology , Magnetic Resonance Imaging, Cine , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/genetics , Electrocardiography , Hypertrophy, Left Ventricular/diagnosis , Magnetic Resonance Imaging
2.
J Cardiovasc Magn Reson ; 25(1): 73, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38044439

ABSTRACT

BACKGROUND: Electrocardiographic imaging (ECGI) generates electrophysiological (EP) biomarkers while cardiovascular magnetic resonance (CMR) imaging provides data about myocardial structure, function and tissue substrate. Combining this information in one examination is desirable but requires an affordable, reusable, and high-throughput solution. We therefore developed the CMR-ECGI vest and carried out this technical development study to assess its feasibility and repeatability in vivo. METHODS: CMR was prospectively performed at 3T on participants after collecting surface potentials using the locally designed and fabricated 256-lead ECGI vest. Epicardial maps were reconstructed to generate local EP parameters such as activation time (AT), repolarization time (RT) and activation recovery intervals (ARI). 20 intra- and inter-observer and 8 scan re-scan repeatability tests. RESULTS: 77 participants were recruited: 27 young healthy volunteers (HV, 38.9 ± 8.5 years, 35% male) and 50 older persons (77.0 ± 0.1 years, 52% male). CMR-ECGI was achieved in all participants using the same reusable, washable vest without complications. Intra- and inter-observer variability was low (correlation coefficients [rs] across unipolar electrograms = 0.99 and 0.98 respectively) and scan re-scan repeatability was high (rs between 0.81 and 0.93). Compared to young HV, older persons had significantly longer RT (296.8 vs 289.3 ms, p = 0.002), ARI (249.8 vs 235.1 ms, p = 0.002) and local gradients of AT, RT and ARI (0.40 vs 0.34 ms/mm, p = 0,01; 0.92 vs 0.77 ms/mm, p = 0.03; and 1.12 vs 0.92 ms/mm, p = 0.01 respectively). CONCLUSION: Our high-throughput CMR-ECGI solution is feasible and shows good reproducibility in younger and older participants. This new technology is now scalable for high throughput research to provide novel insights into arrhythmogenesis and potentially pave the way for more personalised risk stratification. CLINICAL TRIAL REGISTRATION: Title: Multimorbidity Life-Course Approach to Myocardial Health-A Cardiac Sub-Study of the MRC National Survey of Health and Development (NSHD) (MyoFit46). National Clinical Trials (NCT) number: NCT05455125. URL: https://clinicaltrials.gov/ct2/show/NCT05455125?term=MyoFit&draw=2&rank=1.


Subject(s)
Heart , Magnetic Resonance Imaging , Aged , Female , Humans , Male , Feasibility Studies , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Reproducibility of Results , Adult , Middle Aged
3.
BMC Cardiovasc Disord ; 22(1): 140, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35365075

ABSTRACT

BACKGROUND: The life course accumulation of overt and subclinical myocardial dysfunction contributes to older age mortality, frailty, disability and loss of independence. The Medical Research Council National Survey of Health and Development (NSHD) is the world's longest running continued surveillance birth cohort providing a unique opportunity to understand life course determinants of myocardial dysfunction as part of MyoFit46-the cardiac sub-study of the NSHD. METHODS: We aim to recruit 550 NSHD participants of approximately 75 years+ to undertake high-density surface electrocardiographic imaging (ECGI) and stress perfusion cardiovascular magnetic resonance (CMR). Through comprehensive myocardial tissue characterization and 4-dimensional flow we hope to better understand the burden of clinical and subclinical cardiovascular disease. Supercomputers will be used to combine the multi-scale ECGI and CMR datasets per participant. Rarely available, prospectively collected whole-of-life data on exposures, traditional risk factors and multimorbidity will be studied to identify risk trajectories, critical change periods, mediators and cumulative impacts on the myocardium. DISCUSSION: By combining well curated, prospectively acquired longitudinal data of the NSHD with novel CMR-ECGI data and sharing these results and associated pipelines with the CMR community, MyoFit46 seeks to transform our understanding of how early, mid and later-life risk factor trajectories interact to determine the state of cardiovascular health in older age. TRIAL REGISTRATION: Prospectively registered on ClinicalTrials.gov with trial ID: 19/LO/1774 Multimorbidity Life-Course Approach to Myocardial Health- A Cardiac Sub-Study of the MCRC National Survey of Health and Development (NSHD).


