Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
3.
Am J Cardiol ; 118(8): 1217-1224, 2016 Oct 15.
Article in English | MEDLINE | ID: mdl-27586169

ABSTRACT

Super-response to cardiac resynchronization therapy (CRT) is associated with significant left ventricular (LV) reverse remodeling and improved clinical outcome. The study aimed to: (1) evaluate whether LV reverse remodeling remains sustained during long-term follow-up in super-responders and (2) analyze the association between the course of LV reverse remodeling and ventricular arrhythmias. Of all, primary prevention super-responders to CRT were selected. Super-response was defined as LV end-systolic volume reduction of ≥30% 6 months after device implantation. Cox regression analysis was performed to investigate the association of LV ejection fraction (LVEF) as time-dependent variable with implantable-cardioverter defibrillator (ICD) therapy and mortality. A total of 171 super-responders to CRT-defibrillator were included (mean age 67 ± 9 years; 66% men; 37% ischemic heart disease). Here of 129 patients received at least 1 echocardiographic evaluation after a median follow-up of 62 months (25th to 75th percentile, 38 to 87). LV end-diastolic volume, LV end-systolic volume, and LVEF after 6-month follow-up were comparable with those after 62-month follow-up (p = 0.90, p = 0.37, and p = 0.55, respectively). Changes in LVEF during follow-up in super-responders were independently associated with appropriate ICD therapy (hazard ratio 0.94, 95% CI 0.90 to 0.98; p = 0.005) and all-cause mortality (hazard ratio 0.95, 95% CI 0.91 to 1.00; p = 0.04). A 5% increase in LVEF was associated with a 1.37 times lower risk of appropriate ICD therapy and a 1.30 times lower risk of mortality. In conclusion, LV reverse remodeling in super-responders to CRT remains sustained during long-term follow-up. Changes in LVEF during follow-up were associated with mortality and ICD therapy.


Subject(s)
Cardiac Resynchronization Therapy/methods , Death, Sudden, Cardiac/prevention & control , Electric Countershock , Heart Failure/therapy , Stroke Volume , Ventricular Remodeling , Aged , Cause of Death , Death, Sudden, Cardiac/etiology , Defibrillators, Implantable , Echocardiography, Doppler, Color , Female , Heart Failure/complications , Heart Failure/diagnostic imaging , Heart Failure/mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mortality , Proportional Hazards Models
4.
Heart Rhythm ; 12(6): 1169-76, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25749138

ABSTRACT

BACKGROUND: Large randomized trials demonstrated the beneficial effect of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) treatments in selected patients. Data on long-term follow-up of patients outside the setting of clinical trials are scarce. OBJECTIVE: The aim of this study was to evaluate the long-term outcome of ICD and CRT-D recipients. METHODS: All patients who underwent ICD (n = 1729 [57%]) or CRT-D (n = 1326 [43%]) implantation at the Leiden University Medical Center since 1996 were evaluated. Follow-up visits were performed every 3-6 months, and events were registered. Cumulative incidence curves of device therapy and device-related complications were adjusted for the competing risk of all-cause mortality. RESULTS: After a median follow-up of 5.1 years (25th-75th percentile 3.1-7.8 years), 842 patients (28%) died. The cumulative incidence of all-cause mortality was 49% (95% confidence interval [CI] 45%-54%) in ICD recipients after 12 years of follow-up and 55% (95% CI 52%-58%) in CRT-D recipients after 8 years of follow-up. A total of 1081 patients (35%) received appropriate defibrillator therapy. The cumulative incidence of appropriate therapy in ICD patients was 58% (95% CI 54%-62%) after 12 years of follow-up and 39% (95% CI 35%-43%) in CRT-D patients after 8 years of follow-up. Twelve-year cumulative incidences of adverse events were 20% (95% CI 18%-22%) for inappropriate shock, 6% (95% CI 5%-8%) for device-related infection, and 17% (95% CI 14%-21%) for lead failure. CONCLUSION: After long-term follow-up of ICD (12 years) and CRT-D (8 years) recipients, 49% of ICD recipients and 55% of CRT-D recipients had died. Appropriate ICD therapy was received by the majority (58%) of ICD recipients and by almost 40% of CRT-D recipients.


