Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 148
Filter
1.
Ophthalmol Retina ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38750936

ABSTRACT

PURPOSE: To report a previously undescribed finding of peripapillary hyperreflective ovoid mass-like structures (PHOMS) in Stickler syndrome. DESIGN: Noncomparative case series. SUBJECTS: Twenty-two eyes with anomalous optic disc from 11 Stickler syndrome patients were identified and imaged. METHODS: Peripapillary hyperreflective ovoid mass-like structures were graded using enhanced-depth imaging OCT (EDI-OCT) according to the consensus recommendations of the Optic Disc Drusen Studies Consortium. All EDI-OCT scans were obtained using the Heidelberg Spectralis (Heidelberg Engineering) with a dense horizontal raster (15 × 10°, 97 sections) centered on the optic nerve head and graded by 2 independent assessors. In case of disagreement, the image was graded by a third assessor. The presence of any coexisting optic disc drusen was also assessed using EDI-OCT and autofluorescence. MAIN OUTCOME MEASURES: The presence of PHOMS, clinical characteristics and genetic mutations. RESULTS: A pilot sample of 22 eyes with phenotypic optic disc abnormalities from 11 Stickler syndrome patients were identified and imaged. Eight patients were female and 3 were male. The mean age was 31 years (13-58 years). Peripapillary hyperreflective ovoid mass-like structures were present in 91% (n = 20) of imaged eyes. Seventy percent (n = 14) were type 1 Stickler syndrome and 30% (n = 6) were type 2 Stickler syndrome. All eyes were myopic and the degree of myopia did not seem to affect whether or not PHOMS was present in this cohort. One eye with PHOMS had retinal detachment, and 77.3% (n = 17) of eyes had undergone 360o prophylactic retinopexy. Thirty-two percent (n = 7) of eyes with PHOMS were present in patients with coexisting hearing loss and 22.7% (n = 5) had orofacial manifestation of Stickler syndrome in the form of a cleft palate. Seventy-seven percent (n = 15) of eyes with PHOMS were present in patients who reported joint laxity or symptoms of arthritis. No coexisting optic disc drusen were identified and raised intracranial pressure was also excluded after neurological investigation. CONCLUSIONS: These data suggest that PHOMS are a novel finding in Stickler syndrome patients and should be considered when evaluating the optic nerves of these patients. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Echocardiography ; 41(3): e15799, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38516862

ABSTRACT

Atherosclerosis is the most common cause of heart disease and stroke. Plaque thickness ≥4 mm in the ascending aorta or aortic arch is strongly correlated with cerebral embolic events and ischemic stroke. However, despite imaging workup, the cause of embolic stroke remains unidentified in many patients. Transesophageal echocardiography (TEE) is the preferred echocardiographic method for the evaluation of cardiac source of emboli. 2D TEE imaging evaluates aortic root and aortic arch in a single plane or two planes with biplane imaging. However, 2D TEE often fails to detect mobile or complex components in the ascending aorta and aortic arch plaques. The routine availability of 3D TEE in current ultrasound systems may significantly improve the assessment of aortic plaques as a potential embolic source. In this case series, we present four consecutive patients with stroke who underwent TEE by a single cardiologist for possible cardioembolic source. Some of these patients may have been labelled as "cryptogenic stroke" or "embolic stroke of undetermined source" (ESUS) due to the presence of insignificant or nonmobile ascending aortic or aortic arch plaques on 2D TEE imaging. In our four consecutive patients with ESUS who underwent TEE by a single operator, 3D TEE showed complex aortic arch plaques with ulceration with mobile components and established these plaques as the likely source of embolic stroke.


