Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Res ; 95(3): 584-601, 1983 Sep.
Article in English | MEDLINE | ID: mdl-6611863

ABSTRACT

Groups of C57BL/Do (black and albino) mice were injected with graded activities of 226Ra, 239Pu, 241Am, 249Cf, or 252Cf and were followed throughout life. Bone sarcoma was the principal radiation-induced end point, and the risks associated with average skeletal doses of the four transuranium radionuclides, relative to radium, were determined. The relative biological effectiveness (RBE) was calculated for each emitter by dividing its risk coefficient (bone sarcomas per 10(6) mouse-rad) by the risk coefficient for 226Ra. Combined data for males and females in both black and albino mice gave the following values +/- SD for the RBE relative to 226Ra = 1.0: 239Pu = 15.3 +/- 3.9, 241Am = 4.9 +/- 1.4, 249Cf = 5.0 +/- 1.4, and 252Cf = 2.6 +/- 0.8. About 70% of the tumors occurred in the axial skeleton, and the risk coefficient for females averaged about four times higher than for males when all five nuclides were included. The RBE of fission fragment irradiation from 252Cf for cancer induction, relative to alpha irradiation, for the combined data in all of the animals given 252Cf and 249Cf, was 0.02 +/- 0.28, in agreement with the calculated theoretical value of 0.03, based on the ratio of summed track lengths in tissue.


Subject(s)
Americium/toxicity , Californium/toxicity , Plutonium/toxicity , Radium/toxicity , Alpha Particles , Animals , Bone Neoplasms/etiology , Dose-Response Relationship, Radiation , Female , Injections, Intravenous , Male , Mice , Mice, Inbred C57BL , Models, Biological , Neoplasms, Radiation-Induced/etiology , Radioactivity , Risk , Sarcoma, Experimental/etiology , Sex Factors
2.
Radiat Environ Biophys ; 16(2): 157-75, 1979 Apr 30.
Article in English | MEDLINE | ID: mdl-112640

ABSTRACT

A human total-body counter was designed and built with two 20 X 10 cm NaI (Tl) crystals suspended over an "isoresponse surface" upon which the subject reclines. This surface is curved from head to knee and from left to right, so that a gamma-ray emitting object is detected with equal efficiency when placed anywhere upon it. The positioner and detectors are housed in a low background enclosure constructed of steel 31 cm thick with a graded inner lining of lead + cadmium + copper. Calibration of the system was accomplished by administering trace amounts of various radionuclides to 48 human subjects of various sizes, ranging in age from 4--80 years. Counting rates per retained muCi at 0.53, 0.66, 1.53, and 2.75 MeV (83Rb, 137Cs, 42K, and 24Na) were determined as a function of body size and were compared with counting rates per muCi of corresponding emitters centered in a polyethylene cylinder of radius 10.3 cm. Limits of detection, corresponding to three times the standard deviation of a 50 min background, were 170 nCi 90Sr (via Bremsstrahlung X-rays), 0.78 nCi 131I, 0.48 nCi 83Rb, 0.52 nCi 137 Cs, 4.9 nCi 40K (or 5.8 g of natural potassium) and 1.7 nCi 222Rn.


Subject(s)
Radioisotopes , Spectrometry, Gamma/instrumentation , Whole-Body Counting/instrumentation , Body Height , Body Weight , Female , Humans , Male , Models, Structural
SELECTION OF CITATIONS
SEARCH DETAIL
...