Subject(s)
Cardiac Resynchronization Therapy Devices , Defibrillators, Implantable , Aged , Cardiac Resynchronization Therapy Devices/adverse effects , Defibrillators, Implantable/adverse effects , Device Removal , Female , Follow-Up Studies , Humans , Male , Middle Aged , Treatment Outcome
5.
J Am Soc Echocardiogr ; 28(4): 470-7, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25636367

ABSTRACT

BACKGROUND: Differences in arrhythmogenic substrate may explain the variable efficacy of implantable cardioverter-defibrillators (ICDs) in primary sudden cardiac death prevention over time after myocardial infarction (MI). Speckle-tracking echocardiography allows the assessment left ventricular (LV) dyssynchrony, which may reflect the electromechanical heterogeneity of myocardial tissue. The aim of the present study was to evaluate the relationship among LV dyssynchrony, age of MI, and their association with the risk for ventricular tachycardia (VT) after MI. METHODS: A total of 206 patients (median age, 67 years; 87% men) with prior MIs (median MI age, 6.2 years; interquartile range, 0.66-15 years) who underwent programmed electrical stimulation, speckle-tracking echocardiography, and ICD implantation were retrospectively evaluated. LV dyssynchrony was defined as the standard deviation of time to peak longitudinal systolic strain values using speckle-tracking strain echocardiography. LV scar burden was evaluated by the percentage of segments exhibiting scar (defined as an absolute longitudinal strain of magnitude < 4.5%). Patients were followed up for the occurrence of first monomorphic VT requiring ICD therapy (antitachycardia pacing or shock) for a median of 24 months. RESULTS: In total, 75 individuals experienced the primary end point of monomorphic VT. LV dyssynchrony was independently associated with the occurrence of VT at follow-up (hazard ratio per 10-msec increase, 1.12; 95% confidence interval, 1.07-1.18; P < .001), together with nonrevascularization of the infarct-related artery and VT inducibility. Patients with older (>180 months) MIs had a higher likelihood of VT inducibility (88% vs 63%, P = .003) and greater scar burden (14.7 ± 15.8% vs 10.7 ± 11.4%, P = .03) compared with patients with recent (<8 months) MIs. CONCLUSIONS: LV dyssynchrony is independently associated with the occurrence of VT after MI.


Subject(s)
Echocardiography/methods , Myocardial Infarction/diagnostic imaging , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/etiology , Ventricular Dysfunction, Left/diagnostic imaging , Aged , Elastic Modulus , Elasticity Imaging Techniques/methods , Female , Humans , Image Interpretation, Computer-Assisted/methods , Male , Myocardial Infarction/complications , Myocardial Infarction/physiopathology , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Stroke Volume , Tachycardia, Ventricular/physiopathology , Time Factors , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/physiopathology
6.
Eur J Heart Fail ; 16(10): 1104-11, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25138313

ABSTRACT

AIMS: Mortality and ventricular arrhythmias are reduced in patients responding to cardiac resynchronization therapy (CRT). This response is accompanied by improvement in LVEF, and some patients even outgrow original eligibility criteria for implantable cardioverter-defibrillator (ICD) implantation. It is however unclear if these patients still benefit from ICD treatment. The current study aimed to evaluate if the incidence of ICD therapy is related to the extent of CRT response. METHODS AND RESULTS: All patients who underwent primary prevention CRT-defibrillator implantation were included. They were divided into subgroups according to the reduction in LV end-systolic volume (LVESV) 6 months after implantation. Pre-defined subgroups were: negative responders (increased LVESV), non-responders (decreased LVESV 0-14%), responders (decreased LVESV 15-29%), and super-responders (decreased LVESV ≥30%). During a median follow-up of 57 months (25th-75th percentile 39-84), 512 patients were studied [101 (20%) negative responders, 101 (20%) non-responders, 149 (29%) responders, and 161 (31%) super-responders]. In the first year of follow-up super-responders received significantly less appropriate ICD therapy (3% vs. 12%; P < 0.001). The 5-year cumulative incidence of appropriate ICD therapy was 31% [95% confidence interval (CI) 19-43] in negative responders, 39% (95% CI 25-53) in non-responders, 34% (95% CI 25-43) in responders, and 27% (95% CI 18-35) in super-responders, respectively (p = 0.13). CONCLUSIONS: The extent of CRT response was associated with a parallel reduction of appropriate device therapy during the first year of follow-up. Thereafter, no association was observed. Furthermore, 23% of super-responders were treated for potentially life-threatening arrhythmias and benefit from ICD treatment.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable/adverse effects , Heart Failure , Tachycardia, Ventricular/prevention & control , Aged , Aged, 80 and over , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Female , Follow-Up Studies , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/therapy , Humans , Male , Middle Aged , Netherlands/epidemiology , Risk Assessment , Severity of Illness Index , Survival Analysis , Ventricular Remodeling
7.
Int J Cardiovasc Imaging ; 30(3): 549-58, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24500241

