Eur Phys J Plus ; 138(6): 495, 2023.
Article in English | MEDLINE | ID: mdl-37304246

ABSTRACT

MAX IV Laboratory is a Swedish national synchrotron radiation facility that comprises three accelerators with varying characteristics. One of the accelerators, the 3 GeV storage ring, is the world's first fourth-generation ring and pioneered the use of the multibend achromat lattice to provide access to ultrahigh brightness X-rays. MAX IV aims to stay at the forefront of the current and future research needs of its multidisciplinary user community, principally located in the Nordic and Baltic regions. Our 16 beamlines currently offer and continue to develop modern X-ray spectroscopy, scattering, diffraction, and imaging techniques to address scientific problems of importance to society.

2.
J Synchrotron Radiat ; 29(Pt 2): 462-469, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35254310

ABSTRACT

A wiggler is a high-power insertion device that was used in the past to produce a smooth wide-band X-ray spectrum. It is widely believed that on low-emittance synchrotrons this X-ray source loses its spatial and spectral homogeneity and therefore becomes less ideal than a scanning undulator. In this paper, we report on experimental and computational studies of an in-vacuum wiggler installed on the first fourth-generation synchrotron MAX IV. We investigate how several physical parameters affect the wiggler spectrum and propose a combination of a few of them that results in significant spectral smoothing. We also examine EXAFS spectra for possible distortions originating from the source imperfection. For this purpose, we scrutinize samples of various homogeneity. We conclude that wigglers are still an appropriate class of insertion devices, also on low-emittance synchrotrons.

3.
J Synchrotron Radiat ; 21(Pt 5): 878-83, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25177979

ABSTRACT

Some of the characteristics of recent ultralow-emittance storage-ring designs and possibly future diffraction-limited storage rings are a compact lattice combined with small magnet apertures. Such requirements present a challenge for the design and performance of the vacuum system. The vacuum system should provide the required vacuum pressure for machine operation and be able to handle the heat load from synchrotron radiation. Small magnet apertures result in the conductance of the chamber being low, and lumped pumps are ineffective. One way to provide the required vacuum level is by distributed pumping, which can be realised by the use of a non-evaporable getter (NEG) coating of the chamber walls. It may not be possible to use crotch absorbers to absorb the heat from the synchrotron radiation because an antechamber is difficult to realise with such a compact lattice. To solve this, the chamber walls can work as distributed absorbers if they are made of a material with good thermal conductivity, and distributed cooling is used at the location where the synchrotron radiation hits the wall. The vacuum system of the 3 GeV storage ring of MAX IV is used as an example of possible solutions for vacuum technologies for diffraction-limited storage rings.