Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 16(5): e60602, 2024 May.
Article in English | MEDLINE | ID: mdl-38894768

ABSTRACT

AIM: Over-the-counter teeth-whitening products have become popular in accordance with the increasing demands of patients. These products can also be recommended to patients by dentists. The aim was to determine the rates of recommendation of over-the-counter teeth whitening products by dentists in Turkey divided into different categories for their patients and to interpret them based on a cause-and-effect relationship. MATERIAL AND METHODS: After obtaining ethics committee approval, the survey questions were created using Google Forms (Google Inc., Mountainview, CA) and delivered to dentists via social media. Dentists who signed the informed consent form completed the survey. Within the study's scope, statistical analyses were conducted using IBM SPSS Statistics for Windows, version 26.0 (IBM Corp., Armonk, NY). Values were expressed as frequency (n) and percentage (%). A chi-square test was used to compare participants' teeth-whitening recommendations according to their demographic characteristics. The statistical significance level was accepted as p <0.05 throughout the study. RESULTS: A total of 57.9% of dentists working in Turkey did not recommend over-the-counter teeth-whitening products to their patients. When the answers to the question "Which whitening products sold on the market do you recommend to your patients?" were compared according to the participants' place of work, there was a statistically significant difference between the place of work and the recommended whitening product (p <0.05). Participants working in the private sector answered "I do not recommend" at a higher rate than participants working in the public sector. Among those who recommended toothpaste, more dentists with five or fewer years of experience recommended toothpaste to their patients than dentists with greater than five years of experience. Additionally, more dentists working in the public sector recommended toothpaste to their patients than dentists working in the private sector, and more specialist dentists recommended toothpaste to their patients than general practitioner dentists. CONCLUSION: Most dentists in Turkey do not recommend over-the-counter teeth-whitening products to their patients. Among those who recommend such products, toothpaste has been determined to be the first choice. The results of this study may raise awareness among dentists about over-the-counter teeth-whitening products and encourage new studies.

2.
Proc Inst Mech Eng H ; : 9544119241248232, 2024 May 05.
Article in English | MEDLINE | ID: mdl-38706301

ABSTRACT

The aim of this study was to evaluate the effect of rotation frequency (rpm) of different polishing discs on the surface roughness of a nanohybrid resin composite material. 126 specimens were prepared in metal molds of 10 mm diameter and 2 mm depth using a nanohybrid resin composite material. The prepared specimens were kept in distilled water for 24 hours. Polishing treatments at 5k, 10k, 15k, and 20k rpm were applied to the nanohybrid resin composite material by grouping different brand polishing discs: Sof-Lex Contouring and Polishing Discs (3M Espe, USA) (3M Group), Optidisc (Kerr Corporation, USA) (Kerr Group), Super-Snap Rainbow Technique Kit (Shofu Dental, Japan) (Shofu Group), Finishing Disc (Bisco Dental, USA) (Bisco Group). The surface roughness was evaluated at three different points by atomic force microscopy for all specimens and scanning electron microscopy was used for visual assessment. Data were evaluated by Two Way ANOVA and Tukey's HSD Test. The mean surface roughness (Ra, µm) of all prepared samples showed significant differences (α = 0.05). According to Two-Way ANOVA, there is a statistically significant relationship between the rpm values and the discs. The 3M group showed the highest roughness value at all rpm speeds. Shofu group at 15k, 20k rpm, Bisco group at 10k, 15k, 20k rpm, the Kerr group at 15k, 20k rpm showed the lowest roughness value and had roughness close to the surfaces finished with a mylar strip. The smoothest surfaces were obtained at 15k rpm, even though polishing discs from different brands were used. It was also observed that 5k and 20k rpm polishing speeds can increase the surface roughness of the nanohybrid resin composite material.

