Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 55(5): 1395-411, 2010 Mar 07.
Article in English | MEDLINE | ID: mdl-20150685

ABSTRACT

Flow patterns may affect the potential of thrombus formation following plaque rupture. Computational fluid dynamics (CFD) were employed to assess hemodynamic conditions, and particularly flow recirculation and vortex formation in reconstructed arterial models associated with ST-elevation myocardial infraction (STEMI) or stable coronary stenosis (SCS) in the left anterior descending coronary artery (LAD). Results indicate that in the arterial models associated with STEMI, a 50% diameter stenosis immediately before or after a bifurcation creates a recirculation zone and vortex formation at the orifice of the bifurcation branch, for most of the cardiac cycle, thus allowing the creation of stagnating flow. These flow patterns are not seen in the SCS model with an identical stenosis. Post-stenotic recirculation in the presence of a 90% stenosis was evident at both the STEMI and SCS models. The presence of 90% diameter stenosis resulted in flow reduction in the LAD of 51.5% and 35.9% in the STEMI models and 37.6% in the SCS model, for a 10 mmHg pressure drop. CFD simulations in a reconstructed model of stenotic LAD segments indicate that specific anatomic characteristics create zones of vortices and flow recirculation that promote thrombus formation and potentially myocardial infarction.


Subject(s)
Coronary Circulation , Coronary Stenosis/physiopathology , Hemodynamics , Models, Biological , Computer Simulation , Coronary Occlusion/etiology , Coronary Stenosis/complications , Coronary Stenosis/pathology , Humans , Models, Anatomic , Myocardial Infarction/etiology
2.
Phys Med Biol ; 53(18): 4875-92, 2008 Sep 21.
Article in English | MEDLINE | ID: mdl-18711245

ABSTRACT

This study aimed at investigating the effect of myocardial motion on pulsating blood flow distribution of the left anterior descending coronary artery in the presence of atheromatous stenosis. The moving 3D arterial tree geometry has been obtained from conventional x-ray angiograms obtained during the heart cycle and includes a number of major branches. The geometry reconstruction model has been validated against projection data from a virtual phantom arterial tree as well as with CT-based reconstruction data for the same patient investigated. Reconstructions have been obtained for a number of temporal points while linear interpolation has been used for all intermediate instances. Blood has been considered as a non-Newtonian fluid. Results have been obtained using the same pulse for the inlet blood flow rate but with fixed arterial tree geometry as well as under steady-state conditions corresponding to the mean flow rate. Predictions indicate that myocardial motion has only a minor effect on flow distribution within the arterial tree relative to the effect of the blood pressure pulse.


Subject(s)
Blood Flow Velocity/physiology , Coronary Circulation/physiology , Coronary Vessels/physiology , Heart/physiology , Models, Cardiovascular , Movement/physiology , Pulsatile Flow/physiology , Animals , Computer Simulation , Humans , Nonlinear Dynamics
3.
J Colloid Interface Sci ; 300(2): 673-87, 2006 Aug 15.
Article in English | MEDLINE | ID: mdl-16774763

ABSTRACT

The detachment of liquid droplets from porous material surfaces used with proton exchange membrane (PEM) fuel cells under the influence of a cross-flowing air is investigated computationally and experimentally. CCD images taken on a purpose-built transparent fuel cell have revealed that the water produced within the PEM is forming droplets on the surface of the gas-diffusion layer. These droplets are swept away if the velocity of the flowing air is above a critical value for a given droplet size. Static and dynamic contact angle measurements for three different carbon gas-diffusion layer materials obtained inside a transparent air-channel test model have been used as input to the numerical model; the latter is based on a Navier-Stokes equations flow solver incorporating the volume of fluid (VOF) two-phase flow methodology. Variable contact angle values around the gas-liquid-solid contact-line as well as their dynamic change during the droplet shape deformation process, have allowed estimation of the adhesion force between the liquid droplet and the solid surface and successful prediction of the separation line at which droplets loose their contact from the solid surface under the influence of the air stream flowing around them. Parametric studies highlight the relevant importance of various factors affecting the detachment of the liquid droplets from the solid surface.

SELECTION OF CITATIONS
SEARCH DETAIL
...