Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
In Vivo ; 33(3): 689-698, 2019.
Article in English | MEDLINE | ID: mdl-31028185

ABSTRACT

BACKGROUND/AIM: To evaluate the effect of an ultrasonic cleaning and disinfection method for CAD/CAM abutment surfaces on cell viability and inflammatory response in vitro. MATERIALS AND METHODS: Untreated and manually polished surfaces of CAD/CAM generated titanium and zirconia disks were randomly assigned, either to a 3-step ultrasonic cleaning and disinfection process (test: TiUF, TiPF, ZrUF, ZrPF) or to 30 sec steam cleaning (control: TiUS, TiPS, ZrUS, ZrPS). Pre-cleaning surface analyses using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and surface profilometry were performed. Human gingival fibroblasts (HGFs) were cultured on test and control specimens and subsequently examined for cell viability and inflammatory response. Expression of acute inflammatory cytokine interleukin (IL)-6 and vascular endothelial growth factor A (VEGFA) were assessed by means of RT-qPCR. RESULTS: Cells on all specimens exhibited a satisfactory viability, indicating firm attachment. Cells on polished zirconia samples, cleaned by means of sonication (ZrPF), exhibited significantly higher viability than cells on the same material cleaned by steam (ZrPS), p=0.019. For all other three material/ surface treatment combinations (TiU, TiP, ZrU), no such difference was observed between the cleaning methods. The messenger ribonucleic acid (mRNA) levels of IL-6 and VEGFA were between 50 and 105% of that of the control cells on the non-toxic control surface. mRNA levels of IL-6 and VEGFA correlated well with each other. CONCLUSION: Except for higher viability of cells cultured on polished zirconia specimens, no universally applicable advantage could be found for the ultrasonic cleaning procedure for zirconia and titanium abutment surfaces regarding cell viability, IL-6 expression or VEGFA expression. The cleaning procedures did not have any negative effect either.


Subject(s)
Cell Survival , Computer-Aided Design , Disinfection/methods , Sonication , Biomarkers , Cell Culture Techniques , Disinfection/instrumentation , Fibroblasts , Gene Expression , Humans , Sonication/instrumentation , Sonication/methods , Surface Properties
2.
J Adv Prosthodont ; 10(3): 197-204, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29930789

ABSTRACT

PURPOSE: To determine the extent of treatment traces, the roughness depth, and the quantity of titanium nitride (TiN) removed from the surface of CAD/CAM abutments after treatment with various instruments. MATERIALS AND METHODS: Twelve TiN coated CAD/CAM abutments were investigated for an in vitro study. In the test group (9), each abutment surface was subjected twice (150 g vs. 200 g pressure) to standardized treatment in a simulated prophylaxis measure with the following instruments: acrylic scaler, titanium curette, and ultrasonic scaler with steel tip. Three abutments were used as control group. Average surface roughness (Sa) and developed interfacial area ratio (Sdr) of treated and untreated surfaces were measured with a profilometer. The extent of treatment traces were analyzed by scanning electron microscopy. RESULTS: Manipulation with ultrasonic scalers resulted in a significant increase of average surface roughness (Sa, P<.05) and developed interfacial area ratio (Sdr, P<.018). Variable contact pressure did not yield any statistically significant difference on Sa-values for all instruments (P=.8). Ultrasonic treatment resulted in pronounced surface traces and partially detachment of the TiN coating. While titanium curettes caused predominantly moderate treatment traces, no traces or detectable substance removal has been determined after manipulation with acrylic curettes. CONCLUSION: Inappropriate instruments during regular plaque control may have an adverse effect on the integrity of the TiN coating of CAD/CAM abutments. To prevent defects and an increased surface roughness at the transmucosal zone of TiN abutments, only acrylic scaling instruments can be recommended for regular maintenance care.

3.
Int J Prosthodont ; 30(6): 553­555, 2017.
Article in English | MEDLINE | ID: mdl-29084300

ABSTRACT

PURPOSE: This study evaluated the retention strength of welding caps for Ankylos standard abutments using a pull-out test. MATERIALS AND METHODS: Each sample consisted of an implant abutment and its welding cap. The tests were performed with a Zwick Roell testing machine with a 1-kN load cell. RESULTS: The retention strength of the welding caps increased with higher abutment diameters and higher head heights and was comparable or superior to the values reported in the literature for the temporary cements used in implant dentistry. CONCLUSION: Welding caps provide a reliable connection between an abutment and a fixed prosthesis without the use of cement.


Subject(s)
Dental Abutments , Dental Prosthesis Retention , Dental Prosthesis, Implant-Supported , Mechanical Phenomena
4.
Proc Inst Mech Eng H ; 231(9): 839-850, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28554262

ABSTRACT

Fatigue behavior of the titanium bars is of utmost importance for the safe and reliable operation of dental implants and prosthetic constructions based on these implants. To date, however, only few data are available on the fatigue strength of dental prostheses made with electric resistance welding and laser welding techniques. This in-vitro study highlighted that although the joints made with the laser welding approach are credited of a superior tensile strength, joints made with electric resistance welding exhibited double the minimum fatigue strength with respect to the joints made with laser welding (120 vs 60 N).


Subject(s)
Hardness Tests , Lasers , Stress, Mechanical , Titanium , Welding , Dental Prosthesis , Electric Impedance , Surface Properties , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...