Subject(s)
Aortic Diseases , Atherosclerosis , Embolic Stroke , Embolism , Plaque, Atherosclerotic , Stroke , Humans , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/diagnostic imaging , Echocardiography, Transesophageal/methods , Embolic Stroke/complications , Atherosclerosis/complications , Atherosclerosis/diagnostic imaging , Stroke/complications , Stroke/diagnostic imaging , Aorta, Thoracic/diagnostic imaging , Embolism/complications , Aortic Diseases/complications , Aortic Diseases/diagnostic imaging
3.
BMC Med ; 22(1): 88, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38419017

ABSTRACT

BACKGROUND: The risk of incident atrial fibrillation (AF) among breast cancer survivors, especially for younger women, and cancer treatment effects on the association remain unclear. This study aimed to investigate the risk of AF among breast cancer survivors and evaluate the association by age group, length of follow-up, and cancer treatment. METHODS: Using data from the Korean Health Insurance Service database (2010-2017), 113,232 women newly diagnosed with breast cancer (aged ≥ 18 years) without prior AF history who underwent breast cancer surgery were individually matched 1:5 by birth year to a sample female population without cancer (n = 566,160) (mean[SD] follow-up, 5.1[2.1] years). Sub-distribution hazard ratios (sHRs) and 95% confidence intervals (CIs) considering death as a competing risk were estimated, adjusting for sociodemographic factors and cardiovascular/non-cardiovascular comorbidities. RESULTS: BCS had a slightly increased AF risk compared to their cancer-free counterparts (sHR 1.06; 95% CI 1.00-1.13), but the association disappeared over time. Younger BCS (age < 40 years) had more than a 2-fold increase in AF risk (sHR 2.79; 95% CI 1.98-3.94), with the association remaining similar over 5 years of follow-up. The increased risk was not observed among older BCS, especially those aged > 65 years. Use of anthracyclines was associated with increased AF risk among BCS (sHR 1.57; 95% CI 1.28-1.92), which was more robust in younger BCS (sHR 1.94; 95% CI 1.40-2.69 in those aged ≤ 50 years). CONCLUSIONS: Our findings suggest that younger BCS had an elevated risk of incident AF, regardless of the length of follow-up. Use of anthracyclines may be associated with increased mid-to-long-term AF risk among BCS.


Subject(s)
Atrial Fibrillation , Breast Neoplasms , Cancer Survivors , Humans , Female , Atrial Fibrillation/epidemiology , Atrial Fibrillation/diagnosis , Breast Neoplasms/epidemiology , Breast Neoplasms/surgery , Survivors , Anthracyclines , Risk Factors , Incidence
4.
J Clin Med ; 13(2)2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38256445

ABSTRACT

OBJECTIVES: The performed hand-held echocardiography (HHE) was evaluated and interpreted by trained advanced practice providers (APPs) on hospitalized CHF patients for image quality and interpretation by comparing with expert echocardiographer and SE findings. BACKGROUND: Congestive heart failure (CHF) is associated with increased hospital admissions and mortality. While a standard echocardiogram (SE) is the gold standard for cardiac assessment, it is not readily available. Hospitalized CHF patients require rapid assessment for expedited treatment. METHODS: Over 6 months, five trained APPs performed HHE on hospitalized CHF patients and interpreted: (a) left ventricular (LV) size, (b) LV ejection fraction (LVEF), and (c) right atrial pressure (RAP). The study echocardiographer reviewed and blindly interpreted the HHE images and compared them with APPs and SE findings. Kappa statistics determined the degree of agreement between APPs and the study echocardiographer's interpretation of the HHE images and SE. RESULTS: A total of 80 CHF patients (age 73 ± 14 years, 58% males; LVEF (by SE) 45 ± 19%; 36.3% body mass indexes ≥ 30 kg/m2) were enrolled. HHE interpretation by APPs had a good agreement for LVEF (kappa 0.79) with the study echocardiographer and SE (kappa 0.74) and a good agreement for RAP (kappa 0.67) with the study echocardiographer. The correlation between the absolute LVEF interpretation by the study echocardiographer on HHE and SE was r = 0.88 (p < 0.0001). CONCLUSIONS: Trained APPs obtained diagnostic-quality HHE images and interpreted the LV function and RAP in CHF patients in good agreement with the study echocardiographer. LVEF by HHE correlated with LVEF by SE. Our study suggests trained APPs can use HHE to evaluate LVEF and RAP in CHF patients, leading to expedited and optimized treatment.

