Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Wien Klin Wochenschr ; 132(23-24): 782-800, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33259003

ABSTRACT

The enormous progress made in recent years in the field of information and communication technology and also in sensor and computer technology has affected numerous fields of medicine and is capable of inducing even radical changes in diagnostic and therapeutic processes. This is particularly true for cardiology, where, for example, telemetric monitoring of cardiac and circulatory functions has been in use for many years. Nevertheless, broad application of newer telemedical processes has not yet been achieved to the extent one would expect from the encouraging results of numerous clinical studies in this field and the state of the art of the underlying technology. In the present paper, the Working Group on Rhythmology of the Austrian Cardiological Society aims to provoke a critical discussion of the digital change in cardiology and to make recommendations for the implementation of those telemedical processes that have been shown to exert positive effects on a wide variety of medical and economic parameters. The greatest benefit of telecardiological applications is certainly to be found in the long-term care of patients with chronic cardiovascular diseases. Accordingly, follow-up care of patients with cardiological rhythm implants, management of chronic heart failure and secondary prevention following an acute cardiac event during rehabilitation are currently the most important fields of application. Telemedicine is intended to enable high-quality and cost-efficient care for an increasing number of patients, whose care poses one of the greatest challenges to our healthcare system. Not least of all, telemedicine should make a decisive contribution to improving the quality of life of this segment of the population by favorably influencing mortality, morbidity and hospitalization as well as the patient's contribution to treatment.


Subject(s)
Cardiology , Heart Failure , Telemedicine , Austria , Humans , Quality of Life
2.
Clin Cardiol ; 43(10): 1084-1092, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32794309

ABSTRACT

Within the last decade, implantable cardioverter-defibrillator (ICD) systems with non-transvenous leads were developed in order to minimize complications related to the cardiovascular position of transvenous ICD leads. This national expert consensus gives an overview of potential indications for the implantation of non-transvenous ICD systems, and provides specific recommendations for implantation, follow-up, and complication management in patients with subcutaneous ICD. Regarding particular issues like the necessity for shock efficacy testing, or the clinical outcome as compared to transvenous ICD, randomized data are expected in the near future.


Subject(s)
Consensus , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Humans
3.
Eur J Intern Med ; 48: 64-68, 2018 02.
Article in English | MEDLINE | ID: mdl-28978409

ABSTRACT

BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICD) are an innovative and less invasive alternative to transvenous ICD (TV-ICD) in selected patients. We aimed to investigate the underlying diseases and the specific indications for implanting S-ICD in clinical practice, as well as the prevalence of shock delivery and complications. METHODS AND RESULTS: From December 2012, data of 236 patients (30,5% female; age 48,6±16,8years) were gathered from 12 centres in Austria. Follow-up data over a period of 1,7±1,1years were available for 231 patients (in total 359,2 patient-years). Predominant underlying diseases were ischemic cardiomyopathy (iCMP; 32,0%), idiopathic ventricular fibrillation (22,6%) and dilated cardiomyopathy (dCMP; 17,3%). The most frequent indications for implantation were sudden cardiac death survival (27,4%), primary prevention for iCMP (23,9%) and for dCMP (12,8%), and previous explantation of TV-ICD (12,4%). Appropriate shocks were documented in 16 patients (6,9%), iCMP being the predominant underlying disease. Arrhythmia conversion was successful in all patients, efficacy of the first shock was 96%. Inappropriate shock rate was 5,2%, predominantly caused by oversensing of T wave or artefacts. A device upgrade to an ICD system with pacing function was necessary in <1%. Clinical complications needing surgical revision occurred in 8 patients (3,5%). CONCLUSIONS: S-ICD were mostly implanted for primary prevention, one fourth of our cases were sudden death survivors. Clinical and functional complication rate was relatively low. In conclusion, S-ICD is a safe and efficient alternative in a larger population of ICD candidates, when no cardiac pacing is needed. EC-number: C-136-17.


Subject(s)
Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Equipment Failure/statistics & numerical data , Ventricular Fibrillation/therapy , Adult , Aged , Austria/epidemiology , Female , Humans , Male , Middle Aged , Primary Prevention , Registries , Retrospective Studies , Secondary Prevention , Treatment Outcome , Ventricular Fibrillation/etiology
4.
Eur Heart J ; 30(10): 1237-44, 2009 May.
Article in English | MEDLINE | ID: mdl-19264750

ABSTRACT

AIMS: The aim of this study was to investigate the 12-month incidence, predictive factors, and prognosis of sustained ventricular tachycardia (VT) in chronic heart failure patients implanted with biventricular pacemakers without a back-up defibrillator (CRT-P), assessed by continuous intracardiac ventricular electrograms. METHODS AND RESULTS: The Mona Lisa study, a prospective, multicentre, cohort study, designed to determine the incidence of sustained VT and its prognostic impact in CRT-P recipients within the year after implant enrolled 198 patients with moderate or severe chronic heart failure, despite optimal pharmacological therapy. An independent committee reviewed the data from all arrhythmic episodes as well as causes of death according to predefined criteria. During a mean follow-up of 9.8 +/- 3.1 months after implantation, 8 patients experienced at least one episode of sustained VT [4.3%; 95% confidence interval (CI), 1.1-7.5] and 21 deaths occurred, giving a 12-month mortality rate of 11.7% (95% CI, 6.4-16.9). The presence of sustained VT was associated with a high risk of sudden cardiac death (SCD) and the lowest 12-month overall survival (P < 0.0001). CONCLUSION: The incidence of sustained VT remains relatively low in the first year after CRT-P implantation, but when present appears closely associated with short-term adverse outcomes, especially SCD. This emphasizes the possible value of remote monitoring to detect high-risk patients for urgent upgrading.


Subject(s)
Death, Sudden, Cardiac/epidemiology , Heart Failure/therapy , Pacemaker, Artificial , Tachycardia, Ventricular/epidemiology , Aged , Aged, 80 and over , Cardiac Pacing, Artificial/adverse effects , Cause of Death , Electrophysiologic Techniques, Cardiac/methods , Epidemiologic Methods , Female , Heart Failure/complications , Heart Failure/mortality , Humans , Male , Middle Aged , Prognosis , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/mortality
SELECTION OF CITATIONS
SEARCH DETAIL
...