1.
Infect Control Hosp Epidemiol ; 45(2): 260-262, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37675506

ABSTRACT

Hospitals caring for patients with high-consequence pathogens may need to safely manage large volumes of category A waste. Using biological indicators to assess for successful sterilization, autoclave cycle parameters that would inactivate 4 categories of waste were identified and validated utilizing a STERIS Amsco 630LS Steam Sterilizer.


Subject(s)
Communicable Diseases , Medical Waste , Humans , Steam , Sterilization , Hospitals