ABSTRACT

Accurate predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in hypertrophic cardiomyopathy (HCM) patients are lacking. Both left atrial volume index (LAVI) and global longitudinal strain (GLS) have been proposed as prognostic markers in HCM patients. The specific value of LAVI and GLS to predict appropriate ICD therapy in high-risk HCM patients was studied. LAVI and 2-dimensional speckle tracking-derived GLS were assessed in 92 HCM patients undergoing ICD implantation (69 % men, mean age 50 ± 14 years). During long-term follow-up, appropriate ICD therapies, defined as antitachycardia pacing and/or shock for ventricular arrhythmia, were recorded. Appropriate ICD therapy occurred in 21 patients (23 %) during a median follow-up of 4.7 (2.2-8.2) years. Multivariate analysis revealed LAVI (p = 0.03) and GLS (p = 0.04) to be independent predictors of appropriate ICD therapy. Both LAVI and GLS showed higher accuracy to predict appropriate ICD therapy compared to presence of ≥1 conventional sudden cardiac death (SCD) risk factor(s) [area under the curve 0.76 (95 % CI 0.65-0.87) and 0.65 (95 % CI 0.54-0.77) versus 0.52 (95 % CI 0.43-0.58) respectively, p < 0.001]. No patient with both LAVI <34 mL/m(2) and GLS <-14 % experienced appropriate ICD therapy. Assessment of both LAVI and GLS on top of conventional SCD risk factors provided incremental clinical predictive value for appropriate ICD therapy, as shown by likelihood ratio test (p < 0.001) and integrated discrimination improvement index (0.17, p < 0.001). LAVI and GLS provide high negative predictive value for appropriate ICD therapy in high-risk HCM patients. Additionally to conventional SCD risk factors, both parameters may be useful to optimize criteria and timing for ICD implantation in these patients.


Subject(s)
Cardiomyopathy, Hypertrophic/physiopathology , Cardiomyopathy, Hypertrophic/therapy , Defibrillators, Implantable , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Stroke Volume/physiology , Cardiomyopathy, Hypertrophic/diagnostic imaging , Female , Follow-Up Studies , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Risk Factors , Treatment Outcome , Ultrasonography
8.
Heart ; 100(12): 960-8, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24449717

ABSTRACT

BACKGROUND: Although the presence of an RV lead is a potential cause of tricuspid regurgitation (TR), the clinical impact of significant lead-induced TR is unknown. OBJECTIVE: To evaluate the effect of significant lead-induced TR on cardiac performance and long-term outcome after cardioverter-defibrillator (ICD) or pacemaker implantation. METHODS: A retrospective cohort of 239 ICD (n=191) or pacemaker (n=48) recipients (age 60±14 years, 77% male) from a tertiary care university hospital, with an echocardiographic evaluation before and within 1-1.5 years after device implantation were included. Significant lead-induced TR was defined as TR worsening, reaching a grade ≥2 at follow-up echocardiography. During long-term follow-up (median 58, IQR 35-76 months), all-cause mortality and heart failure related events were recorded. RESULTS: Before device implantation, most patients had TR grade 1 or 2 (64.0%) or no TR (33.9%), but after lead placement, significant TR was seen in 91 patients (38%). Changes in cardiac volumes and function at follow-up were similar between patients with and without significant lead-induced TR, except for larger RV diastolic area (17±6mm(2) vs 16±5mm(2), p=0.009), larger right atrial diameter (39±10 mm vs 36±8 mm, p<0.001) and higher pulmonary arterial pressures (41±15 mm Hg vs 33±10 mm Hg, p<0.001) in patients with significant lead-induced TR. Patients with significant lead-induced TR had worse long-term survival (HR=1.687, p=0.040) and/or more heart failure related events (HR=1.641, p=0.019). At multivariate analysis, significant lead-induced TR was independently associated with all-cause mortality (HR=1.749, p=0.047) together with age, LVEF and percentage RV pacing. CONCLUSIONS: Significant lead-induced TR is associated with poor long-term prognosis.


