Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Int Angiol ; 41(3): 196-204, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35138072

ABSTRACT

BACKGROUND: Postimplantation syndrome (PIS) represents an acute phase systemic inflammatory response following endovascular aortic aneurysm repair (EVAR). Our objective was to investigate the risk factors associated with the manifestation and severity of PIS with various available stent-grafts. METHODS: We performed a retrospective analysis of prospectively collected data covering the period 2016-2020. The study included 191 patients. Body temperature was recorded regularly and blood sample was obtained daily. The imaging protocol included computed tomography aortoiliac angiography before surgery and one month after. The volumes of pre-existing and new-onset mural thrombus were calculated in a semi-automated fashion. Five abdominal aortic stent-graft devices were used: Endurant™ ΙΙ, Anaconda™, Treo®, E-tegra® and AFX® 2. Subgroup analysis was performed between woven polyester and ePTFE lined devices. RESULTS: The incidence of PIS was 21.5%. No significant differences were observed regarding demographics, risk factors, aneurysm anatomy or operative data. The amount of pre-existing and new-onset mural thrombus were not related with PIS (P=0.117 and P=0.096). PIS incidence in the polyester subgroup was 24.2%, significantly higher compared to 8.3% in the ePTFE subgroup. In-subgroup analysis revealed that the use of Anaconda™ was associated with the higher frequency (61.1%, P=0.021). Multivariate logistic regression showed that polyester was the single factor significantly associated with PIS (hazard ratio=2.6, P=0.043), as opposed to the new onset thrombus (hazard ratio=1.29, P=0.101). CONCLUSIONS: PIS is not uncommon and should be taken into consideration in patients presenting with fever after EVAR. The endograft's liner material seems to play the primordial role, with woven polyester to be attributed with significantly higher incidence.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Thrombosis , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Incidence , Polyesters , Retrospective Studies , Risk Factors , Stents/adverse effects , Syndrome , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...