Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Cardiovasc Med ; 10: 1160242, 2023.
Article in English | MEDLINE | ID: mdl-37363094

ABSTRACT

Background: Smartwatches are commonly capable to record a lead-I-like electrocardiogram (ECG) and perform a photoplethysmography (PPG)-based atrial fibrillation (AF) detection. Wearable technologies repeatedly face the challenge of frequent premature beats, particularly in target populations for screening of AF. Objective: To investigate the potential diagnostic benefit of six-lead ECG compared to single-lead ECG and PPG-based algorithm for AF detection of the wrist-worn device. Methods and results: From the database of DoubleCheck-AF 249 adults were enrolled in AF group (n = 121) or control group of SR with frequent premature ventricular (PVCs) or atrial (PACs) contractions (n = 128). Cardiac rhythm was monitored using a wrist-worn device capable of recording continuous PPG and simultaneous intermittent six-lead standard-limb-like ECG. To display a single-lead ECG, the six-lead ECGs were trimmed to lead-I-like ECGs. Two diagnosis-blinded cardiologists evaluated reference, six-lead and single-lead ECGs as "AF", "SR", or "Cannot be concluded". AF detection based on six-lead ECG, single-lead ECG, and PPG yielded a sensitivity of 99.2%, 95.7%, and 94.2%, respectively. The higher number of premature beats per minute was associated with false positive outcomes of single-lead ECG (18.80 vs. 5.40 beats/min, P < 0.01), six-lead ECG (64.3 vs. 5.8 beats/min, P = 0.018), and PPG-based detector (13.20 vs. 5.60 beats/min, P = 0.05). Single-lead ECG required 3.4 times fewer extrasystoles than six-lead ECG to result in a false positive outcome. In a control subgroup of PACs, the specificity of six-lead ECG, single-lead ECG, and PPG dropped to 95%, 83.8%, and 90%, respectively. The diagnostic value of single-lead ECG (AUC 0.898) was inferior to six-lead ECG (AUC 0.971) and PPG-based detector (AUC 0.921). In a control subgroup of PVCs, the specificity of six-lead ECG, single-lead ECG, and PPG was 100%, 96.4%, and 96.6%, respectively. The diagnostic value of single-lead ECG (AUC 0.961) was inferior to six-lead ECG (AUC 0.996) and non-inferior to PPG-based detector (AUC 0.954). Conclusions: A six-lead wearable-recorded ECG demonstrated the superior diagnostic value of AF detection compared to a single-lead ECG and PPG-based AF detection. The risk of type I error due to the widespread use of smartwatch-enabled single-lead ECGs in populations with frequent premature beats is significant.

2.
Am J Med ; 135(7): e165-e181, 2022 07.
Article in English | MEDLINE | ID: mdl-35245495

ABSTRACT

PURPOSE: This study was designed to evaluate the role of biologically active adrenomedullin (bio-ADM) in congestion assessment and risk stratification in acute dyspnea. METHODS: This is a sub-analysis of the Lithuanian Echocardiography Study of Dyspnea in Acute Settings. Congestion was assessed by means of clinical (peripheral edema, rales) and sonographic (estimated right atrial pressure) parameters. Ninety-day mortality was chosen for outcome analysis. RESULTS: There were 1188 patients included. Bio-ADM concentration was higher in patients with peripheral edema at admission (48.2 [28.2-92.6] vs 35.4 [20.9-59.2] ng/L, P < .001). There was a stepwise increase in bio-ADM concentration with increasing prevalence of rales: 29.8 [18.8-51.1], 38.5 [27.5-67.1], and 51.1 [33.1-103.2] ng/L in patients with no rales, rales covering less than one-half, and greater than or equal to one-half of the pulmonary area, respectively (P < 0.001). Bio-ADM concentration demonstrated gradual elevation in patients with normal, moderately, and severely increased estimated right atrial pressure: 25.1 [17.6-42.4] ng/L, 36.1 [23.1-50.2], and 47.1 [30.7-86.7] ng/L, respectively (P < .05). Patients with bio-ADM concentration >35.5 ng/L were at more than twofold increased risk of dying (P < .001). Survival in those with high bio-ADM was significantly modified by neurohormonal blockade at admission (P < .05), especially if NT-proBNP levels were lower than the median (P = .002 for interaction). CONCLUSION: Bio-ADM reflects the presence and the degree of pulmonary, peripheral, and intravascular volume overload and is strongly related to 90-day mortality in acute dyspnea. Patients with high bio-ADM levels demonstrated survival benefit from neurohormonal blockade.


Subject(s)
Adrenomedullin , Respiratory Sounds , Biomarkers , Dyspnea/etiology , Humans , Patient Selection
SELECTION OF CITATIONS
SEARCH DETAIL
...