Subject(s)
Cardiovascular Diseases , Magnetic Resonance Imaging , Aged , Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/epidemiology , Health Surveys , Heart , Humans , Myocardium
4.
Sensors (Basel) ; 21(2)2021 Jan 16.
Article in English | MEDLINE | ID: mdl-33467163

ABSTRACT

E-textiles reveal a new and hybrid sector of the industry that is created by the integration of electronic components or textile-based electronics in our daily life textile products. They are facing problems in terms of washability, reliability, and user acceptance. This manuscript explains the mechanical stresses acting during the washing process and their impact on e-textile systems. Different washing programs were investigated in terms of total process duration. This washing process duration is mainly divided into three diverse washing actions: low-speed rotation, high-speed rotation, and stop time. This investigation was performed to highlight the importance of the washing actions and their percentages in the total washing process. A piece of fabric with a flexible PCB (printed circuit board), equipped with an accelerometer with a Bluetooth communication device and a microcontroller, was placed in the washing machine to analyze the movement of fabric provoked by washing stresses. The PCB was used for fabric movements recording to determine the impact of mechanical stress on e-textile systems during the washing process. From the video analysis, it was concluded that the duration of the low-speed and high-speed rotation actions should be privileged comparing to the duration of the whole washing process. A power spectral density (PSD) analysis based on the accelerometer outputs was realized. Mechanical stresses at different frequencies were identified. Based on this analysis, it could be possible to improve the protocols of mechanical tests (Martindale and pilling box) used to simulate the mechanical stress applied to e-textile systems during the washing process.

5.
Sensors (Basel) ; 20(5)2020 Feb 26.
Article in English | MEDLINE | ID: mdl-32110967

ABSTRACT

Reliability and washability are major hurdles facing the e-textile industry nowadays. The main fear behind the product's rejection is the inability to ensure its projected life span. The durability of e-textiles is based on an approximate lifetime of both the electronics and textiles integrated into the product. A detailed analysis of the wash process and the possibility of predicting product behavior are key factors for new standards implementation. This manuscript is focused on the washability issues of different types of woven, knitted, and embroidered, textile-based ECG electrodes. These electrodes are used without the addition of any ionic gel to the skin to reduce impedance. They were subjected to up to 50 wash cycles with two different types of wash processes, and changes in surface resistance, as well as the quality of ECG waves, were observed To investigate the wash damages in detail, the proposed mechanical (Martindale and Pilling box) and chemical test methods were investigated. The electrodes which increased resistance after washing showed the same trend in the proposed test methods. Copper-based electrodes suffered the most severe damage and increased resistance, as was also visible in an SEM analysis. These proposed test methods can be used to predict robustness behavior without washing.


Subject(s)
Electrocardiography , Laundering , Skin , Textiles , Wearable Electronic Devices , Electrodes , Humans , Signal Processing, Computer-Assisted , Surface Properties
6.
Sensors (Basel) ; 19(2)2019 Jan 21.
Article in English | MEDLINE | ID: mdl-30669584

