Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Turk J Ophthalmol ; 49(1): 6-9, 2019 02 28.
Article in English | MEDLINE | ID: mdl-30829018

ABSTRACT

Objectives: It is important to determine variables that influence intraocular pressure (IOP) measurement. This study aimed to evaluate the effect of body position on IOP. Materials and Methods: The study included 52 right eyes of 52 patients who presented to the ophthalmology department of our hospital and had no ocular disease except refractive errors. IOP was measured with an Icare PRO tonometer while patients were in sitting, standing, and supine positions, with intervals of 10 minutes between the positions. Correlations between the results were evaluated using Spearman's correlation analysis and Wilcoxon tests. Results: Thirty-six of the 52 patients were female, 16 were male. Mean age was 31.65±6.30 (23-47) years. Mean IOP values in the sitting, standing, and lying positions were 17.76±3.41 (12.70-25.60) mmHg, 17.10±3.27 (11.50-25.20) mmHg, and 18.46±4.67 (10.50-29.40) mmHg, respectively. There were no statistically significant differences between measurements taken in the different positions (p=0.112, p=0.472, p=0.071). We observed that there was no relationship between age and body position (p>0.45, p>0.79, p>0.77) or between gender and position (p>0.59, p>0.69, p>0.54). Conclusion: Gender and age had no effect on IOP measured in different body positions. There were also no significant differences between IOP values measured in the different positions. Therefore, we believe the portable Icare PRO tonometer can be used for patients who are confined to bed and will provide IOP measurements that are concordant with values obtained while sitting.


Subject(s)
Glaucoma/diagnosis , Intraocular Pressure/physiology , Posture/physiology , Tonometry, Ocular/methods , Adult , Age Factors , Female , Humans , Male , Middle Aged , Sex Factors , Young Adult
2.
Turk J Anaesthesiol Reanim ; 44(2): 81-5, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27366563

ABSTRACT

OBJECTIVE: We compared the effects of the laryngeal mask airway (LMA), face mask and Cobra perilaryngeal airway (PLA) in the airway management of spontaneously breathing paediatric patients undergoing elective inguinal surgery. METHODS: In this study, 90 cases of 1-14-year-old children undergoing elective inguinal surgery were scheduled. The patients were randomly divided into three groups. Anaesthesia was provided with sevoflurane and 50%-50% nitrous oxide and oxygen. After providing an adequate depth of anaesthesia, supraglottic airway devices were inserted in the group I and II patients. The duration and number of insertion, haemodynamic parameters, plateau and peak inspiratory pressure and positive end-expiratory pressure of the patients were recorded preoperatively, after induction and at 5, 10, 15 and 30 min peroperatively. RESULTS: There were no statistical differences between the groups in terms of haemodynamic parameters (p>0.05). In group II, instrumentation success was higher and instrumentation time was shorter than group II. The positive end-expiratory pressure and plateau and peak inspiratory pressure values were statistically lower in group II (p<0.05). CONCLUSION: We concluded that for airway safety and to avoid possible complications, LMA and Cobra PLA could be alternatives to face mask and that the Cobra PLA provided lower airway pressure and had a faster and more easy placement than LMA.

SELECTION OF CITATIONS
SEARCH DETAIL
...