Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 94(3): 033512, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-37012776

ABSTRACT

Filamentary structures, also known as blobs, are a prominent feature of turbulence and transport at the edge of magnetically confined plasmas. They cause cross-field particle and energy transport and are, therefore, of interest in tokamak physics and, more generally, nuclear fusion research. Several experimental techniques have been developed to study their properties. Among these, measurements are routinely performed with stationary probes, passive imaging, and, in more recent years, Gas Puff Imaging (GPI). In this work, we present different analysis techniques developed and used on 2D data from the suite of GPI diagnostics in the Tokamak à Configuration Variable, featuring different temporal and spatial resolutions. Although specifically developed to be used on GPI data, these techniques can be employed to analyze 2D turbulence data presenting intermittent, coherent structures. We focus on size, velocity, and appearance frequency evaluation with, among other methods, conditional averaging sampling, individual structure tracking, and a recently developed machine learning algorithm. We describe in detail the implementation of these techniques, compare them against each other, and comment on the scenarios to which these techniques are best applied and on the requirements that the data must fulfill in order to yield meaningful results.

2.
Rev Sci Instrum ; 93(12): 123504, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36586925

ABSTRACT

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

3.
Rev Sci Instrum ; 92(4): 043547, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243470

ABSTRACT

A detailed description of the construction and commissioning of the fast-moving reciprocating divertor Langmuir probe array on the Tokamak à Configuration Variable (TCV) is presented. A horizontal array of 24 Langmuir probes (12 Mach probes) combined with a fast vertical movement provides unprecedented two-dimensional measurements of the plasma properties across the entire divertor outer leg volume and up to the X-point. The L-shape probe arm has to be very compact to minimize plasma perturbations and, at the same time, has to house 24 coaxial transmission lines, withstand time-averaged heat fluxes of up to ≈30 MW/m2 and accelerations of up to 8 g, and be resilient to violent plasma disruptions. For the fast vertical motion of the probe arm, extending up to 38 cm into the TCV vacuum vessel, an assembly with a precise and powerful linear electric motor (up to 4000 N of force) was mounted in a 4 m high structure within the limited space below the TCV. The diagnostic has already performed measurements in ≈200 plasma discharges and has been hit by ≈20 disruptions without suffering any critical damage. The measurements are qualitatively and quantitatively consistent with other reference diagnostics, such as upstream electron Thomson scattering and downstream wall-embedded Langmuir probes, and are used extensively on the TCV for experimental divertor studies and for comparisons with edge transport and turbulence code results.

4.
Nat Commun ; 12(1): 1105, 2021 Feb 17.
Article in English | MEDLINE | ID: mdl-33597525

ABSTRACT

In magnetic confinement thermonuclear fusion the exhaust of heat and particles from the core remains a major challenge. Heat and particles leaving the core are transported via open magnetic field lines to a region of the reactor wall, called the divertor. Unabated, the heat and particle fluxes may become intolerable and damage the divertor. Controlled 'plasma detachment', a regime characterized by both a large reduction in plasma pressure and temperature at the divertor target, is required to reduce fluxes onto the divertor. Here we report a systematic approach towards achieving this critical need through feedback control of impurity emission front locations and its experimental demonstration. Our approach comprises a combination of real-time plasma diagnostic utilization, dynamic characterization of the plasma in proximity to the divertor, and efficient, reliable offline feedback controller design.

5.
Rev Sci Instrum ; 90(8): 083502, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31472647

ABSTRACT

A detailed description of the Langmuir probe electronics upgrade for TCV (Tokamak à Configuration Variable) is presented. The number of amplifiers and corresponding electronics has been increased from 48 to 120 in order to simultaneously connect all of the 114 Langmuir probes currently mounted in the TCV divertor and main-wall tiles. Another set of 108 amplifiers is ready to be installed in order to connect 80 new probes, built in the frame of the TCV divertor upgrade. Technical details of the amplifier circuitry are discussed as well as improvements over the first generation of amplifiers developed at SPC (formerly CRPP) in 1993/1994 and over the second generation developed in 2012/2013. While the new amplifiers have been operated successfully for over a year, it was found that their silicon power transistors can be damaged during some off-normal plasma events. Possible solutions are discussed.

6.
Rev Sci Instrum ; 89(10): 103503, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399774

ABSTRACT

The Multi-Spectral Imaging system is a new diagnostic that captures simultaneous spectrally filtered images from a common line of sight while maintaining a large étendue and high throughput. Imaging several atomic line intensities simultaneously may enable numerous measurement techniques. By making a novel modification of a polychromator layout, the MSI sequentially filters and focuses images onto commercial CMOS cameras while exhibiting minimal vignetting and aberrations. A four-wavelength system was initially installed and tested on Alcator C-Mod and subsequently moved to TCV. The images are absolutely calibrated and spatially registered enabling 2D mappings of atomic line ratios and absolute line intensities. The spectral transmission of the optical system was calibrated using an integrating sphere of known radiance. The images are inverted by cross-referencing points on TCV with a computer-aided design (CAD) model.