ABSTRACT

A development of washable PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) polyamide textile-based electrodes is an interesting alternative to the traditional Ag/AgCl disposable electrodes, usually used in clinical practice, helping to improve medical assessment and treatment before apparition or progress of patients' cardiovascular symptoms. This study was conducted in order to determine whether physical properties of PEDOT:PSS had a significant impact on the coated electrode's electrocardiogram (ECG) signal quality, particularly after 50 washing cycles in a domestic laundry machine. Tests performed, included the comparison of two PEDOT:PSS solutions, in term of viscosity with emphasis on wetting tests, including surface tension and contact angle measurements. In addition, polyamide textile fabrics were used as substrate to make thirty electrodes and to characterize the amount of PEDOT:PSS absorbed as a function of time. The results showed that surface tension of PEDOT:PSS had a significant impact on the wetting of polyamide textile fabric and consequently on the absorbed amount. In fact, lower values of surface tension of the solution lead to low values contact angles between PEDOT:PSS and textile fabric (good wettability). Before washing, no significant difference has been observed among signal-to-noise ratios measured (SNR) for coated electrodes by the two PEDOT:PSS solutions. However, after 50 washing cycles, SNR decreased strongly for electrodes coated by the solution that had low viscosity, since it contained less solid contents. That was confirmed by scanning electron microscopy images (SEM) and also by analyzing the color change of electrodes based on the calculation of CIELAB color space coordinates. Moreover, spectral power density of recorded ECG signals has been computed and presented. All cardiac waves were still visible in the ECG signals after 50 washing cycles. Furthermore, an experienced cardiologist considered that all the ECG signals acquired were acceptable. Accordingly, our newly developed polyamide textile-based electrodes seem to be suitable for long-term monitoring. The study also provided new insights into the better choice of PEDOT:PSS formulation as a function of a specific process in order to manufacture cheaper electrodes faster.


Subject(s)
Bridged Bicyclo Compounds, Heterocyclic/chemistry , Electrocardiography, Ambulatory , Polymers/chemistry , Polystyrenes/chemistry , Signal Processing, Computer-Assisted , Textiles , Electrodes , Nylons/chemistry , Signal-To-Noise Ratio , Solutions , Surface Tension , Wettability
7.
Sensors (Basel) ; 18(11)2018 Nov 12.
Article in English | MEDLINE | ID: mdl-30424488

ABSTRACT

Long-term monitoring of the electrical activity of the heart helps to detect the presence of potential dysfunctions, enabling the diagnosis of a wide range of cardiac pathologies. However, standard electrodes used for electrocardiogram (ECG) acquisition are not fully integrated into garments, and generally need to be used with a gel to improve contact resistance. This article is focused on the development of washable screen-printed cotton, with and without Lycra, textile electrodes providing a medical quality ECG signal to be used for long-term electrocardiography measurements. Several samples with different Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) concentrations were investigated. Silver-plated knitted fabric electrodes were also used for comparison, within the same process of ECG signal recording. The acquisition of ECG signals carried out by a portable medical device and a low-coast Arduino-based device on one female subject in a sitting position. Three textile electrodes were placed on the right and left forearms and a ground electrode was placed on the right ankle of a healthy female subject. Plastic clamps were applied to maintain electrodes on the skin. The results obtained with PEDOT:PSS used for electrodes fabrication have been presented, considering the optimal concentration required for medical ECG quality and capacity to sustain up to 50 washing cycles. All the ECG signals acquired and recorded, using PEDOT:PSS and silver-plated electrodes, have been reviewed by a cardiologist in order to validate their quality required for accurate diagnosis.

8.
Materials (Basel) ; 11(2)2018 Feb 07.
Article in English | MEDLINE | ID: mdl-29414849

ABSTRACT

A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

9.
Sensors (Basel) ; 17(4)2017 Mar 24.
Article in English | MEDLINE | ID: mdl-28338607

ABSTRACT

In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable and reliable smart textile systems are presented. The common point of the two approaches is the use of flexible conductive PCB in order to interface the miniaturized rigid (traditional) electronic devices to conductive threads and tracks within the textile flexible fabric and to connect them to antenna, textile electrodes, sensors, actuators, etc. The first approach consists in the use of TPU films (thermoplastic polyurethane) that are deposited by the press under controlled temperature and pressure parameters in order to protect the conductive thread and electrical contacts. The washability of conductive threads and contact resistances between flexible PCB and conductive threads are tested. The second approach is focused on the protection of the whole system-composed of a rigid electronic device, flexible PCB, and textile substrate-by a barrier made of latex. Three types of prototypes were realized and washed. Their reliabilities are studied.

SELECTION OF CITATIONS
SEARCH DETAIL
...