Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Int J Cardiol ; 127(1): 98-102, 2008 Jun 23.
Article in English | MEDLINE | ID: mdl-18280596

ABSTRACT

BACKGROUND: Pulsed-wave ultraviolet excimer laser light at 308 nm can vaporise thrombus, suppress platelet aggregation, and, unlike other thrombectomy devices, ablates the underlying plaque. AIM: To evaluate both safety and efficacy of laser ablation in patients presenting with Acute Myocardial Infarction (AMI) complicated by persistent thrombotic occlusion. METHODS: From May 2003 to October 2006, we enrolled 66 AMI patients (age 59+/-11 years; 57 men) presenting complete thrombotic occlusion of the infarct related vessel. All patients were treated with laser. Primary acute angiographic end-points was corrected TIMI frame count. Secondary echocardiographic end-point was left ventricular remodeling defined as an increase in end-diastolic volume >/=20% 6 months after infarction. Tertiary clinical endpoint was event-free survival at 6 months follow-up. RESULTS: There were no intra-procedural death or coronary perforation. One primary angiographic failure was observed during lasing. Major dissection occurred in 1 (1.5%) and distal embolization in 4 patients (6%). Corrected TIMI frame count was 100 at baseline, 29+/-0.6 after lasing and 22+/-3 after stenting. At 6-months follow-up, left ventricular remodeling occurred in 8% patients. Event-free survival was 95% at 6-months follow-up. CONCLUSION: Laser angioplasty is feasible, safe and effective for the challenging treatment of patients with AMI and thrombus-laden lesions. The acute effects on coronary epicardial and myocardial reperfusion are excellent.


Subject(s)
Angioplasty, Balloon, Laser-Assisted , Coronary Thrombosis/surgery , Myocardial Infarction/surgery , Coronary Angiography , Coronary Thrombosis/complications , Coronary Thrombosis/diagnostic imaging , Echocardiography , Feasibility Studies , Female , Humans , Male , Middle Aged , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Statistics, Nonparametric , Survival Analysis , Treatment Outcome
2.
Int J Cardiol ; 113(2): 283-4, 2006 Nov 10.
Article in English | MEDLINE | ID: mdl-16330116

ABSTRACT

BACKGROUND: Ionising radiation carries an oncogenic risk which is linearly related to the dose. An estimation of the effective dose can be obtained from the measurements of the dose-area product (DAP), which is a measure of stochastic risk and a potential quality indicator. AIM: To assess radiation exposure of patients in a large volume cardiac cath-lab. METHODS: A retrospective analysis of adult cardiac and peripheral percutaneous procedures (April to December 2004) was carried out to determine the DAP and estimated risk of malignancy. We identified 6 groups: Group 1 (n=100, coronary angiography and ventriculography); Group 2 (n=50, carotid stenting); Group 3 (n=50, aortography+coronary angiography+ventriculography); Group 4 (n=100, inferior extremities angiography+predilatation and stenting); Group 5 (n=100, coronary angiography+ventriculography+direct coronary stenting); Group 6 (n=100, coronary angiography+ventriculography+coronary predilation and stenting). Dose-area product meter attached on the X-ray unit was used for the estimation of the radiation dose received by the patient during the procedures. RESULTS: DAP values (mean+/-S.D.) ranged from 41+/-30 Gy cm2 in Group 1 (lowest) to 118+/-89 Gy cm2 in Group 6 (highest). Within each group, individual radiation exposure varies substantially: from 11 to 200 Gy cm2 in Group 1, and from 30 to 733 Gy cm2 in Group 6 patients. Average exposure in a Group 6 patient corresponds to a risk of mortality from a malignancy of about 1 in 1000. CONCLUSION: The radiation dose varies substantially across different types of procedures and up to tenfold within the same procedure. The enhanced knowledge of radiation dose might help the cardiologist to implement radiation sparing procedures eventually minimizing patient and operator radiation hazards in invasive cardiology.


Subject(s)
Aortography/adverse effects , Cardiac Catheterization , Catheterization, Peripheral , Coronary Angiography/adverse effects , Neoplasms, Radiation-Induced/etiology , Radionuclide Ventriculography/adverse effects , Adult , Aortography/methods , Coronary Angiography/methods , Dose-Response Relationship, Radiation , Humans , Incidence , Neoplasms, Radiation-Induced/epidemiology , Radionuclide Ventriculography/methods , Retrospective Studies , Risk Factors
3.
G Ital Cardiol ; 28(10): 1138-42; discussion 1143, 1998 Oct.
Article in Italian | MEDLINE | ID: mdl-9834866

ABSTRACT

Left main angioplasty is considered a very high-risk procedure and consequently, surgical treatment remains the first choice for left main critical disease. Recently, the advent of new devices such as directional atherectomy, rotablator atherectomy and stent implantation have modified this point of view. In fact, in selected groups of patients for whom CABG is not suitable, left main percutaneous angioplasty can be performed with stent implantation, yielding good final results with a residual stenosis less than 20-30% and a long-term survival comparable to surgery. In conclusion, in some selected cases left main angioplasty, also if unprotected, can be performed safely with satisfactory results.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/therapy , Stents , Aged , Coronary Disease/pathology , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...