1.
Phys Rev E ; 106(5-2): 055208, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36559450

ABSTRACT

We establish multicomponent 1+ injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density n_{e}, average electron energy 〈E_{e}〉, and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the n_{e}, 〈E_{e}〉 ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The 〈E_{e}〉 and n_{e} of a hydrogen discharge are found to be 600_{-300}^{+600}eV and 8_{-3}^{+8}×10^{11}cm^{-3}, respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on the order of 1 ms-10 ms.

2.
Rev Sci Instrum ; 93(4): 043501, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35489927

ABSTRACT

To ensure further progress in the development of electron cyclotron resonance ion sources (ECRISs), deeper understanding of the underlying physics is required. The electron energy distribution (EED), which is crucial for the performance of an ECRIS, still remains obscure. The present paper focuses on the details of a well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS. The method allows for better than 500 eV energy resolution over a range of electron energies from 4 keV to over 1 MeV. We present detailed explanation of the experimental procedure and the following data processing peculiarities with examples and discuss possible reasons of energetic electron losses from the magnetic trap, in particular the role of RF pitch angle scattering. Finally, an experimental method of approximating the confined EED based on the measurement of escaping electrons is described.

3.
Rev Sci Instrum ; 93(1): 013302, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-35104948

ABSTRACT

The performance of a minimum-B Electron Cyclotron Resonance Ion Source (ECRIS) is traditionally quantified by measuring the beam current and quality of the extracted ion beams of different charge state ions. The stability of the extracted ion beam currents has drawn more attention recently as the technology is pushing its limits toward higher ion charge states and beam intensities. The stability of the extracted beam is often compromised by plasma instabilities manifesting themselves as rapid oscillations of the beam currents in millisecond scale. This paper focuses on practical aspects of diagnostics techniques of the instabilities, showcases examples of instability-related diagnostics signals, and links them to the plasma physics of ECR ion sources. The reviewed techniques include time-resolved microwave emission diagnostics, bremsstrahlung measurements, direct measurement of electron and ion fluxes, measurement of the ion beam energy spread, and optical emission diagnostics. We list the advantages and disadvantages of each technique and outline the development needs of further diagnostics. Finally, we discuss the implications of the instabilities in both historical and forward-looking context of ECRIS development.

4.
Rev Sci Instrum ; 91(4): 043307, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32357713

ABSTRACT

The standard 1X ISIS negative Penning surface plasma source has reliably produced an H- beam for ISIS operations for 35 years. In order to meet the 60 mA, 2 ms, and 50 Hz beam current and duty cycle required for the front end test stand (Letchford et al., in Proceedings of IPAC2015, Richmond, VA, USA, 2015), a 2X scaled source has been developed [Faircloth et al., AIP Conf. Proc. 2052, 050004 (2018)]. The 2X source has a plasma chamber twice the linear dimensions of the 1X source. This paper investigates the comparison between different emission areas (plasma electrode aperture dimensions) for both the 1X and 2X sources. Slit and circular extraction schemes are studied. A 3D Child-Langmuir relationship is observed where the space charge limited current density depends on the aspect ratio of the extraction aperture.

5.
Rev Sci Instrum ; 91(2): 023303, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32113443

ABSTRACT

An innovative 18 GHz HIISI (Heavy Ion Ion Source Injector) room temperature Electron Cyclotron Resonance (ECR) ion source (ECRIS) has been designed and constructed at the Department of Physics, University of Jyväskylä (JYFL), for the nuclear physics program of the JYFL Accelerator Laboratory. The primary objective of HIISI is to increase the intensities of medium charge states (M/Q ≅ 5) by a factor of 10 in comparison with the JYFL 14 GHz ECRIS and to increase the maximum usable xenon charge state from 35+ to 44+ to serve the space electronics irradiation testing program. HIISI is equipped with a refrigerated permanent magnet hexapole and a noncylindrical plasma chamber to achieve very strong radial magnetic confinement with Brad = 1.42 T. The commissioning of HIISI began in Fall 2017, and in Spring 2019, it has met the main objectives. As an example, the intensity of the Xe27+ ion beam has improved from 20 µA to 230 µA. In addition, the beam intensity of the Xe44+ ion beam has exceeded the requirement set by the irradiation testing program. The performance of HIISI is comparable to superconducting ECR ion sources with the same maximum microwave frequency of 18 GHz and a total power of 3 kW. For example, Ar16+ and Xe30+ ion beam intensities of 130 µA and 106 µA, respectively, have been obtained with a total microwave power of 3 kW distributed between 18, 17.4, and 14.5 GHz frequencies. The ion beams have been extracted through an 8 mm plasma electrode aperture using 15-17 kV extraction voltage. The latest development work, extracted ion beam intensities, special features, and future prospects of HIISI are presented in this paper.

