Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Ann Acad Med Singap ; 53(3): 170-186, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38920244

ABSTRACT

Introduction: Tuberculosis (TB) remains endemic in Singapore. Singapore's clinical practice guidelines for the management of tuberculosis were first published in 2016. Since then, there have been major new advances in the clinical management of TB, ranging from diagnostics to new drugs and treatment regimens. The National TB Programme convened a multidisciplinary panel to update guidelines for the clinical management of drug-susceptible TB infection and disease in Singapore, contextualising current evidence for local practice. Method: Following the ADAPTE framework, the panel systematically reviewed, scored and synthesised English-language national and international TB clinical guidelines published from 2016, adapting recommendations for a prioritised list of clinical decisions. For questions related to more recent advances, an additional primary literature review was conducted via a targeted search approach. A 2-round modified Delphi process was implemented to achieve consensus for each recommendation, with a final round of edits after consultation with external stakeholders. Results: Recommendations for 25 clinical questions spanning screening, diagnosis, selection of drug regimen, monitoring and follow-up of TB infection and disease were formulated. The availability of results from recent clinical trials led to the inclusion of shorter treatment regimens for TB infection and disease, as well as consensus positions on the role of newer technologies, such as computer-aided detection-artificial intelligence products for radiological screening of TB disease, next-generation sequencing for drug-susceptibility testing, and video observation of treatment. Conclusion: The panel updated recommendations on the management of drug-susceptible TB infection and disease in Singapore.


Subject(s)
Antitubercular Agents , Delphi Technique , Tuberculosis, Pulmonary , Tuberculosis , Humans , Singapore , Antitubercular Agents/therapeutic use , Tuberculosis, Pulmonary/drug therapy , Tuberculosis, Pulmonary/diagnosis , Tuberculosis/drug therapy , Tuberculosis/diagnosis , Consensus
2.
Kidney Int Rep ; 8(9): 1741-1751, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37705910

ABSTRACT

Introduction: Vitamin K deficiency among patients on hemodialysis (HD) affects the function of matrix GLA protein (MGP), a potent vitamin K-dependent inhibitor of vascular calcification (VC). Methods: We conducted a single-center randomized controlled trial (RCT) on maintenance HD patients to examine if vitamin K2 supplementation can reduce progression of coronary artery calcification (CAC) over an 18-month study period. Patients were randomized to vitamin K2 group receiving menaquinone-7360 µg 3 times/wk or control group. The primary outcome was CAC scores at the end of the study period. The secondary outcomes were aortic valve calcification (AVC), carotid-femoral pulse wave velocity (cfPWV), aortic augmentation index (AIx), dephosphorylated undercarboxylated MGP (dp-ucMGP) levels, major adverse cardiac events (MACE), and vascular access events. Results: Of the 178 patients randomized, follow-up was completed for 138 patients. The CAC scores between the 2 groups were not statistically different at the end of 18 months (relative mean difference [RMD] 0.85, 95% CI 0.55-1.31). The secondary outcomes did not differ significantly in AVC (RMD 0.82, 95% CI 0.34-1.98), cfPWV (absolute mean difference [AMD] 0.55, 95% CI -0.50 to 1.60), and AIx (AMD 0.13, 95% CI -3.55 to 3.80). Supplementation with vitamin K2 did reduce dp-ucMGP levels (AMD -86, 95% CI -854 to -117). The composite outcome of MACE and mortality was not statistically different between the 2 groups (Hazard ratio = 0.98, 95% CI 0.50-1.94). Conclusion: Our study did not demonstrate a beneficial effect of vitamin K2 in reducing progression of VC in this population at the studied dose and duration.

