Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Exp Dermatol ; 47(10): 1895-1897, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36002914

ABSTRACT

Cutis laxa (CL) comprises a heterogeneous group of entities mainly classified as X-linked, autosomal dominant and recessive forms, which differ in severity. We encountered a CL baby with no familial history. We performed targeted exome sequencing, and detected a de novo heterozygous frameshift mutation in the elastin gene of the baby.


Subject(s)
Cutis Laxa , Cutis Laxa/genetics , Elastin/genetics , Exome/genetics , Frameshift Mutation , Humans , Infant , Mutation
3.
PDA J Pharm Sci Technol ; 72(4): 420-437, 2018.
Article in English | MEDLINE | ID: mdl-29545322

ABSTRACT

Recently, the use of filters has come into light for sanitizing water plants. This study investigated the role of heat-tolerant ultrafilters (UFs) for the remediation of reverse osmosis (RO) plants using periodic thermal disinfection. Two completely identical RO plants (RO plants A and B) were installed in 2006 for surgical hand antisepsis in the operating theater. RO water was stored in the 300 L storage tank and recirculated in the 190 meter-long loop delivering water to 12 faucets in each RO plant. Periodic thermal disinfection came into practice periodically when a UF module was retrofitted to the recirculation loop of each RO plant in 2010. Endotoxin was monitored closely before and after thermal disinfection. Before UF modules were retrofitted, endotoxin increased to a maximum of 0.301 EU/mL in RO plant A and 1.446 EU/mL in RO plant B after thermal disinfection, respectively. Since a UF module was retrofitted to each RO plant in 2010, endotoxin has been continuously below 0.025 EU/mL in RO plant A and exceeded this level five times in RO plant B. On one occasion, endotoxin increased in all samples collected simultaneously after solenoid valves were replaced in the recirculation loop near the air conditioner outlet. At this time, the inside of the pipework was exposed to the ventilation airflow. After the valves were replaced again, this time with the workplace isolated using a curing sheet, endotoxin decreased. On the other occasions, endotoxin increased only in one sample and decreased after thermal disinfection. Annually replaced UF modules were examined twice for estimating the amounts of immobilized endotoxin. The estimated amounts decreased in 2013 by the order of 10-3 in comparison with those in 2011 in both RO plants. The present study suggested that UFs acted synergistically with periodic thermal disinfection for the remediation of RO plants.


Subject(s)
Antisepsis/methods , Disinfection/methods , Hand Disinfection/methods , Water Purification/methods , Endotoxins/isolation & purification , Filtration/methods , Hot Temperature , Humans , Longitudinal Studies , Operating Rooms/standards , Osmosis , Water/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...