Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Orthopedics ; 39(3 Suppl): S50-5, 2016 May.
Article in English | MEDLINE | ID: mdl-27219729

ABSTRACT

The aim of the study was to examine the effects of rotational component alignment on outcome after total knee arthroplasty (TKA) with a minimum follow-up of 5 years. For this study, 96 patients were available for follow-up at a mean of 5.7 years after TKA. Computed tomography scans were available in 55 patients. Outcome (Oxford Knee Score [KSS], Knee Injury and Osteoarthritis Outcome Score [KOOS], 36-item Short Form Health Survey) was correlated with postoperative femoral and tibial component malrotation or femorotibial rotational alignment mismatch. Results showed that femoral or tibial component malrotation or femorotibial mismatch were present in 15.5%, 38.2%, and 29.1% of patients, respectively. Although femoral componoent malrotation was associated with significantly poorer, KSS and KOOS scores, outcome was comparable for patients with or without tibial component malrotation or femorotibial mismatch. In conclusion, both internal and external rotational femoral malalignment exceeding 3° is associated with significantly poorer subjective and objective outcome 5 to 7 years after TKA. Tibial component malrotation and femorotibial mismatch were more common, but did not significantly compromise outcome. [Orthopedics. 2016; 39(3):S50-S55.].


Subject(s)
Arthroplasty, Replacement, Knee , Bone Malalignment , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Aged , Bone Malalignment/etiology , Female , Femur/surgery , Follow-Up Studies , Humans , Male , Prosthesis Design , Retrospective Studies , Rotation , Tibia/surgery , Tomography, X-Ray Computed , Treatment Outcome
2.
Knee Surg Sports Traumatol Arthrosc ; 21(10): 2346-54, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23188500

ABSTRACT

PURPOSE: The aim of the present study was to assess the changes in rotational alignment introduced by total knee arthroplasty (TKA) and the reproducibility of pre- and postoperative CT measurements of rotational limb alignment. METHODS: For this purpose we analyzed data from 196 consecutive cruciate-retaining, fixed bearing Columbus TKA procedures. Both pre- and postoperative scans torsion difference CT scans were available for measurements in 89 cases. Using these CT scans the neck-malleolar angle (NMA), the femoral posterior condylar angle (fPCA), the tibial posterior condylar axis (tPCA) and the tibial torsion angle (TTA) were independently assessed by three raters. CT scans were re-evaluated 8 weeks later by the most experienced rater for assessment of intraobserver agreement. RESULTS: Measurements of all angles were prone to high standard deviations reflecting interindividual variability. Mean fPCA changed from 1.3° to 2.7° internal rotation preoperatively to 0.1°-1.9° internal rotation postoperatively. Based on a relative external rotation of the tibial base plate as compared to the preoperative situation, we found a relative internal rotation of the postoperative NMA and tibial torsion of 3°-5.4° and 6°-7.5°, respectively. Intra- and interobserver agreement was strong for all angles assessed (ICCs 0.7-1.0) except for fPCA (ICC 0.2-0.6). However, mean absolute measurement differences for fPCA were clinically acceptable (1.2°-2.6°). CONCLUSIONS: Reproducibility of CT rotational limb alignment measurements was found to be clinically acceptable. Rotational alignment of the femoral and even more so of the tibial component will ultimately affect the rotational alignment of the entire limb-at least when fixed bearings are used. LEVEL OF EVIDENCE: Diagnostic study, Level III.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Anteversion/surgery , Bone Retroversion/surgery , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Tomography, X-Ray Computed , Aged , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Bone Anteversion/complications , Bone Anteversion/diagnostic imaging , Bone Malalignment/diagnostic imaging , Bone Malalignment/etiology , Bone Malalignment/prevention & control , Bone Retroversion/complications , Bone Retroversion/diagnostic imaging , Female , Humans , Knee Joint/diagnostic imaging , Knee Joint/physiopathology , Knee Prosthesis , Male , Observer Variation , Osteoarthritis, Knee/complications , Osteoarthritis, Knee/diagnostic imaging , Postoperative Care , Postoperative Complications/diagnostic imaging , Postoperative Complications/prevention & control , Preoperative Care , Reproducibility of Results , Retrospective Studies , Rotation , Treatment Outcome
4.
Injury ; 39(8): 907-13, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18599058

