Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 129(13): 132501, 2022 Sep 23.
Article in English | MEDLINE | ID: mdl-36206412

ABSTRACT

Nuclear charge radii of ^{55,56}Ni were measured by collinear laser spectroscopy. The obtained information completes the behavior of the charge radii at the shell closure of the doubly magic nucleus ^{56}Ni. The trend of charge radii across the shell closures in calcium and nickel is surprisingly similar despite the fact that the ^{56}Ni core is supposed to be much softer than the ^{48}Ca core. The very low magnetic moment µ(^{55}Ni)=-1.108(20) µ_{N} indicates the impact of M1 excitations between spin-orbit partners across the N,Z=28 shell gaps. Our charge-radii results are compared to ab initio and nuclear density functional theory calculations, showing good agreement within theoretical uncertainties.

2.
Opt Express ; 25(2): 1123-1130, 2017 Jan 23.
Article in English | MEDLINE | ID: mdl-28157997

ABSTRACT

A continuously tunable titanium:sapphire (Ti:Sa) laser self-seeded by an extended grating cavity was demonstrated and characterized. By inserting a partially reflecting mirror inside the cavity of a classic single-cavity grating laser, two oscillators are created: a broadband power oscillator and a narrowband oscillator with a prism beam expander and a diffraction grating in Littrow configuration. By coupling the grating cavity oscillation into the power oscillator, a power-enhanced narrow-linewidth laser oscillation is achieved. Compared to the classic grating laser, this simple modification significantly increases the laser output power without considerably broadening the linewidth. With most of the oscillating laser power confined inside the broadband power cavity and lower power incident onto the grating, the new configuration also allows higher pump power, which is typically limited by the thermal deformation of the grating coating at high oscillation power.

3.
Rev Sci Instrum ; 85(5): 053305, 2014 May.
Article in English | MEDLINE | ID: mdl-24880362

ABSTRACT

A new decay station has been built for the ISAC facility at TRIUMF for the rapid and reliable characterization of radioactive ion beam (RIB) compositions and intensities with the capability of simultaneously collecting α, ß, and γ decay data from RIB with intensities between a few and ≈10(11) ions per second. It features user-friendly control, data acquisition, and analysis software. The analysis of individual decay time structures allows the unambiguous assignment of α and γ lines even with substantial isobaric contamination present. The capability for accurate half-life measurements is demonstrated with the example of (46)K. The coupling of the yield station to the laser ion source, TRILIS, allows the correlation of radiometric data with automated laser frequency scans. First results of in-source laser spectroscopy measurements on astatine are discussed.

4.
Rev Sci Instrum ; 85(3): 033309, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24689577

ABSTRACT

Modern experiments at isotope separator on-line (ISOL) facilities like ISAC at TRIUMF often depend critically on the purity of the delivered rare isotope beams. Therefore, highly selective ion sources are essential. This article presents the development and successful on-line operation of an ion guide laser ion source (IG-LIS) for the production of ion beams free of isobaric contamination. Thermionic ions from the hot ISOL target are suppressed by an electrostatic potential barrier, while neutral radio nuclides effusing out are resonantly ionized by laser radiation within a quadrupole ion guide behind this barrier. The IG-LIS was developed through detailed thermal and ion optics simulation studies and off-line tests with stable isotopes. In a first on-line run with a SiC target a suppression of surface-ionized Na contaminants in the ion beam of up to six orders of magnitude was demonstrated.

SELECTION OF CITATIONS
SEARCH DETAIL
...