Subject(s)
Diagnostic Imaging/instrumentation , Calibration , Spectrum Analysis
7.
Rev Sci Instrum ; 89(5): 053502, 2018 May.
Article in English | MEDLINE | ID: mdl-29864827

ABSTRACT

This paper presents the current wall-embedded Langmuir probe system installed on the Tokamak à Configuration Variable (TCV), as well as the analysis tool chain used to interpret the current-voltage characteristic obtained when the probes are operated in swept-bias conditions. The analysis is based on a four-parameter fit combined with a minimum temperature approach. In order to reduce the effect of plasma fluctuations and measurement noise, several current-voltage characteristics are usually averaged before proceeding to the fitting. The impact of this procedure on the results is investigated, as well as the possible role of finite resistances in the circuitry, which could lead to an overestimation of the temperature. We study the application of the procedure in a specific regime, the plasma detachment, where results from other diagnostics indicate that the electron temperature derived from the Langmuir probes might be overestimated. To address this issue, we explore other fitting models and, in particular, an extension of the asymmetric double probe fit, which features effects of sheath expansion. We show that these models yield lower temperatures (up to approximately 60%) than the standard analysis in detached conditions, particularly for a temperature peak observed near the plasma strike point, but a discrepancy with other measurements remains. We explore a possible explanation for this observation, the presence of a fast electron population, and assess how robust the different methods are in such conditions.

8.
Phys Rev Lett ; 116(10): 105001, 2016 Mar 11.
Article in English | MEDLINE | ID: mdl-27015485

ABSTRACT

Plasma blob dynamics on the high-field side in the proximity of a magnetic field null (X point) is investigated in TORPEX. A significant acceleration of the blobs towards the X point is observed. Close to the X point the blobs break apart. The E×B drifts associated with the blobs are measured, isolating the background drift component from the fluctuating contribution of the blob internal potential dipole. The time evolution of the latter is consistent with the fast blob dynamics. An analytical model based on charge conservation is derived for the potential dipole, including ion polarization, diamagnetic, and parallel currents. In the vicinity of the X point, a crucial role in determining the blob motion is played by the decrease of the poloidal magnetic field intensity. This variation increases the connection length that short circuits the potential dipole of the blob. Good quantitative agreement is found between the model and the experimental data in the initial accelerating phase of the blob dynamics.

9.
Phys Rev Lett ; 112(11): 115001, 2014 Mar 21.
Article in English | MEDLINE | ID: mdl-24702380

ABSTRACT

With fusion device performance hinging on the edge pedestal pressure, it is imperative to experimentally understand the physical mechanism dictating the pedestal characteristics and to validate and improve pedestal predictive models. This Letter reports direct evidence of density and magnetic fluctuations showing the stiff onset of an edge instability leading to the saturation of the pedestal on the Alcator C-Mod tokamak. Edge stability analyses indicate that the pedestal is unstable to both ballooning mode and kinetic ballooning mode in agreement with observations.

10.
Rev Sci Instrum ; 84(9): 093505, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24094058

ABSTRACT

A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

11.
Phys Rev Lett ; 108(6): 065005, 2012 Feb 10.
Article in English | MEDLINE | ID: mdl-22401080

ABSTRACT

Blob control by creating convective cells using biased electrodes is demonstrated in simple magnetized toroidal plasmas. A two-dimensional array of electrodes is installed on a metal limiter to obtain different biasing schemes. Detailed two-dimensional measurements across the magnetic field reveal the formation of a convective cell, which shows a high degree of uniformity along the magnetic field. Depending on the biasing scheme, radial and vertical blob velocities can be varied significantly. A high level of cross-field currents limits the achievable potential variations to values well below the applied bias voltage. Furthermore, the strongest potential variations are not induced along the biased flux tube, but at a position shifted in the direction of plasma flows.

12.
Phys Rev Lett ; 106(24): 245001, 2011 Jun 17.
Article in English | MEDLINE | ID: mdl-21770576

ABSTRACT

In simple magnetized toroidal plasmas, field-aligned blobs originate from ideal interchange waves and propagate radially outward under the effect of ∇B and curvature induced E×B drifts. We report on the first experimental two-dimensional measurements of the field-aligned current associated with blobs, whose ends terminate on a conducting limiter. A dipolar structure of the current density is measured, which originates from ∇B and curvature induced polarization of the blob and is consistent with sheath boundary conditions. The dipole is strongly asymmetric due to the nonlinear dependence of the current density at the sheath edge upon the floating potential. Furthermore, we directly demonstrate the existence of two regimes, in which parallel currents to the sheath do or do not significantly damp charge separation and thus blob radial velocity.

