1.
Biomed Res Int ; 2018: 5748281, 2018.
Article in English | MEDLINE | ID: mdl-29511685

ABSTRACT

The quality of images obtained from cone-beam computed tomography (CBCT) is important in diagnosis and treatment planning for dental and maxillofacial applications. However, X-ray scattering inside a human head is one of the main factors that cause a drop in image quality, especially in the CBCT system with a wide-angle cone-beam X-ray source and a large area detector. In this study, the X-ray scattering distribution within a standard head phantom was estimated using the Monte Carlo method based on Geant4. Due to small variation of low-frequency scattering signals, the scattering signals from the head phantom can be represented as the simple predetermined scattering signals from a patient's head and subtracted the projection data for scatter reduction. The results showed higher contrast and less cupping artifacts on the reconstructed images of the head phantom and real patients. Furthermore, the same simulated scattering signals can also be applied to process with higher-resolution projection data.


Subject(s)
Cone-Beam Computed Tomography , Head/diagnostic imaging , Maxillofacial Abnormalities/diagnostic imaging , Scattering, Radiation , Algorithms , Humans , Image Processing, Computer-Assisted , Maxillofacial Abnormalities/physiopathology , Monte Carlo Method , Phantoms, Imaging
2.
Biomed Res Int ; 2016: 3262795, 2016.
Article in English | MEDLINE | ID: mdl-27022608

ABSTRACT

Soft tissue images from portable cone beam computed tomography (CBCT) scanners can be used for diagnosis and detection of tumor, cancer, intracerebral hemorrhage, and so forth. Due to large field of view, X-ray scattering which is the main cause of artifacts degrades image quality, such as cupping artifacts, CT number inaccuracy, and low contrast, especially on soft tissue images. In this work, we propose the X-ray scatter correction method for improving soft tissue images. The X-ray scatter correction scheme to estimate X-ray scatter signals is based on the deconvolution technique using the maximum likelihood estimation maximization (MLEM) method. The scatter kernels are obtained by simulating the PMMA sheet on the Monte Carlo simulation (MCS) software. In the experiment, we used the QRM phantom to quantitatively compare with fan-beam CT (FBCT) data in terms of CT number values, contrast to noise ratio, cupping artifacts, and low contrast detectability. Moreover, the PH3 angiography phantom was also used to mimic human soft tissues in the brain. The reconstructed images with our proposed scatter correction show significant improvement on image quality. Thus the proposed scatter correction technique has high potential to detect soft tissues in the brain.


Subject(s)
Brain/diagnostic imaging , Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Models, Theoretical , X-Ray Diffraction/methods , Cone-Beam Computed Tomography/instrumentation , Humans , Phantoms, Imaging , Signal-To-Noise Ratio