1.
Int J Oral Maxillofac Surg ; 43(10): 1269-75, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24794761

ABSTRACT

This study investigated the effect of undersized preparations with two different implant macrogeometries. There were four experimental groups: group 1, conical implant with an undersized osteotomy of 3.2mm; group 2, conical implant with an undersized osteotomy of 3.5mm; group 3, cylindrical implant with an undersized osteotomy of 3.2mm; group 4, cylindrical implant with an undersized osteotomy of 3.5mm. Implants were placed in one side of the sheep mandible (n=6). After 3 weeks, the same procedure was conducted on the other side; 3 weeks later, euthanasia was performed. All implants were 4mm×10mm. Insertion torque was recorded for all implants during implantation. Retrieved samples were subjected to histological sectioning and histomorphometry. Implants of groups 1 and 2 presented significantly higher insertion torque than those of groups 3 and 4 (P<0.001). No differences in bone-to-implant contact or bone area fraction occupied were observed between the groups at 3 weeks (P>0.24, and P>0.25, respectively), whereas significant differences were observed at 6 weeks between groups 1 and 2, and between groups 3 and 4 (P<0.01). Undersized drilling affected the biological establishment of bone formation around both dental implant macrogeometries.


Subject(s)
Dental Implantation, Endosseous/methods , Dental Implants , Mandible/surgery , Animals , Dental Prosthesis Design , Implants, Experimental , Osseointegration , Osteotomy , Sheep , Surface Properties , Torque
2.
Int J Oral Maxillofac Surg ; 43(7): 883-8, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24583140

ABSTRACT

Information concerning the effects of the implant cutting flute design on initial stability and its influence on osseointegration in vivo is limited. This study evaluated the early effects of implants with a specific cutting flute design placed in the sheep mandible. Forty-eight dental implants with two different macro-geometries (24 with a specific cutting flute design - Blossom group; 24 with a self-tapping design - DT group) were inserted into the mandibular bodies of six sheep; the maximum insertion torque was recorded. Samples were retrieved and processed for histomorphometric analysis after 3 and 6 weeks. The mean insertion torque was lower for Blossom implants (P<0.001). No differences in histomorphometric results were observed between the groups. At 3 weeks, P=0.58 for bone-to-implant contact (BIC) and P=0.52 for bone area fraction occupied (BAFO); at 6 weeks, P=0.55 for BIC and P=0.45 for BAFO. While no histomorphometric differences were observed, ground sections showed different healing patterns between the implants, with better peri-implant bone organization around those with the specific cutting flute design (Blossom group). Implants with the modified cutting flute design had a significantly reduced insertion torque compared to the DT implants with a traditional cutting thread, and resulted in a different healing pattern.


Subject(s)
Dental Implantation, Endosseous/methods , Dental Implants , Dental Prosthesis Design , Osseointegration/physiology , Animals , Dental Stress Analysis , Mandible/surgery , Models, Animal , Sheep , Torque , Wound Healing/physiology
3.
Rev. AMRIGS ; 27(4): 482-7, 1983.
Article in Portuguese | LILACS | ID: lil-18273

ABSTRACT

Um caso de carcinoma de mama em jovem de 18 anos e relatado. Uma revisao bibliografica revelou apenas tres outros casos descritos, ocorrendo no sexo masculino e em idade igual ou inferior a esta


Subject(s)
Adolescent , Humans , Male , Breast Neoplasms