Diabetol Int ; 12(2): 145-150, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33786269

ABSTRACT

AIMS: To evaluate the sensitivity and specificity of the Ipswich touch test for the screening of loss of protective sensation in patients with diabetes mellitus based on the current literature. METHODS: Three electronic databases were searched for eligible studies that investigated the sensitivity and specificity of the Ipswich touch test. Methodological quality was assessed using the QUADAS-2 tool. RESULTS: Five studies that reported the sensitivity and specificity of the Ipswich touch test were included. When compared to the 10 g monofilament, the sensitivity ranges from 51 to 83.3% and the specificity ranges from 96.4 to 98%. When compared to the vibration perception test ≥25 V, Ipswich touch test sensitivity ranges from 76 to 100% and specificity ranges from 90 to 96.6%. CONCLUSIONS: The Ipswich touch test has a high specificity in screening for loss of protective sensation in the feet of patients with diabetes mellitus. It is a useful test to be included in diabetic foot screenings, especially when other sensory tools are not available. However, more rigorous studies need to be conducted as there is currently only a limited pool of research evidence to substantiate it as a screening tool for loss of protective sensation in the diabetic foot.