Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eur J Cardiothorac Surg ; 27(1): 156-8, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15621491

ABSTRACT

We present a possible alternative technique to treat the rupture of aortic arch aneurysms on beating heart without necessity of cardiopulmonary bypass (CPB), hypothermic circulatory arrest and cerebral protection, using a bifurcated vascular prosthesis to revascularize the subclavian and carotid arteries and an endovascular prosthesis to repair the aortic arch. We report the case of a 78-year-old woman successfully treated with this technique. Since in our institution endovascular prostheses are placed by the interventional cardiologists, the operation was done in cooperation between cardiac surgeons and interventional cardiologists.


Subject(s)
Aneurysm, Ruptured/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Aged , Carotid Arteries/surgery , Carotid Stenosis/surgery , Female , Humans , Subclavian Artery/surgery , Subclavian Steal Syndrome/surgery
2.
Eur J Cardiothorac Surg ; 22(4): 571-5, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12297174

ABSTRACT

OBJECTIVES: The role of the sternal closure techniques on the incidence of sternal dehiscence and wound infection are well defined among a high number of other variables involved. In the various series, the incidence of wound complication in cardiac surgery varies from 2 to 8%. The aim of our study is to evaluate the role of thermal-dependent shape-memory Nitillium clips in reducing the incidence of sternal dehiscence following sternotomy. METHODS: We perspectively randomized 1000 consecutive patients requiring cardiac surgery to evaluate the incidence of sternal wound complications (SWC), sternal dehiscence and/or other related complications. We compared Group I (500 patients), in which sternal closure was achieved with standard sternal wires, with Group II (500 patients), in which sternal approximation was carried out by means of thermoreactive Nitillium clips. The two randomized groups were comparable in terms of age, gender, Euroscore and risk factors for sternal/wound complications. RESULTS: In our study the overall incidence of SWC was 4.7%. The incidence of SWC was considerably higher in Group I (6.8%) when compared to Group II (2.6%) (P=0.003). Mechanical sternal dehiscence without infection occurred in 14 patients in Group I and in one patient in Group II (P=0.002). Despite sternotomy wound infection occurred similarly in both groups (15 patients in Group I vs. 12 patients in Group II), sternal revision was performed only in patients of Group I (Group I: 9/15 vs. Group II: 0/12; P=0.001). CONCLUSION: Thermal shape-memory Nitillium clips provided superior results in sternal osteosynthesis following midline sternotomy, due to a considerable reduction of sternal dehiscence and related complications. The clinical benefit of Nitillium clips was demonstrated even in patients with several risk factors for SWC.


Subject(s)
Sternum/surgery , Surgical Instruments , Surgical Wound Dehiscence/prevention & control , Surgical Wound Infection/prevention & control , Aged , Bone Wires , Chi-Square Distribution , Female , Heart Diseases/pathology , Heart Diseases/surgery , Humans , Incidence , Male , Middle Aged , Osteogenesis , Osteonecrosis/etiology , Prospective Studies , Reoperation , Sternum/pathology
3.
Ital Heart J Suppl ; 1(5): 674-8, 2000 May.
Article in Italian | MEDLINE | ID: mdl-10834133

ABSTRACT

BACKGROUND: The authors report their preliminary experience of endoscopic saphenous vein harvesting as part of a program devoted to reducing the invasivity of surgical myocardial revascularization. This method allows us to minimize the cutaneous incisions in the inferior limbs necessary to harvest the saphenous vein, thus reducing the incidence of complications. METHODS: The study includes 41 patients who underwent endoscopic saphenous vein harvesting from October 1998 to September 1999 and, as a control group, 20 patients with similar characteristics operated on with the traditional technique during the same period. The variables considered were: the time necessary to harvest the saphenous vein, the incidence of complications, and the postoperative mobilization. RESULTS: All the endoscopically harvested grafts were adequate for the scheduled procedure. The only complication occurred in a patient operated on with the traditional technique. The time of harvesting and the day of mobilization were similar in the two groups. The reduction of surgical trauma allowed a fast deambulation recovery and better esthetic results. CONCLUSIONS: When complete arterial revascularization is not feasible, the endoscopic harvesting of the required saphenous vein segment allows for a significant reduction in the invasivity of the procedure.


