Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Surg Innov ; 12(4): 339-44, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16424955

ABSTRACT

The development of operative laparoscopic surgery is linked to advances in ancillary surgical instrumentation. Ultrasonic energy devices avoid the use of electricity and provide effective control of small- to medium-sized vessels. Bipolar computer-controlled electrosurgical technology eliminates the disadvantages of electrical energy, and a mechanical blade adds a cutting action. This instrument can provide effective hemostasis of large vessels up to 7 mm. Such devices significantly increase the cost of laparoscopic procedures, however, and the amount of evidence-based information on this topic is surprisingly scarce. This study compared the effectiveness of three different energy sources on the laparoscopic performance of a left colectomy. The trial included 38 nonselected patients with a disease of the colon requiring an elective segmental left-sided colon resection. Patients were preoperatively randomized into three groups. Group I had electrosurgery; vascular dissection was performed entirely with an electrosurgery generator, and vessels were controlled with clips. Group II underwent computer-controlled bipolar electrosurgery; vascular and mesocolon section was completed by using the 10-mm Ligasure device alone. In group III, 5-mm ultrasonic shears (Harmonic Scalpel) were used for bowel dissection, vascular pedicle dissection, and mesocolon transection. The mesenteric vessel pedicle was controlled with an endostapler. Demographics (age, sex, body mass index, comorbidity, previous surgery and diagnoses requiring surgery) were recorded, as were surgical details (operative time, conversion, blood loss), additional disposable instruments (number of trocars, EndoGIA charges, and clip appliers), and clinical outcome. Intraoperative economic costs were also evaluated. End points of the trial were operative time and intraoperative blood loss, and an intention-to-treat principle was followed. The three groups were well matched for demographic and pathologic features. Surgical time was significantly longer in patients operated on with conventional electrosurgery vs the Harmonic Scalpel or computed-based bipolar energy devices. This finding correlated with a significant reduction in intraoperative blood loss. Conversion to other endoscopic techniques was more frequent in Group I; however, conversion to open surgery was similar in all three groups. No intraoperative accident related to the use of the specific device was observed in any group. Immediate outcome was similar in the three groups, without differences in morbidity, mortality, or hospital stay. Analysis of operative costs showed no significant differences between the three groups. High-energy power sources specifically adapted for endoscopic surgery reduce operative time and blood loss and may be considered cost-effective when left colectomy is used as a model.


Subject(s)
Colectomy/methods , Colonic Diseases/surgery , Electrosurgery/economics , Laparoscopy/methods , Surgery, Computer-Assisted/economics , Ultrasonic Therapy/economics , Adult , Aged , Aged, 80 and over , Colectomy/economics , Costs and Cost Analysis , Dissection/economics , Female , Humans , Laparoscopy/economics , Male , Middle Aged , Treatment Outcome
2.
Semin Laparosc Surg ; 11(3): 161-9, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15510311

ABSTRACT

The success of laparoscopic fundoplication has extended the use of the laparoscopic approach to treating more difficult situations such as paraesophageal hernias (PEHs) or type III (mixed) hiatal hernia. The results have shown that laparoscopic repair is feasible and safe. However, several series have shown recurrence rates of up to 42% as a result of difficulty in the closure of the hiatal gap. Some authors recommend the use of prosthetic mesh to reinforce the hiatal closure. This review analyses the different techniques proposed to prevent recurrence after laparoscopic repair of PEHs. The information currently available shows that the use of a mesh for hiatal repair is safe and prevents recurrence. However, data on the long-term results are lacking, and infrequent but severe complications may arise. The mesh should be used selectively, and the decision to proceed should be based on clinical experience.


Subject(s)
Hernia, Hiatal/surgery , Laparoscopy , Fundoplication , Humans , Polytetrafluoroethylene , Postoperative Complications , Recurrence , Surgical Mesh
3.
Semin Laparosc Surg ; 11(3): 185-90, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15510314

ABSTRACT

Laparoscopic splenectomy in cases of splenomegaly has been shown to be feasible in experienced hands, even though the size of the spleen increases the operative time and difficulty. Laparoscopic splenectomy for splenomegaly offers the same advantages as for patients with smaller spleens: a shorter hospital stay and a faster recovery. Recent experience has shown that hand-assisted laparoscopic surgery makes the surgical maneuvers during laparoscopic splenectomy in cases of splenomegaly considerably easier while preserving the advantages of a purely laparoscopic approach. This technique may facilitate and broaden the application of laparoscopy for splenectomy in patients with enlarged spleens.


Subject(s)
Laparoscopy , Splenectomy/methods , Splenomegaly/surgery , Humans , Laparoscopy/methods , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...