6.
J Am Soc Echocardiogr ; 37(4): 420-427, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38036012

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) can reliably detect left atrial (LA) and LA appendage (LAA) thrombus in patients with atrial fibrillation (AF) before electrical cardioversion (ECV). However, evaluating cardiac and valve function pre-ECV can be challenging due to the increased and irregular heart rate. Additionally, post-ECV atrial stunning increases the risk of LAA thrombosis. Therefore, post-ECV TEE may allow for useful appendage, ventricular, and valve function assessment. However, the safety and usefulness of leaving the TEE probe in situ during ECV for post-ECV cardiac evaluation in clinical practice have not been previously evaluated. METHODS: We analyzed 37 out of 86 consecutive patients who had the TEE probe left in situ, for clinical reasons, during ECV by a single operator between February 20, 2019, and January 3, 2023. We examined changes in left ventricular (LV) function, dynamic changes in valvular regurgitation, electromechanical coupling of the left atrium, and qualitative spontaneous echo contrast. We also assessed the presence of any complications related to the periprocedural TEE exam. RESULTS: The mean age of the patients was 74 ± 9.65 years, and 29 (78%) were male. The periprocedural TEE time ranged from 7 to 55 minutes, with an average of 20.78 minutes. Immediately after ECV and restoration of normal sinus rhythm, there was an improvement in LV ejection fraction (47% ± 11.9% vs 40% ± 15.8%; P = .035). There was also a reduction in baseline mitral regurgitation of greater than moderate degree. However, spontaneous echo contrast worsened in the LAA in 11 (31.4%) patients. Additionally, 1 patient developed a new LAA thrombus, and 24 patients (72%) had evidence of electromechanical coupling with Doppler evidence of LA contraction. Clinically significant degenerative aortic and mitral stenosis were identified in 8% and mild or greater aortic regurgitation in 8% of patients post-ECV. No procedural complications were observed. CONCLUSIONS: In situ TEE before, during, and after ECV is safe and provides useful clinical information regarding immediate cardiac changes after ECV, with diagnostic and therapeutic implications.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Thrombosis , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Echocardiography, Transesophageal , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Electric Countershock , Echocardiography , Atrial Appendage/diagnostic imaging
7.
J Imaging ; 9(11)2023 Nov 15.
Article in English | MEDLINE | ID: mdl-37998097

ABSTRACT

Aortic valve stenosis (AS) is increasing in prevalence due to the aging population, and severe AS is associated with significant morbidity and mortality. Echocardiography remains the mainstay for the initial detection and diagnosis of AS, as well as for grading of severity. However, there are important subgroups of patients, for example, patients with low-flow low-gradient or paradoxical low-gradient AS, where quantification of severity of AS is challenging by echocardiography and underestimation of severity may delay appropriate management and impart a worse prognosis. Aortic valve calcium score by computed tomography has emerged as a useful clinical diagnostic test that is complimentary to echocardiography, particularly in cases where there may be conflicting data or clinical uncertainty about the degree of AS. In these situations, aortic valve calcium scoring may help re-stratify grading of severity and, therefore, further direct clinical management. This review presents the evolution of aortic valve calcium score by computed tomography, its diagnostic and prognostic value, as well as its utility in clinical care.

8.
Mayo Clin Proc ; 98(10): 1501-1514, 2023 10.
Article in English | MEDLINE | ID: mdl-37793726

ABSTRACT

OBJECTIVE: To study the usefulness of a novel echocardiographic marker, augmented mean arterial pressure (AugMAP = [(mean aortic valve gradient + systolic blood pressure) + (2 × diastolic blood pressure)] / 3), in identifying high-risk patients with moderate aortic stenosis (AS). PATIENTS AND METHODS: Adults with moderate AS (aortic valve area, 1.0-1.5 cm2) at Mayo Clinic sites from January 1, 2010, through December 31, 2020, were identified. Baseline demographic, echocardiographic, and all-cause mortality data were retrieved. Patients were grouped into higher and lower AugMAP groups using a cutoff value of 80 mm Hg for analysis. Kaplan-Meier and Cox regression models were used to assess the performance of AugMAP. RESULTS: A total of 4563 patients with moderate AS were included (mean ± SD age, 73.7±12.5 years; 60.5% men). Median follow-up was 2.5 years; 36.0% of patients died. The mean ± SD left ventricular ejection fraction (LVEF) was 60.1%±11.4%, and the mean ± SD AugMAP was 99.1±13.1 mm Hg. Patients in the lower AugMAP group, with either preserved or reduced LVEF, had significantly worse survival performance (all P<.001). Multivariate Cox regression showed that AugMAP (hazard ratio, 0.962; 95% CI, 0.942 to 0.981 per 5-mm Hg increase; P<.001) and AugMAP less than 80 mm Hg (hazard ratio, 1.477; 95% CI, 1.241 to 1.756; P<.001) were independently associated with all-cause mortality. CONCLUSION: AugMAP is a simple and effective echocardiographic marker to identify high-risk patients with moderate AS independent of LVEF. It can potentially be used in the candidate selection process if moderate AS becomes indicated for aortic valve intervention in the future.