3.
Cureus ; 15(9): e46225, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37908912

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the color stability of smart monochromatic composite resin after coloring with coffee solution, thermal aging and brushing with four different kinds of toothpaste. MATERIALS AND METHODS: According to the manufacturer's instructions, 40 smart monochromatic composite resin (Omnichroma, Tokuyama Dental, Japan) specimens were prepared with a thickness of 2 mm and a diameter of 10 mm. The samples were divided into four groups. The first group (SFM) was brushed with Sensodyne Fresh Mint (Sensodyne GSK, UK), the second group (CW) with Colgate 2 in 1 Whitening (Colgate Palmolive, USA), the third group (OW) with Opalescence Whitening (Ultradent Products, Inc., USA), the fourth group (COW) with Colgate Optic White With Charcoal (Colgate Palmolive, USA). At time point t0, no brushing and thermal cycles were performed. For time point t1, simulations corresponding to 10 days of staining, thermal aging and brushing were performed. For time point t2, simulations corresponding to one year of staining, thermal aging and brushing were performed. The color of all specimens was measured at t0, t1 and t2 with a spectrophotometer. To examine the color change, ΔE00 values were calculated with the CIEDE 2000 color system. Shapiro Wilk, Kolmogorov Smirnov, Wilcoxon Signed Rank, Kruskal Wallis, and Mann-Whitney U tests were used to analyze the data. RESULTS: According to the results of the intergroup comparison, there is no statistically significant difference between the groups in ΔE00(t0-t1) values in terms of t0-t1 time period measurement (p>0.05). There is a statistically significant difference between the groups in ΔE00(t1-t2)values in terms of t1-t2 time period measurement (p<0.05). The COW group had the lowest ΔE00(t1-t2) value and the OW group had the highest ΔE00(t1-t2) value. There is a statistically significant difference between the groups in ΔE00 (t0-t2) values in terms of t0-t2 time period measurement (p<0.05). The COW group had the lowest ΔE00(t0-t2) value and the OW group had the highest ΔE00(t0-t2) value. CONCLUSION: The whitening efficacy of different kinds of toothpaste whitening mechanisms may differ from each other. Toothpastes also show whitening on composite resins. The lowest discoloration was observed in the group brushed with toothpaste containing activated charcoal and blue covarine. The efficacy of whitening toothpastes should be supported by in vivo studies.

4.
Cureus ; 15(8): e44309, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37779740

ABSTRACT

AIM: The aim of the present study is to compare the repair bond strengths (RBSs) of Cention-N (light-cure and self-cure modes), Equia Forte HT Fil and a nanohybrid resin composite. MATERIALS AND METHODS: Equia Forte HT Fil (GC, Tokyo, Japan), Cention-N (Ivoclar Vivadent, Schaan, Liechtenstein) and Filtek Z550 (3M ESPE, St Paul, MN, USA) were used in this study. Equia Forte HT Fil (EQF), Cention-N self-cure (CSC), Cention-N light-cure (CLC) and Filtek Z550 (Z550) groups were formed. A total of 40 samples were prepared; 10 samples in each group (n = 10). After the polymerization was completed according to the manufacturer's instructions, the samples were polished with OptiDisc (Kerr Corporation, Orange, USA) for 5 s each, from extra-course to extra-fine. After all samples were stored in 37°C water for 24 h, 10,000 cycles of brushing simulator and thermal cycles were applied to the samples. The samples were prepared in accordance with the selected repair protocol, and microshear bond strength (µSBS) test was performed. Fracture analysis on debonded surfaces was visualized by scanning electron microscopy. The conformity of the data to normal distribution was analyzed by the Shapiro-Wilk test. Multiple comparisons were performed using Dunn's test. RESULTS:  Z550 showed significantly higher µSBS as compared to the other three groups. There is no difference between CSC, CLC and EQF. CONCLUSION: The use of Cention-N's self-cure or light-cure mode did not affect the RBS values. The RBS values of Cention-N and Equia Forte HT Fil materials are lower than those of the composite resin material.

5.
J Conserv Dent ; 26(1): 36-41, 2023.
Article in English | MEDLINE | ID: mdl-36908727

ABSTRACT

Aims and Objectives: The objective of this study was to compare surface roughness of a nano-spherical resin composite using four different multi-step polishing disc systems at five different speeds. Materials and Methods: In total, 154 discs samples were prepared using a supra-nano spherical resin composite. The samples were divided into negative and positive control groups and the following four finishing and polishing disc systems: Sof-Lex, Bisco Finishing Discs, OptiDisc, and Super-Snap. Each polishing disc system was applied at five different speeds (2000, 5000, 10,000, 15,000, and 20,000 revolutions per minute [RPM]) (n = 7). The surface roughness of samples was measured using a profilometer. One sample from each group was evaluated by scanning electron microscopy and atomic force microscopy. Two-way analysis of variance was used to evaluate the average roughness (Ra) data from the profilometric experiments using statistical software (GraphPad Prism4-GraphPad Software; La Jolla, CA, USA). The mean values were compared using the Bonferroni test (P = 0.05). Results: The mean roughness ranged from 0.07 µm to 0.41 µm. The smoothest surfaces were obtained with OptiDisc at 20,000 RPM and Super-Snap at 20,000 RPM. The Bisco Finishing Discs group at 2,000 RPM showed the highest surface roughness values. For all polishing systems, the roughness at 20,000 RPM was lower than that at other speeds. Conclusion: Within the limitations of the present in vitro study, it can be concluded that the polishing performance was in the following order: Super-Snap > OptiDisc > Sof-Lex > Bisco Finishing Discs. In addition, the surface roughness decreased as the polishing speed increased.

SELECTION OF CITATIONS
SEARCH DETAIL
...