Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Forensic Sci Int Genet ; 19: 56-67, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26122263

ABSTRACT

There is increasing interest in forensic ancestry tests, which are part of a growing number of DNA analyses that can enhance routine profiling by obtaining additional genetic information about unidentified DNA donors. Nearly all ancestry tests use single nucleotide polymorphisms (SNPs), but these currently rely on SNaPshot single base extension chemistry that can fail to detect mixed DNA. Insertion-deletion polymorphism (Indel) tests have been developed using dye-labeled primers that allow direct capillary electrophoresis detection of PCR products (PCR-to-CE). PCR-to-CE maintains the direct relationship between input DNA and signal strength as each marker is detected with a single dye, so mixed DNA is more reliably detected. We report the results of a collaborative inter-laboratory exercise of 19 participants (15 from the EDNAP European DNA Profiling group) that assessed a 34-plex SNP test using SNaPshot and a 46-plex Indel test using PCR-to-CE. Laboratories were asked to type five samples with different ancestries and detect an additional mixed DNA sample. Statistical inference of ancestry was made by participants using the Snipper online Bayes analysis portal plus an optional PCA module that analyzes the genotype data alongside calculation of Bayes likelihood ratios. Exercise results indicated consistent genotyping performance from both tests, reaching a particularly high level of reliability for the Indel test. SNP genotyping gave 93.5% concordance (compared to the organizing laboratory's data) that rose to 97.3% excluding one laboratory with a large number of miscalled genotypes. Indel genotyping gave a higher concordance rate of 99.8% and a reduced no-call rate compared to SNP analysis. All participants detected the mixture from their Indel peak height data and successfully assigned the correct ancestry to the other samples using Snipper, with the exception of one laboratory with SNP miscalls that incorrectly assigned ancestry of two samples and did not obtain informative likelihood ratios for a third. Therefore, successful ancestry assignments were achieved by participants in 92 of 95 Snipper analyses. This exercise demonstrates that ancestry inference tests based on binary marker sets can be readily adopted by laboratories that already have well-established CE regimes in place. The Indel test proved to be easy to use and allowed all exercise participants to detect the DNA mixture as well as achieving complete and concordant profiles in nearly all cases. Lastly, two participants successfully ran parallel next-generation sequencing analyses (each using different systems) and achieved high levels of genotyping concordance using the exercise PCR primer mixes unmodified.


Subject(s)
Electrophoresis, Capillary/methods , Forensic Genetics , Genetic Markers , DNA/genetics , Genotype , Humans , Polymorphism, Single Nucleotide
2.
J Arthroplasty ; 16(8 Suppl 1): 195-202, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11742475

ABSTRACT

The current study evaluates the 4- to 8-year results of 26 cemented femoral revisions with impaction allografting using a collared femoral component in cases of extensive femoral bone loss. Patients were followed prospectively and were evaluated at an average of 6.0 years after the allograft revision procedure. The average age at the time of surgery was 69.3 years. At final follow-up, 20 patients (20 hips) were living, and 6 patients (6 hips) were deceased. No femoral component rerevisions were performed for any reason in any patient, and none were radiographically loose at final follow-up. There was 1 subsided femoral component of <5 mm, 3 postoperative periprosthetic femoral fractures, and a greater trochanter nonunion rate of 32%. At the current follow-up interval, these cemented femoral revisions with impaction allografting have performed well with excellent clinical and radiographic durability in this difficult patient population. The prevalence of periprosthetic fracture is a significant concern. This study shows durable results using the impaction allografting technique in cases of severe bone loss.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Transplantation/methods , Femur/pathology , Hip Prosthesis , Aged , Aged, 80 and over , Cementation , Female , Femur/surgery , Follow-Up Studies , Hip Joint/diagnostic imaging , Hip Joint/surgery , Humans , Male , Middle Aged , Prosthesis Failure , Radiography , Reoperation , Transplantation, Homologous , Treatment Outcome
3.
J Bone Joint Surg Am ; 83(11): 1706-11, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11701795

ABSTRACT

BACKGROUND: Although cementless acetabular components are routinely used in revision hip surgery, few investigators have evaluated the retention and efficacy of these components in the long term. In the current study, the clinical and radiographic outcomes of a series of arthroplasties performed by one surgeon with a cementless acetabular component were assessed at a minimum of ten years. METHODS: From 1986 through 1988, sixty-one consecutive revision total hip arthroplasties were performed in fifty-five patients because of aseptic failure of one or both components of a prosthesis in which both components had been cemented. Twenty-eight patients (thirty-two hips) were alive at a mean of 12.9 years (range, 11.5 to 14.3 years) after the operation. In all of the patients, the acetabular component was revised to a porous-coated Harris-Galante component inserted without cement, and the femoral component was revised to an Iowa component affixed with contemporary cementing techniques. The hips were evaluated clinically and radiographically at a minimum of ten years subsequent to the index revision. No hips were lost to follow-up. RESULTS: None of the acetabular components required revision because of aseptic loosening. Two hips (3%) demonstrated radiographic evidence of aseptic loosening of the acetabular component. The polyethylene liner was exchanged during the follow-up period in eight hips. CONCLUSION: After a minimum of ten years of follow-up, cementless acetabular fixation in revision hip arthroplasty had produced durable results that were markedly better than those reported for acetabular fixation with cement.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Adult , Aged , Arthroplasty, Replacement, Hip/instrumentation , Cementation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Failure , Reoperation , Statistics, Nonparametric , Survival Analysis , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...