1.
J Clin Med ; 10(2)2021 Jan 07.
Article in English | MEDLINE | ID: mdl-33430489

ABSTRACT

OBJECTIVES: In idiopathic pulmonary fibrosis (IPF), alterations in the pulmonary surfactant system result in an increased alveolar surface tension and favor repetitive alveolar collapse. This study aimed to assess the usefulness of electrical impedance tomography (EIT) in characterization of regional ventilation in IPF. MATERIALS AND METHODS: We investigated 17 patients with IPF and 15 healthy controls from the University of Giessen and Marburg Lung Center (UGMLC), Germany, for differences in the following EIT parameters: distribution of ventilation (TID), global inhomogeneity index (GI), regional impedance differences through the delta of end-expiratory lung impedance (dEELI), differences in surface of ventilated area (SURF), as well as center of ventilation (CG) and intratidal gas distribution (ITV). These parameters were assessed under spontaneous breathing and following a predefined escalation protocol of the positive end-expiratory pressure (PEEP), applied through a face mask by an intensive care respirator (EVITA, Draeger, Germany). RESULTS: Individual slopes of dEELI over the PEEP increment protocol were found to be highly significantly increased in both groups (p < 0.001) but were not found to be significantly different between groups. Similarly, dTID slopes were increasing in response to PEEP, but this did not reach statistical significance within or between groups. Individual breathing patterns were very heterogeneous. There were no relevant differences of SURF, GI or CGVD over the PEEP escalation range. A correlation of dEELI to FVC, BMI, age, or weight did not forward significant results. CONCLUSIONS: In this study, we did see a significant increase in dEELI and a non-significant increase in dTID in IPF patients as well as in healthy controls in response to an increase of PEEP under spontaneous breathing. We propose the combined measurements of EIT and lung function to assess regional lung ventilation in spontaneously breathing subjects.

2.
BMC Neurol ; 20(1): 374, 2020 Oct 12.
Article in English | MEDLINE | ID: mdl-33045989

ABSTRACT

BACKGROUND: Percutaneous dilatational tracheostomy (PDT) has become a widely performed technique in neurocritical care, which is however known to be accompanied by some risks to the patient. The aim of this pilot study was to assess the derecruitment effects of PDT with the electric impedance tomography (EIT) during the PDT procedure in neurocritical care. METHODS: The prospective observational pilot study investigated 11 adult, intubated, mechanically ventilated patients with acute brain disease. We recorded EIT data to determine regional ventilation delay standard deviation (RVD SD), compliance win (CW) and loss (CL), end-expiratory lung impedance (EELI), with the EIT belt placed at the level of Th 4 before, during and after the PDT, performed in the standard PDT position ensuring hyperextension of the neck. RESULTS: From 11 patients, we finally analyzed EIT data in 6 patients - EIT data of 5 patients have been excluded due to the insufficient EIT recordings. The mean RVD SD post-PDT decreased to 7.00 ± 1.29% from 7.33 ± 1.89%. The mean post-PDT CW was 27.33 ± 15.81 and PDT CL 6.33 ± 6.55. Only in one patient, where the trachea was open for 170 s, was a massive dorsal collapse (∆EELI - 25%) detected. In other patients, the trachea was open from 15 to 50 s. CONCLUSIONS: This pilot study demonstrated the feasibility of EIT to detect early lung derecruitment occurring due to the PDT procedure. The ability to detect regional changes in ventilation could be helpful in predicting further progression of ventilation impairment and subsequent hypoxemia, to consider optimal ventilation regimes or time-schedule and type of recruitment maneuvres required after the PDT.


Subject(s)
Electric Impedance , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Tomography/methods , Tracheostomy/adverse effects , Adult , Critical Care/methods , Female , Humans , Lung Diseases/etiology , Lung Diseases/prevention & control , Male , Middle Aged , Neurology/instrumentation , Neurology/methods , Pilot Projects , Prospective Studies , Respiration , Respiration, Artificial/methods , Tracheostomy/methods
3.
Sci Rep ; 9(1): 9796, 2019 07 05.
Article in English | MEDLINE | ID: mdl-31278297