3.
Drug Saf ; 46(10): 927-949, 2023 10.
Article in English | MEDLINE | ID: mdl-37552439

ABSTRACT

Trastuzumab deruxtecan (T-DXd)-an antibody-drug conjugate targeting the human epidermal growth factor receptor 2 (HER2)-improved outcomes of patients with HER2-positive and HER2-low metastatic breast cancer. Guidance on monitoring and managing T-DXd-related adverse events (AEs) is an emerging unmet need as translating clinical trial experience into real-world practice may be difficult due to practical and cultural considerations and differences in health care infrastructure. Thus, 13 experts including oncologists, pulmonologists and a radiologist from the Asia-Pacific region gathered to provide recommendations for T-DXd-related AE monitoring and management by using the latest evidence from the DESTINY-Breast trials, our own clinical trial experience and loco-regional health care considerations. While subgroup analysis of Asian (excluding Japanese) versus overall population in the DESTINY-Breast03 uncovered no major differences in the AE profile, we concluded that proactive monitoring and management are essential in maximising the benefits with T-DXd. As interstitial lung disease (ILD)/pneumonitis is a serious AE, patients should undergo regular computed tomography scans, but the frequency may have to account for the median time of ILD/pneumonitis onset and access. Trastuzumab deruxtecan appears to be a highly emetic regimen, and prophylaxis with serotonin receptor antagonists and dexamethasone (with or without neurokinin-1 receptor antagonist) should be considered. Health care professionals should be vigilant for treatable causes of fatigue, and patients should be encouraged to use support groups and practice low-intensity exercises. To increase treatment acceptance, patients should be made aware of alopecia risk prior to starting T-DXd. Detailed monitoring and management recommendations for T-DXd-related AEs are discussed further.


Subject(s)
Immunoconjugates , Lung Diseases, Interstitial , Pneumonia , Humans , Asia
4.
Radiol Cardiothorac Imaging ; 5(6): e230064, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38166346

ABSTRACT

Purpose To develop a new coronary CT angiography (CCTA)-based index, α×LL/MLD4, that considers lesion entrance angle (α) in addition to lesion length (LL) and minimal lumen diameter (MLD) and to evaluate its efficacy in predicting hemodynamically significant coronary stenosis compared with invasive coronary angiography (ICA)-derived fractional flow reserve (FFR). Materials and Methods This prospective study enrolled participants (September 2016-March 2020) from two centers who underwent CCTA followed by ICA (ClinicalTrials.gov identifier: NCT03054324). CCTA images were processed semiautomatically to measure LL, MLD, and α for calculating α×LL/MLD4. Diagnostic performance and accuracy of α×LL/MLD4 and LL/MLD4 in detecting hemodynamically significant coronary stenosis were compared against the reference standard (invasive FFR ≤ 0.80). Results In total, 133 participants (mean age, 63 years ± 9 [SD]; 99 [74%] men) with 210 stenosed coronary arteries were analyzed. Median α×LL/MLD4 was 54.0 degree/mm3 (IQR, 25.3-128.7) in participants with invasive FFR of 0.80 or less and 6.7 degree/mm3 (IQR, 3.3-12.8) in participants with invasive FFR of more than 0.80 (P < .001). The per-vessel accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for discriminating ischemic lesions were 86.2%, 83.1%, 88.4%, 84.1%, and 87.7% for α×LL/MLD4 and 80.5%, 66.3%, 90.9%, 84.3%, and 78.6% for LL/MLD4, respectively. Area under the receiver operating characteristic curve for discriminating hemodynamically significant stenosis was 0.93 for α×LL/MLD4, which was significantly greater than the values of 0.84 for LL/MLD4 and 0.63 for diameter stenosis (both P < .001). Conclusion The new morphologic index, α×LL/MLD4, incorporating lesion entrance angle achieved higher diagnostic performance in detecting hemodynamically significant lesions compared with diameter stenosis and LL/MLD4. Keywords: CT Angiography, Cardiac, Coronary Arteries, Ischemia, Infarction, Technology Assessment Clinical trial registration no. NCT03054324 Supplemental material is available for this article. © RSNA, 2023 See also the commentary by Fairbairn and Nørgaard in this issue.