6.
Rev Sci Instrum ; 91(1): 013502, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-32012519

ABSTRACT

Further progress in the development of electron cyclotron resonance (ECR) ion sources (ECRISs) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of the EED in an unstable mode of plasma confinement, i.e., in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences between the EED escaping from stable and unstable plasmas. It was found that nonlinear phenomena alter the EED noticeably. The electron losses are enhanced in both unstable regimes, with two-frequency heating suppressing the instabilities. It has been shown earlier that two-frequency heating boosts the ECRIS performance presumably owing to the suppression of instabilities. We report the observed changes in EED introduced by the secondary frequency in different regimes, including an off-resonance condition, where the secondary frequency is lower than the minimum frequency satisfying the resonance condition for cold electrons at the magnetic field minimum. Finally, we suggest an experimental method of qualitative evaluation of the energy distribution of electrons confined in the magnetic trap using a method of measuring energy distribution of lost electrons during the plasma decay in pulsed operation of the ion source.

7.
Rev Sci Instrum ; 91(1): 013304, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-32012571

ABSTRACT

Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative results. The cumulative confinement time estimates vary from approximately 2 ms-60 ms with a clear dependence on the ion charge-to-mass ratio-higher charges having longer residence times. The long cumulative confinement times are proposed as a partial explanation to recently observed unexpectedly high ion temperatures. The results are relevant for rare ion beam (RIB) production as the confinement time and the lifetime of stable isotopes can be used for estimating the extracted RIB production efficiency.

8.
Rev Sci Instrum ; 91(1): 013318, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-32012583

ABSTRACT

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction voltage of the ion source is switched off, accompanied by two orders of magnitude decrease in Ar9+ optical emission intensity, suggesting that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions of normal ECRIS operation. The relative changes of the plasma optical emission and the ion beam current have been measured in CW and amplitude modulation operation mode of microwave injection. It is concluded that in the CW mode, the ion currents could be limited by diffusion transport and electrostatic confinement of the ions rather than beam formation in the extraction region and subsequent transport. The high resolution of the spectrometer allows determining the ion temperature by measuring the Doppler broadening of the emission lines and subtracting the wavelength dependent instrumental broadening. The measured ion temperatures in the JYFL 14 GHz ECRIS are between 5 and 28 eV, depending on the plasma species and charge state. Gas mixing is shown to be an effective method to decrease the ion temperature of high charge state argon ions from 20 eV in pure argon discharge to 5 eV when mixed with oxygen.

9.
Rev Sci Instrum ; 91(1): 013517, 2020 Jan 01.
Article in English | MEDLINE | ID: mdl-32012642

ABSTRACT

Negative hydrogen ion sources are used as injectors into accelerators and drive the neutral beam heating in ITER. Certain processes in low-temperature hydrogen plasmas are accompanied by the emission of vacuum ultraviolet (VUV) emission. Studying the VUV radiation, therefore, provides volumetric rates of plasma-chemical processes and plasma parameters. In the past, we have used gasdynamic ECR discharge for volumetric negative ion production and investigated the dependencies between the extracted H- current density and various ion source parameters. It was shown that it is possible to reach up to 80 mA/cm2 of negative ion current density with a two electrode extraction. We report experimental studies on negative hydrogen ion production in a high-density gasdynamic ECR discharge plasma consisting of two simple mirror traps together with the results of VUV emission measurements. The VUV-power was measured in three ranges-Lyα, Lyman band, and molecular continuum-varying the source control parameters near their optima for H- production. It was shown that the molecular continuum emission VUV power is the highest in the first chamber while Lyα emission prevails in the second one. Modifications for the experimental scheme for further optimization of negative hydrogen ion production are suggested.

10.
Rev Sci Instrum ; 90(11): 113321, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31779446

ABSTRACT

The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the plasma at high densities. Parallel to the technical development of the ion sources themselves, significant effort has been directed into the development of their plasma diagnostic tools. We review the recent results of Electron Cyclotron Resonance Ion Source (ECRIS) plasma diagnostics highlighting a number of selected examples of plasma density, electron energy distribution, and ion confinement time measurements, obtained mostly with the second-generation sources operating at frequencies from 10 to 18 GHz. The development of minimum-B ECR ion sources based on the superposition of solenoid and sextupole fields has long relied on semiempirical scaling laws for the strength of the magnetic field with increasing plasma heating frequency. This approach is becoming increasingly difficult with the looming limits of superconducting technologies being able to satisfy the magnetic field requirements at frequencies approaching 60 GHz. Thus, we discuss alternative ECRIS concepts and proposed modifications to existing sources that are supported by the current understanding derived from the plasma diagnostics experiments.