ABSTRACT

It is crucial to precisely monitor ventilation and correctly diagnose ventilation-related pathological states for averting lung collapse and lung failure in Intensive Care Unit (ICU) patients. Although Electrical Impedance Tomography (EIT) may deliver this information continuously and non-invasively at bedside, to date there are no studies that systematically compare EIT and Dual Energy CT (DECT) during inspiration and expiration (ΔDECT) regarding varying physiological and ICU-typical pathological conditions such as atelectasis. This study aims to prove the accuracy of EIT through quantitative identification and monitoring of pathological ventilation conditions on a four-quadrant basis using ΔDECT. In a cohort of 13 pigs, this study investigated systematic changes in tidal volume (TV) and positive end-expiratory pressure (PEEP) under physiological ventilation conditions. Pathological ventilation conditions were established experimentally by single-lung ventilation and pulmonary saline lavage. Spirometric data were compared to voxel-based entire lung ΔDECT, and EIT intensities were compared to ΔDECT of a 12-cm slab of the lung around the EIT belt, the so called ΔDECTBelt. To validate ΔDECT data with spirometry, a Pearson's correlation coefficient of 0.92 was found for 234 ventilation conditions. Comparing EIT intensity with ΔDECT(Belt), the correlation r = 0.84 was found. Normalized cross-correlation function (NCCF) between scaled global impedance (EIT) waveforms and global volume ventilator curves was r = 0.99 ± 0.003. The EIT technique correctly identified the ventilated lung in all cases of single-lung ventilation. In the four-quadrant based evaluation, which assesses the difference between end-expiratory lung volume (ΔEELV) and the corresponding parameter in EIT, i.e. the end-expiratory lung impedance (ΔEELI), the Pearson's correlation coefficient of 0.94 was found. The respective Pearson's correlation coefficients implies good to excellent concurrence between global and regional EIT ventilation data validated by ventilator spirometry and DECT imaging. By providing real-time images of the lung, EIT is a promising, EIT is a promising, clinically robust tool for bedside assessment of regional ventilation distribution and changes of end-expiratory lung volume.


Subject(s)
Pulmonary Ventilation , Respiratory Function Tests , Tomography, X-Ray Computed , Tomography , Animals , Data Analysis , Electric Impedance , Image Processing, Computer-Assisted , Monitoring, Physiologic , Swine , Tomography/methods , Tomography, X-Ray Computed/methods
4.
J Intensive Care ; 6: 18, 2018.
Article in English | MEDLINE | ID: mdl-29564137

ABSTRACT

BACKGROUND: Prone positioning may provide a uniform distribution of transpulmonary pressure and contribute to prevent ventilator-induced lung injury. However, despite moderate positive end-expiratory pressure and low tidal volumes, there is still a risk of regional overdistension. CASE PRESENTATION: A man with refractory hypoxemia was mechanically ventilated with prone positioning. Although prone positioning with a plateau pressure of 18 cmH2O and a positive end-expiratory pressure of 8 cmH2O promptly improved oxygenation, regional ventilation monitoring using electrical impedance tomography initially detected decreased distribution in the dorsal region but increased in the ventral, suggesting overdistension. CONCLUSIONS: Our experience indicates monitoring regional ventilation distribution is useful for decreasing the risk of overdistension during prone positioning.

5.
Thorax ; 72(1): 83-93, 2017 01.
Article in English | MEDLINE | ID: mdl-27596161

ABSTRACT

Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.


Subject(s)
Electric Impedance , Lung Diseases/diagnostic imaging , Lung Diseases/physiopathology , Tomography , Adolescent , Adult , Cardiac Output , Child , Child, Preschool , Consensus , Humans , Infant , Infant, Newborn , Lung Diseases/therapy , Pulmonary Circulation , Respiration, Artificial , Terminology as Topic , Tomography/methods
6.
Crit Care ; 20: 3, 2016 Jan 08.
Article in English | MEDLINE | ID: mdl-26743570

ABSTRACT

BACKGROUND: Electrical impedance tomography (EIT) is a non-invasive bedside tool which allows an individualized ventilator strategy by monitoring tidal ventilation and lung aeration. EIT can be performed at different cranio-caudal thoracic levels, but data are missing about the optimal belt position. The main goal of this prospective observational study was to evaluate the impact of different electrode layers on tidal impedance variation in relation to global volume changes in order to propose a proper belt position for EIT measurements. METHODS: EIT measurements were performed in 15 mechanically ventilated intensive care patients with the electrode belt at different thoracic layers (L1-L7). All respiratory and hemodynamic parameters were recorded. Blood gas analyses were obtained once at the beginning of EIT examination. Off-line tidal impedance variation/tidal volume (TV/VT) ratio was calculated, and specific patterns of impedance distribution due to automatic and user-defined adjustment of the colour scale for EIT images were identified. RESULTS: TV/VT ratio is the highest at L1. It decreases in caudal direction. At L5, the decrease of TV/VT ratio is significant. We could identify patterns of diaphragmatic interference with ventilation-related impedance changes, which owing to the automatically adjusted colour scales are not obvious in the regularly displayed EIT images. CONCLUSIONS: The clinical usability and plausibility of EIT measurements depend on proper belt position, proper impedance visualisation, correct analysis and data interpretation. When EIT is used to estimate global parameters like VT or changes in end-expiratory lung volume, the best electrode plane is between the 4th and 5th intercostal space. The specific colour coding occasionally suppresses user-relevant information, and manual rescaling of images is necessary to visualise this information.


Subject(s)
Durable Medical Equipment , Electric Impedance/therapeutic use , Positive-Pressure Respiration/methods , Tomography/instrumentation , Tomography/methods , Aged , Electrodes , Female , Humans , Male , Middle Aged , Patient Positioning/methods , Patient Positioning/standards , Prospective Studies , Tidal Volume/physiology