Subject(s)
Aortic Valve Stenosis , Ventricular Function, Left , Male , Adult , Humans , Middle Aged , Aged , Aged, 80 and over , Female , Stroke Volume/physiology , Ventricular Function, Left/physiology , Arterial Pressure , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Severity of Illness Index , Treatment Outcome
9.
J Clin Med ; 12(20)2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37892613

ABSTRACT

BACKGROUND: Early diagnosis of significant valvular heart disease (VHD) enables appropriate implementation of the best therapeutic strategy and follow-up. Cardiac auscultation remains suboptimal in early detection of VHD. The aim of this study was to evaluate the utility of point-of-care ultrasound (POCUS) for early detection of VHD and its severity. METHODS: All consecutive patients with VHD who did not have a standard echocardiogram prior to first outpatient cardiology consultation underwent history and physical examination followed by POCUS study by an experienced physician in a general cardiology clinic from June 2017 to August 2022 at our institution. Subsequent standard transthoracic echocardiography (sTTE) was performed as the gold standard. Comparison was performed between POCUS and sTTE for the presence and severity of VHD. sTTE was performed by registered cardiac sonographers and interpreted by another cardiologist blinded to the POCUS results. RESULTS: A total of 77 patients were studied (ge 72 ± 11 years, 58.4% males). A total of 89 significant valvular abnormalities were diagnosed. There were 39 (43.8%) cases of regurgitant VHD, 16 (18.0%) of stenotic VHD and 34 (38.2%) had evaluation for prosthetic valve function. The sensitivity (90.9%; 82.4%; 83.3%; 100%) and specificity (100%; 96.7%; 100%; 100%) were high for detecting ≥ moderate aortic regurgitation (AR), mitral regurgitation (MR), aortic stenosis (AS) and prosthetic valvular abnormality, respectively. The weighted κ coefficient between POCUS and sTTE for the assessment of ≥ moderate MR, AR and AS was 0.81 (95% CI, 0.65-0.97), 0.94 (95% CI, 0.84-1.00) and 0.88 (95% CI, 0.76-1.0), respectively, indicating excellent agreement. CONCLUSIONS: POCUS can identify patients with significant VHD and may serve as a powerful screening tool for early detection of significant VHD in the outpatient clinical practice with downstream impact on clinical management of significant VHD.

10.
J Clin Med ; 12(17)2023 Aug 31.
Article in English | MEDLINE | ID: mdl-37685731

ABSTRACT

Cardiac structural and valve interventions have remained surgical procedures for several decades. The ability to directly visualize the region of interest during surgery made imaging of these structures pre- and postsurgery a secondary tool to compliment surgical visualization. The last two decades, however, have seen rapid advances in catheter-based percutaneous structural heart interventions (SHIs). Due to the "blind" nature of these interventions, imaging plays a crucial role in the success of these procedures. Fluoroscopy is used universally in all percutaneous cardiac SHIs and helps primarily in the visualization of catheters and devices. However, success of these procedures requires visualization of intracardiac soft tissue structures. Due to its portable nature and rapid ability to show cardiac structures online, transesophageal echocardiography (TEE) has become an integral tool for guidance for all percutaneous SHI. Transcatheter aortic valve replacement-one of the earliest catheter-based procedures-while initially dependent on TEE, has largely been replaced by preprocedural cardiac CT for accurate assessment of valve sizing. Developments in echocardiography now allow live three-dimensional (3D) visualization of cardiac structures mimicking surgical anatomy during TEE. Besides showing actual 3D intracardiac structures, 3D-TEE allows visualization of the interaction of intracardiac catheters and devices with soft tissue cardiac structures, thereby becoming a "second pair of eyes" for the operator. Real-time 3D-TEE now plays an important role complementing multiplane two dimensional and biplane TEE during such interventions. In this review, we discuss the incremental role of 3D-TEE during various SHIs performed today.