11.
Rev Sci Instrum ; 90(12): 123303, 2019 Dec 01.
Article in English | MEDLINE | ID: mdl-31893842

ABSTRACT

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas are prone to kinetic instabilities resulting in loss of electron and ion confinement. It is demonstrated that the biased disk of an ECRIS can be used as a probe to quantify such instability-induced electron and ion losses occurring in less than 10 µs. The qualitative interpretation of the data is supported by the measurement of the energy spread of the extracted ion beams implying a transient plasma potential >1.5 kV during the instability. A parametric study of the electron losses combined with electron tracking simulations allows for estimating the fraction of electrons expelled in each instability event to be on the order of 10% of the total electron population.

12.
Phys Rev Lett ; 120(15): 155001, 2018 Apr 13.
Article in English | MEDLINE | ID: mdl-29756884

ABSTRACT

We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic radiation into the continuous-wave regime of a cyclotron maser formed in magnetically confined nonequilibrium plasma. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in a MHD-stable minimum-B open magnetic trap.

13.
Rev Sci Instrum ; 89(4): 043506, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29716347

ABSTRACT

The results of optical emission spectroscopy experiments probing the cold electron population of a 14 GHz Electron Cyclotron Resonance Ion Source (ECRIS) are reported. The study has been conducted with a high resolution spectrometer and data acquisition setup developed specifically for the diagnostics of weak emission line characteristic to ECRIS plasmas. The optical emission lines of low charge state ions and neutral atoms of neon have been measured and analyzed with the line-ratio method. The aforementioned electron population temperature of the cold electron population (Te < 100 eV) is determined for Maxwell-Boltzmann and Druyvesteyn energy distributions to demonstrate the applicability of the method. The temperature was found to change significantly when the extraction voltage of the ion source is turned on/off. In the case of the Maxwellian distribution, the temperature of the cold electron population is 20 ± 10 eV when the extraction voltage is off and 40 ± 10 eV when it is on. The optical emission measurements revealed that the extraction voltage also affects both neutral and ion densities. Based on the rate coefficient analysis with the aforementioned temperatures, switching the extraction voltage off decreases the rate coefficient of neutral to 1+ ionization to 42% and 1+ to 2+ ionization to 24% of the original. This suggests that switching the extraction voltage on favors ionization to charge states ≥2+ and, thus, the charge state distributions of ECRIS plasmas are probably different with the extraction voltage on/off. It is therefore concluded that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions in normal ECRIS operation.

14.
Rev Sci Instrum ; 87(9): 093301, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27782615

ABSTRACT

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O3+-O7+ were recorded at various tuner positions and frequencies in the range of 14.00-14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited "mode-hopping" between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

15.
Rev Sci Instrum ; 87(2): 02A701, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931919

ABSTRACT

The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz A-electron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10-100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime.

16.
Rev Sci Instrum ; 87(2): 02A703, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931921

ABSTRACT

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of ECRISs.

17.
Rev Sci Instrum ; 87(2): 02A704, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931922

ABSTRACT

An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H(+), H2(+), and H3(+) ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical factor for transitions between different plasma patterns and ion populations.

18.
Rev Sci Instrum ; 87(2): 02A715, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931933

ABSTRACT

A new type of ECR ion source-a gasdynamic ECR ion source-has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600-700 emA/cm(2) in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for plasma heating in a magnetic trap with simple mirror configuration. Initial studies of plasma parameters were performed. Ion beams with pulsed and CW high voltage were successfully extracted from the CW discharge. Obtained experimental results demonstrate that all advantages of the gasdynamic source can be realized also in CW operation.

19.
Rev Sci Instrum ; 87(2): 02A716, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931934

ABSTRACT

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)-the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller's ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10(13) cm(-3)) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10(-4)-10(-3) mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

20.
Rev Sci Instrum ; 87(2): 02A725, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931943

ABSTRACT

Several ion source related research and development projects are in progress at the Department of Physics, University of Jyväskylä (JYFL). The work can be divided into investigation of the ion source plasma and development of ion sources, ion beams, and diagnostics. The investigation covers the Electron Cyclotron Resonance Ion Source (ECRIS) plasma instabilities, vacuum ultraviolet (VUV) and visible light emission, photon induced electron emission, and the development of plasma diagnostics. The ion source development covers the work performed for radiofrequency-driven negative ion source, RADIS, beam line upgrade of the JYFL 14 GHz ECRIS, and the development of a new room-temperature-magnet 18 GHz ECRIS, HIISI.