Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Oral Implantol (Berl) ; 17(2): 175-185, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801331

ABSTRACT

PURPOSE: The reverse guided bone regeneration protocol is a digital workflow that has been introduced to reduce the complexity of guided bone regeneration and promote prosthetically guided bone reconstruction with a view to achieving optimal implant placement and prosthetic finalisation. The aim of the present study was to investigate the accuracy of this digital protocol. MATERIALS AND METHODS: Sixteen patients with partial edentulism in the maxilla or mandible and with vertical or horizontal bone defects were treated using the reverse guided bone regeneration protocol to achieve fixed implant rehabilitations. For each patient, a digital wax-up of the future rehabilitation was created and implant planning was carried out, then the necessary bone reconstruction was simulated virtually and the CAD/CAM titanium mesh was designed and used to perform guided bone regeneration. The computed tomography datasets from before and after guided bone regeneration were converted into 3D models and aligned digitally. The actual position of the mesh was compared to the virtual position to assess the accuracy of the digital project. Surgical and healing complications were also recorded. A descriptive analysis was conducted and a one-sample t test and Wilcoxon test were utilised to assess the statistical significance of the accuracy. The level of significance was set at 0.05. RESULTS: A total of 16 patients with 16 treated sites were enrolled. Comparing the virtually planned mesh position with the actual position, an overall mean discrepancy between the two of 0.487 ± 0.218 mm was achieved. No statistically significant difference was observed when comparing this to a predefined minimum tolerance (P = 0.06). No surgical complications occurred, but two healing complications were recorded (12.5%). CONCLUSION: Within the limitations of the present study, the reverse guided bone regeneration digital protocol seems to be able to achieve good accuracy in reproducing the content of the virtual plan. Nevertheless, further clinical comparative studies are required to confirm these results.


Subject(s)
Bone Regeneration , Computer-Aided Design , Surgical Mesh , Titanium , Humans , Female , Male , Middle Aged , Aged , Adult , Tomography, X-Ray Computed/methods , Jaw, Edentulous, Partially/surgery , Jaw, Edentulous, Partially/rehabilitation , Dental Implantation, Endosseous/methods , Treatment Outcome , Imaging, Three-Dimensional/methods , Guided Tissue Regeneration, Periodontal/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...