Subject(s)
Coronary Stenosis , Fractional Flow Reserve, Myocardial , Female , Humans , Male , Middle Aged , Computed Tomography Angiography/methods , Constriction, Pathologic , Coronary Angiography/methods , Coronary Stenosis/diagnosis , Prospective Studies , Retrospective Studies , Aged
5.
Singapore Med J ; 2021 Oct 24.
Article in English | MEDLINE | ID: mdl-34688230

ABSTRACT

INTRODUCTION: Computed tomography angiography of the aorta (CTAA) is the modality of choice for investigating aortic disease. Our aim was to evaluate image quality, contrast enhancement and radiation dose of electrocardiograph (ECG)-triggered and non-ECG-triggered CTAA on a 256-slice single source CT scanner. Knowledge of these will allow requesting clinician and radiologist to balance radiation risk and image quality. METHODS: We retrospectively assessed data from 126 patients who had undergone CTAA on a single-source CT scanner using ECG-triggered (group 1, n = 77) or non-ECG-triggered (group 2, n =49) protocols. Radiation doses were compared. Qualitative (4-point scale) and quantitative image quality assessments were performed. RESULTS: The mean volume CT dose index, dose length product and effective dose in group 1 were 12.4 ± 1.9 mGy, 765.8 ± 112.4 mGy x cm and 13.0 ± 1.9 mSv, respectively. These were significantly higher compared with group 2 (9.1 ± 2.6 mGy, 624.1 ± 174.8 mGy x cm and 10.6 ± 3.0 mSv, respectively) ( p < 0.001). Qualitative assessment showed image quality at the aortic root-proximal ascending aorta was significantly higher in group 1 (median = 3) than in group 2 (median = 2, p < 0.001). Quantitative assessment showed significantly better mean arterial attenuation, signal-to-noise ratio and contrast-to-noise ratio in ECG-triggered CTAA compared with non-ECG-triggered CTAA. CONCLUSION: ECG-triggered CTAA in a single-source scanner has superior image quality and vessel attenuation of aortic root/ascending aorta but a higher radiation dose of approximately 23%. Its use should be considered specifically when assessing aortic root/ascending aorta pathology.

6.
Singapore Med J ; 61(3): 109-115, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32488269

ABSTRACT

Computed tomography coronary angiography (CTCA) is a robust and reliable non-invasive alternative imaging modality to invasive coronary angiography, which is the reference standard in evaluating the degree of coronary artery stenosis. CTCA has high negative predictive value and can confidently exclude significant coronary artery disease (CAD) in low to intermediate risk patients. Over the years, substantial effort has been made to reduce the radiation dose and increase the cost efficiency of CTCA. In this review, we present the evolution of computed tomography scanners in the context of coronary artery imaging as well as its clinical applications and limitations. We also highlight the future directions of CTCA as a one-stop non-invasive imaging modality for anatomic and functional assessment of CAD.


Subject(s)
Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed , Coronary Angiography/methods , Coronary Angiography/trends , Coronary Artery Disease/surgery , Humans , Stents , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/trends
8.
Singapore Med J ; 60(11): 554-559, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31781779

ABSTRACT

Lung cancer is the leading cause of cancer-related death around the world, being the top cause of cancer-related deaths among men and the second most common cause of cancer-related deaths among women in Singapore. Currently, no screening programme for lung cancer exists in Singapore. Since there is mounting evidence indicating a different epidemiology of lung cancer in Asian countries, including Singapore, compared to the rest of the world, a unique and adaptive approach must be taken for a screening programme to be successful at reducing mortality while maintaining cost-effectiveness and a favourable risk-benefit ratio. This review article promotes the use of low-dose computed tomography of the chest and explores the radiological challenges and future directions.


Subject(s)
Early Detection of Cancer/methods , Lung Neoplasms/diagnostic imaging , Mass Screening/methods , Radiology/organization & administration , Tomography, X-Ray Computed/methods , Algorithms , Clinical Trials as Topic , Cost-Benefit Analysis , Deep Learning , Diagnosis, Computer-Assisted , Europe , False Positive Reactions , Humans , Interdisciplinary Communication , Practice Guidelines as Topic , Public Health , Radiation Dosage , Registries , Risk Assessment , Singapore/epidemiology , Smoking Cessation , United States
12.
Pediatr Cardiol ; 37(8): 1397-1403, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27377528