11.
J Cardiovasc Dev Dis ; 10(5)2023 Apr 26.
Article in English | MEDLINE | ID: mdl-37233159

ABSTRACT

BACKGROUND: Post-transcatheter aortic valve replacement (TAVR) patient outcome is an important research topic. To accurately assess post-TAVR mortality, we examined a family of new echo parameters (augmented systolic blood pressure (AugSBP) and arterial mean pressure (AugMAP)) derived from blood pressure and aortic valve gradients. METHODS: Patients in the Mayo Clinic National Cardiovascular Diseases Registry-TAVR database who underwent TAVR between 1 January 2012 and 30 June 2017 were identified to retrieve baseline clinical, echocardiographic and mortality data. AugSBP, AugMAP and valvulo-arterial impedance (Zva) (Zva) were evaluated using Cox regression. Receiver operating characteristic curve analysis and the c-index were used to assess the model performance against the Society of Thoracic Surgeons (STS) risk score. RESULTS: The final cohort contained 974 patients with a mean age of 81.4 ± 8.3 years old, and 56.6% were male. The mean STS risk score was 8.2 ± 5.2. The median follow-up duration was 354 days, and the one-year all-cause mortality rate was 14.2%. Both univariate and multivariate Cox regression showed that AugSBP and AugMAP parameters were independent predictors for intermediate-term post-TAVR mortality (all p < 0.0001). AugMAP1 < 102.5 mmHg was associated with a 3-fold-increased risk of all-cause mortality 1-year post-TAVR (hazard ratio 3.0, 95%confidence interval 2.0-4.5, p < 0.0001). A univariate model of AugMAP1 surpassed the STS score model in predicting intermediate-term post-TAVR mortality (area under the curve: 0.700 vs. 0.587, p = 0.005; c-index: 0.681 vs. 0.585, p = 0.001). CONCLUSIONS: Augmented mean arterial pressure provides clinicians with a simple but effective approach to quickly identify patients at risk and potentially improve post-TAVR prognosis.

12.
Echocardiography ; 40(6): 475-482, 2023 06.
Article in English | MEDLINE | ID: mdl-37151118

ABSTRACT

BACKGROUND: Goal directed point of care ultrasound (POCUS) is a bedside tool to assist with clinical diagnosis. We examined the impact of POCUS performed by consulting cardiologist (CC) during initial cardiology consult on clinical management and downstream testing. METHODS: Sixty-nine study patients (pts) seen in a general cardiology outpatient clinic of a tertiary center by an expert imaging CC were compared to a control group of 65 pts seen by three different CCs without POCUS during the same time-period, in whom the first standard echo (SE) was performed after the initial visit. RESULTS: Baseline characteristics were similar between the two groups for age, cardiac risk factors, and referral diagnoses. Echo findings on POCUS and by SE (mean delay of 17.2 days after visit) in the control group were comparable for RV size and function and for valvular heart disease. More patients with lower LVEF, higher LV filling pressures, new regional wall motion abnormalities, and increased aortic root size were present among POCUS group resulting in greater yield of echo abnormalities. There were more cardiovascular medication changes at the first visit (15.3% vs. 5.7%, p < .01), less referral for noninvasive stress testing (10% vs. 29%, p < .01), more advanced cardiac testing and subspecialty referrals (29% vs. 18% pts, p = .06), in the study compared to the control group after cardiology visit. CONCLUSION: POCUS at time of consultation detects more abnormal echo findings, results in more medication adjustments, less referral for noninvasive stress testing, earlier referral for advanced cardiac diagnostic imaging, and subspecialty cardiac referrals.


