Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
Rev Port Cardiol ; 42(4): 363-370, 2023 04.
Article in English, Portuguese | MEDLINE | ID: mdl-36634763

ABSTRACT

BACKGROUND: Cryoballoon ablation (CBA) for pulmonary vein isolation (PVI) has been growing as an alternative technique, not only in patients with paroxysmal atrial fibrillation (PAF) but also in persistent atrial fibrillation (AF). Cryoballoon ablation has demonstrated encouraging acute and mid-term results. However, data on long-term follow-up of CB-based PVI are scarce. OBJECTIVE: We sought to examine efficacy, safety, and long-term outcomes of CBA in PAF and persistent AF in four Portuguese centers. METHODS: All patients that were treated with the cryoballoon catheter according to routine practices with a second-generation 28-mm CB in four centers were included. This was a retrospective, non-randomized analysis. Patients were followed-up for >12 months and freedom from atrial arrhythmias (AA) was evaluated at the end of follow-up. RESULTS: Four hundred and six patients (57.7±12.4 years, 66% men) participated. AF was paroxysmal in 326 patients (80.2%) and persistent in 80 (19.7%). The mean procedure time duration was 107.7±50.9 min, and the fluoroscopy time was 19.5±9.7 min. Procedural/periprocedural complications occurred in 30 cases (7.3%), being transient phrenic nerve palsy the most frequent incident (2 out of 3 complications). Anatomic variations of the PV were present in 16.1% of cases. At a mean follow-up of 22.0±15.0 months, 310 patients (76.3%) remained in stable sinus rhythm, with at least one AF episode recurrence documented in 98 cases (24.1%). The recurrence rate was 20.5% in the PAF group and 37.8% in the persistent AF group. CONCLUSION: In this multicenter experience, a single CBA procedure resulted in 75.9% freedom from AF at a 22-month follow-up. This technique was demonstrated to be a safe and effective option in experienced centers for the treatment of PAF and PersAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Male , Humans , Female , Atrial Fibrillation/complications , Portugal , Treatment Outcome , Retrospective Studies , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence
3.
Rev Port Cardiol ; 33(5): 311.e1-5, 2014 May.
Article in English, Portuguese | MEDLINE | ID: mdl-24931177

ABSTRACT

The classic transvenous implantation of a permanent pacemaker in a pectoral location may be precluded by obstruction of venous access through the superior vena cava or recent infection at the implant site. When these barriers to the procedure are bilateral and there are also contraindications or technical difficulties to performing a thoracotomy for an epicardial approach, the femoral vein, although rarely used, can be a viable alternative. We describe the case of a patient with occlusion of both subclavian veins and a high risk for mini-thoracotomy or videothoracoscopy, who underwent implantation of a permanent single-chamber pacemaker via the right femoral vein.


Subject(s)
Femoral Vein , Pacemaker, Artificial , Female , Humans , Middle Aged , Prosthesis Implantation/methods
5.
Rev Port Cardiol ; 30(9): 711-6, 2011 Sep.
Article in Portuguese | MEDLINE | ID: mdl-21958995

ABSTRACT

UNLABELLED: Ventilatory efficiency, evaluated by cardiopulmonary exercise testing (CPET), has considerable prognostic value in patients with chronic heart failure (CHF) due to left ventricular systolic dysfunction (LVSD). Its determinants nevertheless remain controversial. AIM: To investigate the possible correlation between parameters of ventilatory efficiency obtained by CPET and thoracic fluid content (TFC), assessed by thoracic electrical bioimpedance (TEB), in patients with CHF due to LVSD. METHODS: We studied 120 patients with LVSD and CHF, referred to our laboratory for CPET: 76% male, age 52.1 ± 12.1 years, 37% of ischemic etiology, left ventricular ejection fraction 27.6 ± 7.9%, 83% in sinus rhythm, 96% receiving ACEIs and/or ARBs and 79% beta-blockers, and 20% treated with a cardiac resynchronization device. TEB studies were performed after 15 minutes of rest, prior to symptom-limited treadmill CPET, using the modified Bruce protocol. CPET-derived peak oxygen consumption (pVO(2)), the slope of the relationship between minute ventilation (VE) and carbon dioxide production (VCO(2)), VE/VCO(2) at the anaerobic threshold (AT), and TFC assessed by TEB were considered for analysis. RESULTS: TFC ranged between 20.6 and 45.8kOhm-1, mean 32.2, SD=5.7, median 32.7, pVO(2) 8.9-40.6 ml/kg/min, mean 21.0, SD 6.2, median 20.2, VE/VCO(2) slope 19.8-60.7, mean 30.7, SD 7.9, median 29.1 and VE/VCO(2) at AT 21-62, mean 33.1, SD 7.5, median 31.5. By linear regression, TFC did not correlate with pVO(2) (r=0.05, p=0.58), but showed correlation with parameters of ventilatory efficiency: r=0.20, p=0.032, r(2)=0.04 for VE/VCO(2) slope and r=0.25, p=0.009, r(2)=0.06 for VE/VCO(2) at AT. CONCLUSION: TFC correlates with CPET parameters of ventilatory efficiency in patients with CHF due to LVSD, suggesting that it may be one of its determinants.


Subject(s)
Heart Failure/complications , Heart Failure/physiopathology , Pericardial Effusion/etiology , Pleural Effusion/etiology , Pulmonary Ventilation , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...