ABSTRACT

The aim of this study was to investigate whether there is a reduction in radiation dose and improvement in image quality of pediatric cardiac computed tomography scans performed using the high-pitch spiral technique on a new third-generation dual-source 2 × 192-slice scanner (group B) compared with scans performed using the sequential technique on a single-source 256-slice scanner (group A). We performed a retrospective observational study on 40 patients aged ≤18 years who underwent prospectively electrocardiogram-triggered cardiac computed tomography. Image quality was assessed by pre-defined objective indices and a four-point subjective score. Apart from a higher mean heart rate in group A (P = 0.016), there were otherwise no significant inter-group differences in patient characteristics. The median effective dose was 4.41 mSv (interquartile range 2.58-5.90 mSv) in group A and 0.52 mSv (interquartile range 0.39-0.59 mSv) in group B (P < 0.001), representing a 88 % reduction. Subjective image quality score was significantly better in group B (4 = excellent with no artifact, mode 57.1 %) than in group A (3 = good with mild artifact, mode 57.9 %) (P < 0.001). Noise index, signal-to-noise ratio and contrast-to-noise ratio between both groups were not statistically significant. New third-generation dual-source high-pitch spiral scan technique can deliver excellent image quality with low radiation dose. Our results suggest that it should be considered as a first-choice technique for performing cardiac computed tomography in the pediatric population.


Subject(s)
Heart Diseases/diagnostic imaging , Child , Coronary Angiography , Electrocardiography , Humans , Radiation Dosage , Retrospective Studies , Tomography, Spiral Computed , Tomography, X-Ray Computed
14.
Eur Radiol ; 26(2): 398-406, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26032879

ABSTRACT

OBJECTIVES: Comparison of magnetic resonance elastography (MRE) and diffusion-weighted imaging (DWI) for differentiating malignant and benign focal liver lesions (FLLs). METHODS: Seventy-nine subjects with 124 FLLs (44 benign and 80 malignant) underwent both MRE and DWI. MRE was performed with a modified gradient-echo sequence and DWI with a free breathing technique (b = 0.500). Apparent diffusion coefficient (ADC) maps and stiffness maps were generated. FLL mean stiffness and ADC values were obtained by placing regions of interest over the FLLs on stiffness and ADC maps. The accuracy of MRE and DWI for differentiation of benign and malignant FLL was compared using receiver operating curve (ROC) analysis. RESULTS: There was a significant negative correlation between stiffness and ADC (r = -0.54, p < 0.0001) of FLLs. Malignant FLLs had significantly higher mean stiffness (7.9kPa vs. 3.1kPa, p < 0.001) and lower mean ADC (129 vs. 200 × 10(-3)mm(2)/s, p < 0.001) than benign FLLs. The sensitivity/specificity/positive predictive value/negative predictive value for differentiating malignant from benign FLLs with MRE (cut-off, >4.54kPa) and DWI (cut-off, <151 × 10(-3)mm(2)/s) were 96.3/95.5/97.5/93.3% (p < 0.001) and 85/81.8/88.3/75% (p < 0.001), respectively. ROC analysis showed significantly higher accuracy for MRE than DWI (0.986 vs. 0.82, p = 0.0016). CONCLUSION: MRE is significantly more accurate than DWI for differentiating benign and malignant FLLs. KEY POINTS: • MRE is superior to DWI for differentiating benign and malignant focal liver lesions. • Benign lesions with large fibrous components may have higher stiffness with MRE. • Cholangiocarcinomas tend to have higher stiffness than hepatocellular carcinomas. • Hepatocellular adenomas tend to have lower stiffness than focal nodular hyperplasia. • MRE is superior to conventional MRI in differentiating benign and malignant liver lesions.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Neoplasms/pathology , Magnetic Resonance Imaging/methods , Adult , Diagnosis, Differential , Diffusion Magnetic Resonance Imaging/methods , Female , Humans , Liver/pathology , Male , ROC Curve , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
15.
Singapore Med J ; 56(4): 198-201; quiz 202, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25917470

ABSTRACT

Levocardia (left-sided cardiac apex) with abdominal situs inversus is extremely rare. This is also known as isolated levocardia and is almost always associated with severe forms of congenital heart defects with poor prognosis. We report isolated levocardia in a 13-year-old symptomatic male patient. The purpose of this paper is to outline the imaging features of isolated levocardia and to highlight the role of cardiovascular magnetic resonance imaging (CMR) in the diagnosis and management of such cases. Other forms of cardiac malposition, including dextrocardia, mesocardia and criss-cross heart, with chest radiograph and CMR correlation, are also discussed.


