Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Akush Ginekol (Sofiia) ; 41(1): 20-4, 2001.
Article in Bulgarian | MEDLINE | ID: mdl-11519303

ABSTRACT

The authors present a modern review on the early oral intake after cesarean section and gynecological operations and their own experience with 130 cesarean and 100 gynecological operated women. This is for the first time on our (Bulgarian) practice. Early oral intake was well tolerated by the patients, there were no more postoperative complications associated with the new method of postoperative care. The authors recommended this approach for the clinical practice.


Subject(s)
Cesarean Section , Eating , Gynecologic Surgical Procedures , Postoperative Care/methods , Enteral Nutrition , Female , Humans , Patient Satisfaction , Pregnancy , Time Factors
2.
Akush Ginekol (Sofiia) ; 39(1): 10-3, 2000.
Article in Bulgarian | MEDLINE | ID: mdl-10826327

ABSTRACT

The authors make a review on this problem for first time in Bulgarian literature and for the first time by us operated with the Misgav Ladach method--cesarean section. The authors describe 50 cases wit Ladach method and as control 20 with Pfannenstiel. The authors establish shorter duration of the operation-Si] and 56.3 min. respective in benefit for Misgav method; the babies were extracted at 5.5 and 12.3 min. respect. The mothers with Misgav had better prognosis at the time of dehospitalization.


Subject(s)
Cesarean Section/methods , Gynecologic Surgical Procedures/methods , Laparotomy/methods , Cesarean Section/statistics & numerical data , Female , Gynecologic Surgical Procedures/statistics & numerical data , Humans , Laparotomy/statistics & numerical data , Pregnancy
3.
Akush Ginekol (Sofiia) ; 30(2): 18-20, 1991.
Article in Bulgarian | MEDLINE | ID: mdl-1909100

ABSTRACT

The authors describe indications for usage of venous administrations by means of the infusion pump IP 2-50 in newborns, pregnant women and parturients as well as during feeding of the smallest preterm infants with the same pump. Advantages and disadvantages of IP 2-50 are presented in comparison with the perfusion pumps "Braun Melsungen" and "Lineomat". Nosologic units are described, in which infusions with IP 2-50 are applied.


Subject(s)
Infant, Premature, Diseases/therapy , Infusion Pumps , Pregnancy Complications/therapy , Puerperal Disorders/therapy , Evaluation Studies as Topic , Female , Humans , Infant, Newborn , Infant, Premature , Parenteral Nutrition/instrumentation , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL
...