ABSTRACT

From January 2003 and February 2006, 31 displaced acetabular fractures were treated by open reduction and internal fixation. The fractures were managed using a single approach, involving a straight lateral incision centered over the greater trochanter, trochanteric osteotomy and dislocation of the femoral head. The mean age of the patients was 48 (range 20-74 years) with a mean follow up 24 months (range from 20 to 42 months). Ten fractures were classified as simple, and 21 as complex fractures. The mean time to surgery was 4.5 days (range from 0 to 14 days). Mean operating time was 118 min (range 52-168). Five patients presented with posterior dislocation of the hip joint at the time of initial presentation. The trochanteric fragment was fixed with three 3.5mm cortical screws. Congruent reduction was achieved in all patients and all osteotomies healed within 5 months. Clinical evaluation was based on the modified Merle d'Aubigne and Postel scoring. Motor strength of abduction was evaluated according to the Medical Research Council grading. Clinical scoring was excellent to good in 24%. The strength of the abductors was grade 0/5 in a patient with Brooker's class IV heterotopic ossification, and 3/5 in the two patients with necrosis of the femoral head. There were five patients with grade 4/5 and the 5/5 in the rest. Complications included two segmental femoral head necrosis, one of them combined with necrosis of the weight bearing acetabular dome area. These patients required total hip replacement. Mild heterotopic ossification grade II was seen in one patient and significant (grade IV), in another patient. Two patients developed superficial wound infection over the trochanteric area and another two patients persistent pain due to irritation caused by the screws. One patient developed peroneal nerve palsy which resolved 3 months after the surgery. The trochanteric slide osteotomy can enhance the exposure of the whole acetabulum and the femoral head. This allows better evaluation of any osteochondral lesions, intra-articular bony fragments and fracture steps, providing a more accurate reduction and easier fixation of the acetabular fracture.


Subject(s)
Acetabulum/surgery , Femur/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Osteotomy/methods , Acetabulum/injuries , Adult , Aged , Female , Femur/injuries , Humans , Male , Middle Aged , Osteotomy/standards , Treatment Outcome
5.
Knee Surg Sports Traumatol Arthrosc ; 16(9): 876-83, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18592217

ABSTRACT

Massive and irreparable rotator cuff tears are a challenge for the orthopaedic surgeon. The purpose of this study was to report our experience with the treatment of massive and irreparable defects of the rotator cuff with a modified deltoid split transfer. Between 1996 and 2004, for all patients suffering from full-thickness tears of the rotator cuff (> 5 cm tears in diameter, involving two or more tendons) were operated with a modified deltoid split transfer. A total of 61 patients (39 females and 22 males; age 61.9: range 49-75 years) were operated. Duration of symptoms before surgery averaged 9.6 months (range 3.5-14 months). The patients were followed for an average of 46 months (range 24-64 months). The operation included an arthroscopic evaluation, acromioplasty with resection of the lateral clavicular end, resection of the acromioclavicular joint and where necessary biceps tenodesis. The cuff defect was repaired by transfer of half thickness anterior deltoid-flap (3 cm x 5 cm) into the defect. All patients were evaluated both preoperatively and postoperatively with regard to pain, ability to perform activities of daily life, range of motion, strength and satisfaction. The patients subjectively rated their results--49 (80%) excellent or good outcome, seven moderate and five poor. Preoperatively, the Constant amounted 33.5 +/- 7.74 points. At follow-up, the score significantly increased to 77.57 +/- 19.74 points. The acromiohumeral distance increased from 5.1 +/- 1.4 mm to 9.1 +/- 1.5 mm. Pain free flexion improved from an average 90 degrees to an average 165 degrees (P < 0.01), and abduction improved from an average 110 degrees to an average 160 degrees (P < 0.01). The mean external rotation increased from 40 degrees to 65 degrees (P < 0.01), and internal rotation increased from 50 degrees to 70 degrees (P = 0.06). In the MRI and ultrasound examination, all patients had intact flap, except the three patients with flap necrosis. There were eight complications--three haematomas, two superficial wound infections which did not influence the outcome, and three fibrotic transformation after an early aseptic necrosis of the deltoid flap, which were re-operated. This technique is easy to perform, and it is possible to obtain a satisfactory outcome after repair of massive tears of the rotator cuff. A substantial decrease of pain, increased stability, an increase range of motion and strength can be achieved, with proper rehabilitation.


Subject(s)
Arthroscopy , Rotator Cuff Injuries , Surgical Flaps , Tendon Transfer/methods , Aged , Cohort Studies , Female , Humans , Male , Middle Aged , Range of Motion, Articular , Retrospective Studies , Shoulder Pain/etiology , Shoulder Pain/pathology , Shoulder Pain/surgery , Tenodesis , Treatment Outcome
6.
Orthopedics ; 30(10 Suppl): S132-5, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17983115

ABSTRACT

Use of the OrthoPilot navigation system (B. Braun Aesculap, Tuttlingen, Germany) in navigated revision surgery allows for precise alignment of components, restoration of the joint line, balance of the gaps, and filling of the bony defects by facilitating selection of appropriate implant sizes and wedges. Our study results confirm these benefits through clinical and radiologic evaluation of the first 46 cases in our series in which the system was used. Continuous feedback from the system during surgery confirms that the surgeon is using proper technique. The OrthoPilot navigation system simplifies revision surgery and helps produce successful patient outcomes.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Surgery, Computer-Assisted/methods , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Prosthesis Failure , Reoperation/methods , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...