Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
J Funct Biomater ; 14(3)2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36976080

ABSTRACT

Novel designs of porous and semi-porous hip stems attempt to alleviate complications such as aseptic loosening, stress shielding, and eventual implant failure. Various designs of hip stems are modeled to simulate biomechanical performance using finite element analysis; however, these models are computationally expensive. Therefore, the machine learning approach is incorporated with simulated data to predict the new biomechanical performance of new designs of hip stems. Six types of algorithms based on machine learning were employed to validate the simulated results of finite element analysis. Afterwards, new designs of semi-porous stems with outer dense layers of 2.5 and 3 mm and porosities of 10-80% were used to predict the stiffness of the stems, stresses in outer dense layers, stresses in porous sections, and factor of safety under physiological loads using machine learning algorithms. It was determined that decision tree regression is the top-performing machine learning algorithm as per the used simulation data in terms of the validation mean absolute percentage error which equals 19.62%. It was also found that ridge regression produces the most consistent test set trend as compared with the original simulated finite element analysis results despite relying on a relatively small data set. These predicted results employing trained algorithms provided the understanding that changing the design parameters of semi-porous stems affects the biomechanical performance without carrying out finite element analysis.

2.
Materials (Basel) ; 15(3)2022 Jan 30.
Article in English | MEDLINE | ID: mdl-35161029

ABSTRACT

Regarding crashworthiness, many published works have focused on designing thin-walled structures for frontal collisions compared to side-impact collisions. This paper presents an experimental investigation and finite element modelling of a carbon-reinforced thin-walled top-hat section subjected to quasi-static and dynamic transverse bending loads at different impact speeds. The top-hat sections and their closure assembly plates were made of MTM44 prepreg carbon. The specimens were manufactured by vacuum bagging. Dynamic work was performed to validate the results obtained from the finite element analysis (FEA). The predicted results are in good agreement with the experimental results. The study also showed that the peak load and energy absorption owing to dynamic loading were higher than those under static loading. In the four-point bend analysis, the stacking sequence affected the energy absorption capabilities by 15-30%. In addition, the distance between the indenters in the four-point analysis also affected the energy absorption by 10% for the same impact condition, where a larger distance promoted higher energy absorption. The study also demonstrated that a top-hat shaped thin-walled structure is suitable for deep intrusion beams in vehicle doors for side-impact crashworthiness applications.

3.
Article in English | MEDLINE | ID: mdl-35010775

ABSTRACT

Young drivers are generally associated with risky driving behaviors that can lead to crash involvement. Many self-report measurement scales are used to assess such risky behaviors. This study is aimed to understand the risky driving behaviors of young adults in Qatar and how such behaviors are associated with crash involvement. This was achieved through the usage of validated self-report measurement scales adopted for the Arabic context. A nationwide cross-sectional and exploratory study was conducted in Qatar from January to April 2021. Due to the Covid-19 pandemic, the survey was conducted online. Therefore, respondents were selected conveniently. Hence, the study adopted a non-probability sampling method in which convenience and snowball sampling were used. A total of 253 completed questionnaires were received, of which 57.3% were female, and 42.7% were male. Approximately 55.8% of these young drivers were involved in traffic accidents after obtaining their driving license. On average, most young drivers do have some risky driving behavior accompanied by a low tendency to violate traffic laws, and their driving style is not significantly controlled by their personality on the road. The older young drivers are more involved in traffic accidents than the younger drivers, i.e., around 1.5 times more likely. Moreover, a young male driver is 3.2 times less likely to be involved in traffic accidents than a female driver. In addition, males are only 0.309 times as likely as females to be involved in an accident and have approximately a 70% lower likelihood of having an accident versus females. The analysis is complemented with the association between young drivers' demographic background and psychosocial-behavioral parameters (linking risky driving behavior, personality, and obligation effects on crash involvement). Some interventions are required to improve driving behavior, such as driving apps that are able to monitor and provide corrective feedback.


