1.
J Colloid Interface Sci ; 501: 77-85, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28437700

ABSTRACT

Amalgamation of noble metal nanomaterials on graphene flakes potentially paves one way to improve their physicochemical properties. This paper deals with the simultaneous electrochemical deposition of gold and palladium nanoparticles on graphene flakes (Au/PdNPs-GRF) for the sensitive determination of caffeic acid (CA). The physiochemical properties of the prepared Au/PdNPs-GRF was characterized by using numerous analytical techniques such as scanning electron microscopy, electron dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, X-ray powder diffraction, Raman spectroscopy and electrochemical impedance spectroscopy. The enhanced electrochemical determination of CA at Au/PdNPs deposition on GRF were studied by using cyclic voltammetry and differential pulse voltammetry. In results, Au/PdNPs-GRF electrode exhibited an excellent electrocatalytic activity towards CA with wide linear range and low limit of detection of 0.03-938.97µM and 6nM, respectively. Eventually, the Au/PdNPs-GRF was found as a selective and stable active material for the sensing of CA. In addition, the proposed sensor showed the adequate results in real sample analysis.


Subject(s)
Caffeic Acids/analysis , Electrochemical Techniques/methods , Gold/chemistry , Graphite/chemistry , Metal Nanoparticles/chemistry , Palladium/chemistry , Wine/analysis , Catalysis , Limit of Detection
2.
Carbohydr Polym ; 151: 401-407, 2016 Oct 20.
Article in English | MEDLINE | ID: mdl-27474582

ABSTRACT

The accurate detection of dopamine (DA) levels in biological samples such as human serum and urine are essential indicators in medical diagnostics. In this work, we describe the preparation of chitosan (CS) biopolymer grafted graphite (GR) composite for the sensitive and lower potential detection of DA in its sub micromolar levels. The composite modified electrode has been used for the detection of DA in biological samples such as human serum and urine. The GR-CS composite modified electrode shows an enhanced oxidation peak current response and low oxidation potential for the detection of DA than that of electrodes modified with bare, GR and CS discretely. Under optimum conditions, the fabricated GR-CS composite modified electrode shows the DPV response of DA in the linear response ranging from 0.03 to 20.06µM. The detection limit and sensitivity of the sensor were estimated as 0.0045µM and 6.06µA µM(-1)cm(-2), respectively.


Subject(s)
Chitosan/chemistry , Dopamine/blood , Dopamine/urine , Graphite/chemistry , Electrochemical Techniques , Electrodes , Humans
3.
J Colloid Interface Sci ; 475: 154-160, 2016 Aug 01.
Article in English | MEDLINE | ID: mdl-27163842

ABSTRACT

In this work, we report a selective electrochemical sensing of nitrobenzene (NB) using an alumina (γ-Al2O3) polished glassy carbon electrode (GCE) for the first time. The scanning electron microscopy studies confirm the presence of alumina particles on the GCE surface. X-ray photoelectron spectroscopy studies reveal that the utilized alumina is γ-Al2O3. The alumina polished GCE shows an enhanced sensitivity and lower overpotential toward the reduction of NB compared to unpolished GCE. The differential pulse voltammetry response was used for the determination of NB and it shows that the reduction peak current of NB is linearly proportional to the concentrations of NB ranging from 0.5 to 145.5µM. The limit of detection is found to be 0.15µM based on 3σ. The fabricated electrode exhibits its appropriate selectivity towards NB in the presence of a range of nitro compounds and metal ions. The good practicality of the sensor in various water samples reveals that it can be a promising electrode material for practical applications. In addition, the proposed NB sensor is simple and cost effective one when compared with previously reported NB sensors in the literature.