13.
Rev Sci Instrum ; 82(1): 013504, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21280828

ABSTRACT

The triple probe method to obtain local, time-resolved measurements of density, electron temperature and plasma potential is investigated in detail. The difficulties in obtaining reliable measurements with this technique are discussed and overcome. These include phase delay errors, ion sheath expansion and limited bandwidth due to stray capacitance to ground. In particular, a relatively simple electronic circuit is described to strongly reduce stray capacitance. Measurements with the triple probe are presented in a plasma characterized by interchange-driven turbulence in the TORPEX device. The measured time-averaged and time-dependent, conditionally averaged parameters are cross-checked with other Langmuir probe based techniques, and show good agreement. Triple probe measurements show that electron temperature fluctuations are sufficiently large, such that the identification of plasma potential fluctuations with fluctuations of the floating potential is not a good approximation. Over a large radial region, the time-averaged fluctuation-induced particle flux can, however, be deduced from floating potential only. This is because the phase shift between density and electron temperature is close to zero there and temperature fluctuations do not give rise to a net radial particle transport.

14.
Phys Rev Lett ; 103(6): 065001, 2009 Aug 07.
Article in English | MEDLINE | ID: mdl-19792574

ABSTRACT

The radial propagation of blobs generated from plasma instabilities is investigated in an open magnetic field line configuration. Blob cross-field velocities and sizes are obtained from internal probe measurements using pattern recognition. By varying the ion mass, the normalized vertical blob scale a[over] is scanned from a[over] < 1 to a[over] > 1. An analytical expression for the blob velocity including cross-field ion polarization currents, parallel currents to the sheath, and ion-neutral collisions is derived and shows good quantitative agreement with the experimental data. In agreement with previous theoretical studies, this scaling shows that, for a[over] < 1, the blob velocity is limited by cross-field ion polarization currents, while for a[over] > 1 it is limited by parallel currents to the sheath.

15.
Phys Rev Lett ; 101(11): 115005, 2008 Sep 12.
Article in English | MEDLINE | ID: mdl-18851292

ABSTRACT

The global dynamic of plasma blobs in a shear flow is investigated in a simple magnetized torus using the spatial Fourier harmonics (k-space) framework. Direct experimental evidence of a linear drift in k space of the density fluctuation energy synchronized with blob events is presented. During this drift, an increase of the fluctuation energy and a production of the kinetic energy associated with blobs are observed. The energy source of the blob is analyzed using an advection-dissipation-type equation that includes blob-flow exchange energy, linear drift in k space, nonlinear processes, and viscous dissipations. We show that blobs tap their energy from the dominant ExB vertical background flow during the linear drift stage. The exchange of energy is unidirectional as there is no evidence that blobs return energy to the flow.

16.
Phys Rev Lett ; 101(4): 045001, 2008 Jul 25.
Article in English | MEDLINE | ID: mdl-18764334

ABSTRACT

The mechanisms for anomalous transport across the magnetic field are investigated in a toroidal magnetized plasma. The role of plasma instabilities and macroscopic density structures (blobs) is discussed. Examples from a scenario with open magnetic field lines are shown. A transition from a main plasma region into a loss region is reproduced. In the main plasma, which includes particle and heat source locations, the transport is dominated by the fluctuation-induced particle and heat flux associated with a plasma instability. On the low-field side, the cross-field transport is ascribed to the intermittent ejection of macroscopic blobs propagating toward the outer wall. It is shown that instabilities and blobs represent fundamentally different mechanisms for cross-field transport.

17.
Phys Rev Lett ; 100(5): 055004, 2008 Feb 08.
Article in English | MEDLINE | ID: mdl-18352382

ABSTRACT

The mechanism for blob generation in a toroidal magnetized plasma is investigated using time-resolved measurements of two-dimensional structures of electron density, temperature, and plasma potential. The blobs are observed to form from a radially elongated structure that is sheared off by the E x B flow. The structure is generated by an interchange wave that increases in amplitude and extends radially in response to a decrease of the radial pressure scale length. The dependence of the blob amplitude upon the pressure radial scale length is discussed.

18.
Onderstepoort J Vet Res ; 42(1): 33-9, 1975 Mar.
Article in English | MEDLINE | ID: mdl-1237841

ABSTRACT

Ixodes (Afrixodes) drakensbergensis n. sp., is described from females, males, nymphs and larvae collected on a drag at Giant's Castle Nature Reserve, Natal, Republic of South Africa; it was also taken from an eland in the same area and from goats and a cow in the adjacent Tank Area 118. The occurrence of I. (A.) drakensbergensis on domestic animals suggests that it may be of economic importance in this area. Information is provided to separate the new species from other closely related Ixodes species that occur or may occur in this region.


Subject(s)
Artiodactyla/parasitology , Cattle Diseases/parasitology , Goats/parasitology , Tick Infestations/veterinary , Ticks/classification , Animals , Cattle , Female , Larva/anatomy & histology , Male , Nymph/anatomy & histology , South Africa , Tick Infestations/epidemiology , Tick Infestations/parasitology
SELECTION OF CITATIONS
SEARCH DETAIL
...