Subject(s)
Automobile Driving , COVID-19 , Accidents, Traffic , Cross-Sectional Studies , Female , Humans , Male , Pandemics , Qatar/epidemiology , Risk-Taking , SARS-CoV-2 , Surveys and Questionnaires , Young Adult
4.
Materials (Basel) ; 14(16)2021 Aug 22.
Article in English | MEDLINE | ID: mdl-34443255

ABSTRACT

It is crucial that proper engineering structures are designed as energy absorbers for high dynamic loading situations, such as accidents, blasts, or impacts. The role of such structures is to absorb the high kinetic energy as strain energy through irreversible deformation of the structure. Many types of energy absorbers were designed for different dynamic high strain rate applications. One of these structures are sandwich structures. The aim of this review paper is to provide a general review on the type of sandwich structures that have been designed as energy absorbers and their performance in crashworthiness and blast related applications. The focus is on the type of core structures being used, namely foam and architected cores. It was found from the review that sandwich structures are viable candidates for such applications not only because of their light weight, but also due to the high-energy absorption capabilities. The work presented in this review paper shows that the data from the literature on this topic are vast and do not converge to any particular sandwich structure design. This presents the potential future research direction in designing sandwich structures, which have wider application at different scales.

5.
Front Pharmacol ; 12: 646836, 2021.
Article in English | MEDLINE | ID: mdl-33912058

ABSTRACT

Technological advances in science over the past century have paved the way for remedial treatment outcomes in various diseases. Pharmacogenomic predispositions, the emergence of multidrug resistance, medication and formulation errors contribute significantly to patient mortality. The concept of "personalized" or "precision" medicines provides a window to addressing these issues and hence reducing mortality. The emergence of three-dimensional printing of medicines over the past decades has generated interests in therapeutics and dispensing, whereby the provisions of personalized medicines can be built within the framework of producing medicines at dispensaries or pharmacies. This plan is a good replacement of the fit-for-all modality in conventional therapeutics, where clinicians are constrained to prescribe pre-formulated dose units available on the market. However, three-dimension printing of personalized medicines faces several hurdles, but these are not insurmountable. In this review, we explore the relevance of personalized medicines in therapeutics and how three-dimensional printing makes a good fit in current gaps within conventional therapeutics in order to secure an effective implementation of personalized medicines. We also explore the deployment of three-dimensional printing of personalized medicines based on practical, legal and regulatory provisions.

6.
J Mater Sci Mater Med ; 31(9): 78, 2020 Aug 20.
Article in English | MEDLINE | ID: mdl-32816091

ABSTRACT

The current study is proposing a design envelope for porous Ti-6Al-4V alloy femoral stems to survive under fatigue loads. Numerical computational analysis of these stems with a body-centered-cube (BCC) structure is conducted in ABAQUS. Femoral stems without shell and with various outer dense shell thicknesses (0.5, 1.0, 1.5, and 2 mm) and inner cores (porosities of 90, 77, 63, 47, 30, and 18%) are analyzed. A design space (envelope) is derived by using stem stiffnesses close to that of the femur bone, maximum fatigue stresses of 0.3σys in the porous part, and endurance limits of the dense part of the stems. The Soderberg approach is successfully employed to compute the factor of safety Nf > 1.1. Fully porous stems without dense shells are concluded to fail under fatigue load. It is thus safe to use the porous stems with a shell thickness of 1.5 and 2 mm for all porosities (18-90%), 1 mm shell with 18 and 30% porosities, and 0.5 mm shell with 18% porosity. The reduction in stress shielding was achieved by 28%. Porous stems incorporated BCC structures with dense shells and beads were successfully printed.


Subject(s)
Alloys/chemistry , Femur/pathology , Models, Theoretical , Porosity , Printing, Three-Dimensional , Titanium/chemistry , Biocompatible Materials/chemistry , Body Weight , Bone and Bones/pathology , Compressive Strength , Computer Simulation , Elastic Modulus , Finite Element Analysis , Humans , Materials Testing , Pressure , Prosthesis Design , Reproducibility of Results , Research Design , Stress, Mechanical
7.
Biomech Model Mechanobiol ; 19(6): 2213-2226, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32388685