Subject(s)
Endoscopy/methods , Myocardial Revascularization/methods , Saphenous Vein/transplantation , Tissue and Organ Harvesting/methods , Adult , Aged , Endoscopes , Female , Humans , Male , Middle Aged , Time Factors , Treatment Outcome , Video Recording/instrumentation
4.
Thorac Cardiovasc Surg ; 43(1): 52-6, 1995 Feb.
Article in English | MEDLINE | ID: mdl-7540330

ABSTRACT

From 1982 through March 1994, fourty-seven patients underwent completion pneumonectomy for a reappearing lung cancer, lung metastases, late complications, benign lung diseases, and early complication of bronchial or pulmonary artery sleeve resections. Intraoperative bleeding was higher than in standard pneumonectomy; there was one intraoperative mortality (2.3%). Operative mortality was 14.9% overall but was 3.6% in completion pneumonectomy for lung cancer, 20% for late complications and benign disease, and 57% for the treatment of early complications of sleeve resections. Three and five-year survival in patients with lung cancer who survived the operation was 43.8% and 28.7% according to the Kaplan-Meier method; no significant difference in long-term survival was present between patients with a second primary lung cancer or recurrence. Completion pneumonectomy is indicated in reappearing lung cancer and should be considered in benign disease when a less invasive procedure is not available. Completion pneumonectomy for the treatment of early complications of bronchial or pulmonary artery sleeve resections has a very high mortality but no alternative is available.


Subject(s)
Pneumonectomy , Female , Humans , Lung Diseases/surgery , Lung Neoplasms/secondary , Lung Neoplasms/surgery , Male , Middle Aged , Neoplasm Recurrence, Local , Pneumonectomy/mortality , Reoperation , Survival Rate
5.
Thorac Cardiovasc Surg ; 42(2): 81-4, 1994 Apr.
Article in English | MEDLINE | ID: mdl-8016833

ABSTRACT

The incidence of chylothorax after pleuro-pulmonary operations as well as its treatment is reported. Of 1744 operations performed postoperative chylothorax developed in 13 (0.74%). It resulted in two cases from the transection of the thoracic duct, in six from the transection of the so-called minor lymph channels, which drain lymph from mediastinal nodes straight into the thoracic duct or drain lung segments into the thoracic duct via the pulmonary ligament; the transection of these channels occurred during mediastinal lymphadenectomy or during the section of the pulmonary ligament. In 5 patients the site of leakage was not determined as reoperation was not required. Conservative treatment with low-fat diet and medium-chain triglycerides and/or total parenteral nutrition was attempted in all but one patient but was successful only in 5 cases whose mean losses were 292 ml/day. Seven patients were reoperated after a mean of 11 days; their mean losses were 930 ml/day. One patient was reoperated on the third postoperative day without attempting conservative treatment; his mean loss was 850 ml/day. Lymphadenectomy seems to be an important risk factor for postoperative chylothorax. Chyle leakage around 500 ml/day or higher that tends to decrease below 500 ml/day after a few days of dietary manipulation usually stops within 10-20 days, while leakage over 500 ml/day that does not tend to decrease below 500 ml/day seldom if ever stops without surgery, so that a more aggressive attitude is justified.


Subject(s)
Chylothorax/etiology , Lung Diseases/surgery , Lung Neoplasms/surgery , Pleural Diseases/surgery , Pleural Neoplasms/surgery , Postoperative Complications/etiology , Adult , Aged , Chest Tubes , Chylothorax/therapy , Female , Humans , Male , Middle Aged , Parenteral Nutrition, Total , Pneumonectomy , Postoperative Complications/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...