Subject(s)
Cardiology , Physicians , Humans , Point-of-Care Systems , Outpatients , Ultrasonography/methods , Referral and Consultation
13.
Heliyon ; 9(2): e13359, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36825188

ABSTRACT

With the advent of Industry 4.0, several cutting-edge technologies such as cyber-physical systems, digital twins, IoT, robots, big data, cloud computation have emerged. However, how these technologies are interconnected or fused for collaborative and increased functionality is what elevates 4.0 to a grand scale. Among these fusions, the digital twin (DT) in robotics is relatively new but has unrivaled possibilities. In order to move forward with DT-integrated robotics research, a complete evaluation of the literature and the creation of a framework are now required. Given the importance of this research, the paper seeks to explore the trends of DT incorporated robotics in both high and low research saturated robotic domains in order to discover the gap, rising and dying trends, potential scopes, challenges, and viable solutions. Finally, considering the findings, the study proposes a framework based on a hypothesis for the future paradigm of DT incorporated robotics.

14.
Echocardiography ; 40(3): 266-270, 2023 03.
Article in English | MEDLINE | ID: mdl-36597407

ABSTRACT

We present a case of a 60-year-old male who was found to be in atrial fibrillation during routine evaluation. Anticoagulation was initiated for 36 h and he was referred for TEE-guided electrical cardioversion. There was no thrombus identified in the left atrial appendage, however, the appendage was large and had a tongue-like accessory lobe along with spontaneous contrast in the left atrium and its appendage. TEE probe was not withdrawn, patient underwent successful cardioversion with 200 joules and developed a marked increase in left atrial and left atrial appendage spontaneous contrast along with the development of tear drop shaped thrombus in the left atrial appendage immediately after cardioversion, which rapidly became more dense. There was an associated marked decrease in appendage velocities. Patient was hospitalized to initiate low molecular weight heparin. This case highlights the need for vigilance in patients with an unknown duration of atrial fibrillation, who have received a short duration of anticoagulant therapy and who have adverse appendage anatomy as thrombus may develop immediately after cardioversion despite anticoagulation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Thrombosis , Male , Humans , Middle Aged , Echocardiography, Transesophageal , Electric Countershock , Anticoagulants , Thrombosis/etiology , Atrial Appendage/diagnostic imaging
15.
Trends Cardiovasc Med ; 33(2): 109-122, 2023 02.
Article in English | MEDLINE | ID: mdl-34742888

ABSTRACT

Right ventricular (RV) pacing is the main treatment modality for patients with advanced atrioventricular (AV) block. Chronic RV pacing can cause cardiac systolic dysfunction and heart failure (HF). In this review, we discuss studies that have shown deleterious effects of chronic RV pacing on systolic cardiac function causing pacing-induced cardiomyopathy (PiCM), heart failure (HF), HF hospitalization, atrial fibrillation (AF) and cardiac mortality. RV apical pacing is the most widely used and studied. Adverse effects of RV pacing appear to be directly related to pacing burden and are worse in patients with pre-existing left ventricular (LV) dysfunction. Chronic RV pacing is also associated with heart failure with preserved ejection fraction (HFpEF). Mechanisms, risk factors, clinical and echocardiographic features, and strategies to minimize RV pacing-induced cardiac dysfunction are discussed in light of the latest data. Studies on biventricular (Bi-V) pacing upgrade in patients who develop RV PiCM, use of alternate RV pacing sites, de novo Bi-V pacing, and physiologic pacing using HIS bundle pacing (HBP) and left bundle area (LBBA) pacing in patients with an anticipated high RV pacing burden are discussed.