ABSTRACT

The coated porous section of stem surface is initially filled with callus that undergoes osseointegration process, which develops a bond between stem and bone, lessens the micromotions and transfers stresses to the bone, proximally. This phenomenon attributes to primary and secondary stabilities of the stems that exhibit trade-off the stem stiffness. This study attempts to ascertain the influence of stem stiffness on peri-prosthetic bone formation and stress shielding when in silico models of solid CoCr alloy and Ti alloy stems, and porous Ti stems (53.8 GPa and 31.5 GPa Young's moduli) were implanted. A tissue differentiation predictive mechanoregulation algorithm was employed to estimate the evolutionary bond between bone and stem interfaces with 0.5-mm- and 1-mm-thick calluses. The results revealed that the high stiffness stems yielded higher stress shielding and lower micromotions than that of low stiffness stems. Contrarily, bone formation around solid Ti alloy stem and porous Ti 53.8 GPa stem was augmented in 0.5-mm- and 1-mm-thick calluses, respectively. All designs of stems exhibited different rates of bone formation, diverse initial micromotions and stress shielding; however, long-term bone formation was coherent with different stress shielding. Therefore, contemplating the secondary stability of the stems, low stiffness stem (Ti 53.8 GPa) gave superior biomechanical performance than that of high stiffness stems.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Femur/anatomy & histology , Hip Prosthesis , Prosthesis Design , Algorithms , Alloys , Arthroplasty, Replacement, Hip/methods , Biomechanical Phenomena , Bone and Bones/physiopathology , Compressive Strength , Computer Simulation , Elastic Modulus , Femur/physiopathology , Finite Element Analysis , Humans , Metals , Osseointegration , Phenotype , Pressure , Software , Stress, Mechanical , Titanium/chemistry
8.
Materials (Basel) ; 13(3)2020 Feb 03.
Article in English | MEDLINE | ID: mdl-32028584

ABSTRACT

Extensive research focus had been given to sacrificial sandwich panels to mitigate the effects of blast loads. This is due to their ability to distribute the load and absorb a significant portion of the blast energy. This paper studies the behavior of sacrificial sandwich mild steel panels of axially oriented octagonal tapered tubular cores subjected to near-field impulsive blast. The deformation behavior and several assessment parameters consisting of the peak force, stroke efficiency, energy absorption and core efficiency were investigated using validated finite element analysis. The developed deformation modes were mainly influenced by the top plate and tube thickness. Tubes of a 5° taper performed unfavorably, exhibiting increased peak force and lower energy absorption. Panels of top plate thickness of 4 mm exhibited higher stroke efficiency as compared to panels of lower thickness. The top plate and tube thickness significantly affected energy absorption. An increase of 73.5% in core efficiency was observed in thick-plate panels as compared to thin-plate ones.

9.
Artif Organs ; 43(7): E152-E164, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30805945

ABSTRACT

The mismatch between stiffness of the femoral dense stem and host bone causes complications to patients, such as aseptic loosening and bone resorption. Three-dimensional finite-element models of homogeneous porous (HGP) and functionally graded porous (FGP) stems incorporating body-centered cubic (BCC) structures are proposed in this article as an alternative to the dense stems. The relationship between the porosity and strut thickness of the BCC structure was developed to construct the finite-element models. Three levels of porosities (20%, 50%, and 80%) were modeled in HGP and FGP stems. The porosity of the stems was decreased distally according to the sigmoid function (n = 0.1, n = 1 and n = 10) with 3 grading exponents. The results showed that FGP stems transferred 120%-170% higher stresses to the femur (Gruen zone 7) as compared to the solid stem. Conversely, the stresses in HGP and FGP stems were 12%-34% lower than the dense stem. The highest micromotions (105-147 µm) were observed for stems of 80% overall porosity, and the lowest (42-46 µm) was for stems of 20% overall porosity. Finally, FGP stems with a grading exponent of n = 10 resulted in an 11%-28% reduction in micromotions.


Subject(s)
Computer-Aided Design , Femur/anatomy & histology , Hip Prosthesis , Biomechanical Phenomena , Finite Element Analysis , Humans , Models, Anatomic , Porosity , Prosthesis Design , Stress, Mechanical
10.
Nanomaterials (Basel) ; 8(8)2018 Aug 09.
Article in English | MEDLINE | ID: mdl-30096855

ABSTRACT

Herein, we report the synthesis of silver-cobalt nanopowders using three different modes of solution combustion synthesis, and we present the effects of the synthesis conditions on particle morphology. The synthesized nanoparticles were characterized using X-ray diffraction (XRD), Scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), UV-Visible spectrophotometer (UV-vis), Transmission electron microscopy (TEM), and X-Ray Photoelectron Spectroscopy (XPS) to understand the structural and elemental properties. When Co is synthesized over Ag in a second wave of combustion, peak shifts observed in XRD and XPS show a change in the cell parameters and prove the existence of a strong electronic interaction between Ag and Co. Better control of mixing and alloying through the second wave combustion synthesis mode (SWCS) was evident. The sequence of combustion affects the structure and composition of the material. SWCS reduces the amount of carbon content, as compared to single-stage combustion, and the combustion of carbon is followed by a rearrangement of atoms.