Subject(s)
Abnormalities, Multiple/diagnosis , Diagnostic Imaging , Levocardia/diagnosis , Situs Inversus/diagnosis , Adolescent , Humans , Magnetic Resonance Imaging, Cine , Male , Radiography, Thoracic , Tomography, X-Ray Computed
16.
Singapore Med J ; 55(9): 462-6; quiz 467, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273929

ABSTRACT

We report the case of a 70-year-old man with an asymptomatic large patent ductus arteriosus (PDA) incidentally detected on triple-rule-out computed tomography (CT). CT clearly demonstrated a vascular structure connecting the descending thoracic aorta to the roof of the proximal left pulmonary artery, consistent with a PDA. Secondary pulmonary arterial hypertension was also evident on CT. The patient was eventually diagnosed with acute coronary syndrome and was successfully treated with coronary artery bypass graft surgery and concomitant patch closure of the PDA. This article aims to outline the imaging features of PDA and highlight the information provided by CT, which is crucial to treatment planning. The pathophysiology, clinical manifestations and closure options of PDA are also briefly discussed.


Subject(s)
Ductus Arteriosus, Patent/complications , Ductus Arteriosus, Patent/diagnostic imaging , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/diagnostic imaging , Tomography, X-Ray Computed , Aged , Aorta, Thoracic/diagnostic imaging , Echocardiography , Heart Diseases/congenital , Heart Diseases/diagnostic imaging , Humans , Infant , Male , Obesity/complications , Pulmonary Artery/pathology , Radiography, Thoracic , Treatment Outcome , Young Adult
17.
Singapore Med J ; 53(8): e176-8, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22941148

ABSTRACT

Double outlet right ventricle (DORV) is an uncommon congenital heart disease with a poor prognosis. We report a rare case of a girl with untreated DORV who survived until adolescence, but then developed infective endocarditis with florid complications and succumbed to it. Although infective endocarditis is seldom encountered in children in developed countries, a high index of suspicion is required for those with congenital heart disease. The roles of cross-sectional imaging are demonstrated, including the usefulness of magnetic resonance imaging not only in evaluating congenital heart disease, but also in detecting incidental lesions in the extracardiac structures.


Subject(s)
Double Outlet Right Ventricle/complications , Endocarditis/etiology , Adolescent , Endocarditis/diagnosis , Fatal Outcome , Female , Humans
18.
J Digit Imaging ; 24(4): 598-608, 2011 Aug.
Article in English | MEDLINE | ID: mdl-20623156

ABSTRACT

Segmentation of the left ventricle is important in the assessment of cardiac functional parameters. Manual segmentation of cardiac cine MR images for acquiring these parameters is time-consuming. Accuracy and automation are the two important criteria in improving cardiac image segmentation methods. In this paper, we present a comprehensive approach to segment the left ventricle from short axis cine cardiac MR images automatically. Our method incorporates a number of image processing and analysis techniques including thresholding, edge detection, mathematical morphology, and image filtering to build an efficient process flow. This process flow makes use of various features in cardiac MR images to achieve high accurate segmentation results. Our method was tested on 45 clinical short axis cine cardiac images and the results are compared with manual delineated ground truth (average perpendicular distance of contours near 2 mm and mean myocardium mass overlapping over 90%). This approach provides cardiac radiologists a practical method for an accurate segmentation of the left ventricle.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Pattern Recognition, Automated/methods , Ventricular Dysfunction, Left/diagnosis , Algorithms , Humans , Image Enhancement/methods , Ventricular Dysfunction, Left/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...