Subject(s)
Atrioventricular Block , Cardiac Resynchronization Therapy , Cardiomyopathies , Heart Failure , Ventricular Dysfunction, Left , Humans , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/prevention & control , Prevalence , Stroke Volume , Atrioventricular Block/therapy , Cardiac Resynchronization Therapy/adverse effects , Cardiac Pacing, Artificial/adverse effects
16.
J Echocardiogr ; 21(1): 45-47, 2023 03.
Article in English | MEDLINE | ID: mdl-34350556
17.
J Neurosurg Spine ; 38(4): 494-502, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36585871

ABSTRACT

OBJECTIVE: Clinical care pathways designed to triage spinal disorders have been shown to reduce wait times and improve patient satisfaction. The goal of this study was to perform an analysis of outpatient radiology costs before and after the implementation of a spine care triage pathway. METHODS: All imaging orders and surgical procedures were captured in a prospective spine registry for patients referred to the department of neurosurgery within a single academic center between July 1, 2017, and November 3, 2020. A spine triage algorithm was developed and implemented January 1, 2018. Healthcare utilization was recorded for 1 year after the first appointment in the department of neurosurgery. Imaging costs were estimated using publicly available data from the Centers for Medicare and Medicaid Services. Statistical analysis consisted of an independent sample t-test or randomization test for continuous variables and a chi-square test for categorical variables. RESULTS: A total of 3854 patients were included in this study. The mean age was 60 years (50.8% female) and 89.8% had undergone advanced imaging before being referred to the department of neurosurgery. In total, 12.6% of patients were referred with a specific surgical diagnosis (i.e., spinal stenosis, lumbar spondylolisthesis, etc.). During the pretriage phase 1810 patients were enrolled, and there were 2044 patients enrolled after the triage algorithm was implemented. Advanced imaging (CT or MRI) was ordered more frequently by providers before the triage program was initiated, with imaging ordered in 34% (617/1810) of patients pretriage versus 14.8% (302/2044) after the triage pathway was implemented (p < 0.001). The authors calculated a significant reduction in cost associated with reduced radiology utilization. Before triage, the cost of radiology utilization was $85,475/1000 patients compared with $40,107/1000 patients afterward (p < 0.001). The triage program did not change the utilization of surgery (14.6% before, 13.6% after). CONCLUSIONS: Among patients treated after a spinal triage program was implemented in a single neurosurgery department, there was a substantial reduction in the use of advanced imaging and a 50% reduction in cost associated with outpatient radiology utilization. The triage program did not change the rate of spine surgery being performed.


Subject(s)
Outpatients , Radiology , Humans , Female , Aged , United States , Middle Aged , Male , Prospective Studies , Triage , Medicare
18.
JACC Adv ; 2(10): 100700, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38938485
20.
Eye (Lond) ; 36(3): 555-563, 2022 03.
Article in English | MEDLINE | ID: mdl-33746209

ABSTRACT

BACKGROUND: A variety of shared care models have been developed, which aim to stratify glaucoma patients according to risk of disease progression. However, there is limited published data on the rate of glaucoma progression in the hospital vs community setting. Here we aimed to compare rates of glaucomatous visual field progression in the Cambridge Community Optometrist Glaucoma Scheme (COGS) and Addenbrooke's Hospital Glaucoma Clinic (AGC). METHODS: A retrospective comparative cohort review was performed. Patients with five or more visual field tests were included. Zeiss Forum software was used to calculate the MD progression rate (dB/year). Loss of sight years (LSY) were also calculated for both COGS and AGC. RESULTS: Overall, 8465 visual field tests from 854 patients were reviewed. In all, 362 eyes from the AGC group and 210 eyes from COGS were included. The MD deterioration rate was significantly lower in the COGS patients compared with the AGC group (-0.1 vs -0.3 dB/year; p < 0.0001). No patients in the COGS group were predicted to become blind within their lifetime by LSY analysis. Fifteen patients were at risk in the AGC group. CONCLUSION: This service evaluation shows that COGS is an effective scheme to stratify lower risk glaucoma patients, increasing the capacity within hospital eye services. COGS patients have a lower rate of visual field deterioration compared to AGC patients. Effective communication between community and tertiary schemes is essential to facilitate transfer of patients requiring further hospital management reliably and efficiently, with the potential for low-risk patients to be followed safely in the community.


Subject(s)
Glaucoma , Visual Fields , Disease Progression , Glaucoma/diagnosis , Glaucoma/therapy , Hospitals , Humans , Intraocular Pressure , Retrospective Studies , Vision Disorders/diagnosis , Vision Disorders/epidemiology , Visual Field Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...