11.
ACS Omega ; 3(7): 7745-7756, 2018 Jul 31.
Article in English | MEDLINE | ID: mdl-31458922

ABSTRACT

Ag/Co3O4 catalysts using three different modes of solution combustion synthesis were developed and characterized by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy to identify crystallite size, oxidation state, composition, and morphology. Cyclic voltammetry and linear sweep voltammetry measurements for the oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) confirm the bifunctionality of the electrocatalysts. The electrochemical evaluation indicates that a synergic effect between Ag and Co enhances the activity through the fast breaking of O-O bond in the molecular oxygen to enhance the reduction mechanism. The high content of cobalt (Co) in the catalyst Ag/Co3O4-12, synthesized by second wave combustion, improves the activity for ORR, and the reaction mechanism follows a 3.9 number of electron transfer in overall reaction. The kinetic and limiting current densities of Ag/Co3O4-12 are maximum when compared to those of other Ag/Co3O4 catalysts and are very close to commercial Pt/C. Moreover, the maximum current density of OER for Ag/Co3O4-12 makes it a promising candidate for various bifunctional electrocatalytic applications such as fuel cells and metal-air batteries.

12.
Biomech Model Mechanobiol ; 17(3): 701-716, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29168071

ABSTRACT

Cementless hip prostheses with porous outer coating are commonly used to repair the proximally damaged femurs. It has been demonstrated that stability of prosthesis is also highly dependent on the bone ingrowth into the porous texture. Bone ingrowth is influenced by the mechanical environment produced in the callus. In this study, bone ingrowth into the porous structure was predicted by using a mechano-regulatory model. Homogenously distributed pores (200 and 800 [Formula: see text]m in diameter) and functionally graded pores along the length of the prosthesis were introduced as a porous coating. Bone ingrowth was simulated using 25 and 12 [Formula: see text]m micromovements. Load control simulations were carried out instead of traditionally used displacement control. Spatial and temporal distributions of tissues were predicted in all cases. Functionally graded pore decreasing models gave the most homogenous bone distribution, the highest bone ingrowth (98%) with highest average Young's modulus of all tissue phenotypes approximately 4.1 GPa. Besides this, the volume of the initial callus increased to 8.33% in functionally graded pores as compared to the 200 [Formula: see text]m pore size models which increased the bone volume. These findings indicate that functionally graded porous surface promote bone ingrowth efficiently which can be considered to design of surface texture of hip prosthesis.


Subject(s)
Algorithms , Bone Cements/pharmacology , Finite Element Analysis , Hip Prosthesis , Osteogenesis , Biomechanical Phenomena , Bony Callus/pathology , Computer Simulation , Elastic Modulus , Models, Biological , Movement , Phenotype , Porosity
13.
IEEE Trans Biomed Eng ; 63(8): 1573-80, 2016 08.
Article in English | MEDLINE | ID: mdl-27214884

ABSTRACT

Glaucoma is a neurological disorder leading to blindness initially through the loss of retinal ganglion cells, followed by loss of neurons higher in the visual system. Some work has been undertaken to develop prostheses for glaucoma patients targeting tissues along the visual pathway, including the lateral geniculate nucleus (LGN) of the thalamus, but especially the visual cortex. This review makes the case for a visual prosthesis that targets the LGN. The compact nature and orderly structure of this nucleus make it a potentially better target to restore vision than the visual cortex. Existing research for the development of a thalamic visual prosthesis will be discussed along with the gaps that need to be addressed before such a technology could be applied clinically, as well as the challenge posed by the loss of LGN neurons as glaucoma progresses.


Subject(s)
Glaucoma/therapy , Thalamus/physiology , Vision, Ocular/physiology , Visual Prosthesis , Electric Stimulation , Geniculate Bodies/physiology , Glaucoma/physiopathology , Humans
14.
J Mech Behav Biomed Mater ; 49: 321-31, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26072197

ABSTRACT

This study aimed to investigate the structural, physical and mechanical behavior of composites and functionally graded materials (FGMs) made of stainless steel (SS-316L)/hydroxyapatite (HA) and SS-316L/calcium silicate (CS) employing powder metallurgical solid state sintering. The structural analysis using X-ray diffraction showed that the sintering at high temperature led to the reaction between compounds of the SS-316L and HA, while SS-316L and CS remained intact during the sintering process in composites of SS-316L/CS. A dimensional expansion was found in the composites made of 40 and 50 wt% HA. The minimum shrinkage was emerged in 50 wt% CS composite, while the maximum shrinkage was revealed in samples with pure SS-316L, HA and CS. Compressive mechanical properties of SS-316L/HA decreased sharply with increasing of HA content up to 20 wt% and gradually with CS content up to 50 wt% for SS-316L/CS composites. The mechanical properties of the FGM of SS-316L/HA dropped with increase in temperature, while it was improved for the FGM of SS-316L/CS with temperature enhancement. It has been found that the FGMs emerged a better compressive mechanical properties compared to both the composite systems. Therefore, the SS-316L/CS composites and their FGMs have superior compressive mechanical properties to the SS-316L/HA composites and their FGMs and also the newly developed FGMs of SS-316L/CS with improved mechanical and enhanced gradation in physical and structural properties can potentially be utilized in the components with load-bearing application.


Subject(s)
Biocompatible Materials/chemistry , Calcium Compounds/chemistry , Durapatite/chemistry , Materials Testing , Mechanical Phenomena , Physical Phenomena , Silicates/chemistry , Stainless Steel/chemistry , Compressive Strength , Hardness , Surface Properties , Weight-Bearing
15.
Artif Organs ; 39(2): 156-64, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24841371

ABSTRACT

This study aimed to assess the performance of different longitudinal functionally graded femoral prostheses. This study was also designed to develop an appropriate prosthetic geometric design for longitudinal functionally graded materials. Three-dimensional models of the femur and prostheses were developed and analyzed. The elastic modulus of these prostheses in the sagittal plane was adjusted along a gradient direction from the distal end to the proximal end. Furthermore, these prostheses were composed of titanium alloy and hydroxyapatite. Results revealed that strain energy, interface stress, and developed stress in the femoral prosthesis and the bone were influenced by prosthetic geometry and gradient index. In all of the prostheses with different geometries, strain energy increased as gradient index increased. Interface stress and developed stress decreased. The minimum principal stress and the maximum principal stress of the bone slightly increased as gradient index increased. Hence, the combination of the femoral prosthetic geometry and functionally graded materials can be employed to decrease stress shielding. Such a combination can also be utilized to achieve equilibrium in terms of the stress applied on the implanted femur constituents; thus, the lifespan of total hip replacement can be prolonged.


Subject(s)
Femur/surgery , Hip Prosthesis , Computer Simulation , Elastic Modulus , Finite Element Analysis , Humans , Models, Biological , Prosthesis Design , Stress, Mechanical
16.
ScientificWorldJournal ; 2014: 807621, 2014.
Article in English | MEDLINE | ID: mdl-25302331

ABSTRACT

This study is focused on finite element analysis of a model comprising femur into which a femoral component of a total hip replacement was implanted. The considered prosthesis is fabricated from a functionally graded material (FGM) comprising a layer of a titanium alloy bonded to a layer of hydroxyapatite. The elastic modulus of the FGM was adjusted in the radial, longitudinal, and longitudinal-radial directions by altering the volume fraction gradient exponent. Four cases were studied, involving two different methods of anchoring the prosthesis to the spongy bone and two cases of applied loading. The results revealed that the FG prostheses provoked more SED to the bone. The FG prostheses carried less stress, while more stress was induced to the bone and cement. Meanwhile, less shear interface stress was stimulated to the prosthesis-bone interface in the noncemented FG prostheses. The cement-bone interface carried more stress compared to the prosthesis-cement interface. Stair climbing induced more harmful effects to the implanted femur components compared to the normal walking by causing more stress. Therefore, stress shielding, developed stresses, and interface stresses in the THR components could be adjusted through the controlling stiffness of the FG prosthesis by managing volume fraction gradient exponent.


Subject(s)
Bone Cements/chemistry , Finite Element Analysis , Hip Prosthesis , Models, Anatomic , Prosthesis Design/methods , Durapatite/chemistry , Elastic Modulus , Femur/surgery , Humans , Materials Testing , Prosthesis Design/instrumentation , Stress, Mechanical , Titanium/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...