Subject(s)
Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Tricuspid Valve Insufficiency/etiology , Age Factors , Aged , Chi-Square Distribution , Female , Heart Failure/etiology , Heart Failure/physiopathology , Hospitals, University , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Prognosis , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Factors , Stroke Volume , Tertiary Care Centers , Time Factors , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/physiopathology , Ventricular Function, Left
9.
Am J Cardiol ; 113(6): 982-7, 2014 Mar 15.
Article in English | MEDLINE | ID: mdl-24462070

ABSTRACT

Cardiac resynchronization therapy (CRT) induces left ventricular (LV) reverse remodeling by synchronizing LV mechanical activation. We evaluated changes in segmental LV activation after CRT and related them to CRT response. A total of 292 patients with heart failure (65 ± 10 years, 77% men) treated with CRT underwent baseline echocardiographic assessment of LV volumes and ejection fraction. Time-to-peak radial strain was measured for 6 midventricular LV segments with speckle-tracking strain imaging. Moreover, the time difference between the peak radial strain of the anteroseptal and the posterior segments was calculated to obtain LV dyssynchrony. After 6 months, LV volumes, segmental LV mechanical activation timings, and LV dyssynchrony were reassessed. Response to CRT was defined as ≥15% decrease in LV end-systolic volume at 6-month follow-up. Responders (n = 177) showed LV resynchronization 6 months after CRT (LV dyssynchrony from 200 ± 127 to 85 ± 86 ms; p <0.001) by earlier activation of the posterior segment (from 438 ± 141 to 394 ± 132 ms; p = 0.001) and delayed activation of the anteroseptal segment (from 295 ± 155 to 407 ± 138 ms; p <0.001). In contrast, nonresponders (n = 115) experienced an increase in LV dyssynchrony 6 months after CRT (from 106 ± 86 to 155 ± 112 ms; p = 0.001) with an earlier activation of posterior wall (from 391 ± 139 to 355 ± 136 ms; p = 0.039) that did not match the delayed anteroseptal activation (from 360 ± 148 to 415 ± 122 ms; p = 0.001). In conclusion, responders to CRT showed LV resynchronization through balanced lateral and anteroseptal activations. In nonresponders, LV dyssynchrony remains, by posterior wall preactivation and noncompensatory delayed septal wall activation.


Subject(s)
Echocardiography/methods , Heart Failure/therapy , Heart Ventricles/diagnostic imaging , Myocardial Revascularization/methods , Ventricular Function, Left/physiology , Ventricular Remodeling , Aged , Female , Follow-Up Studies , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Humans , Male , Stroke Volume , Treatment Outcome
10.
Heart Vessels ; 29(5): 619-28, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24072137

ABSTRACT

The aim of the current study was to evaluate the prognostic implications of myocardial tissue heterogeneity assessed with two-dimensional speckle-tracking echocardiography in patients three months after first ST-segment elevation myocardial infarction (STEMI) with left ventricular ejection fraction (LVEF) ≤35 %. For this purpose, a total of 79 patients with first STEMI and LVEF ≤35 % at three months postinfarction were evaluated. Based on left ventricular (LV) speckle-tracking longitudinal strain echocardiography, the infarct core, border zone, and remote zone at baseline and three months' follow-up were defined. Patients were followed for the occurrence of the composite end point of appropriate implantable cardioverter-defibrillator (ICD) therapy and/or cardiac mortality. During a median follow-up of 46 months, 13 patients (17 %) reached the composite end point. At baseline, patients with and without events showed comparable values of LV longitudinal strain at the infarct, border, and remote zones. However, at three months' follow-up, patients with events showed significantly more impaired longitudinal strain at the border zone (-6.8 ± 3.1 % vs. -10.5 ± 4.9 %, P = 0.002), whereas LVEF was comparable (28 ± 6 % vs. 31 ± 4 %, P = 0.09). The median three-month LV longitudinal strain at the border zone was -9.4 %. Multivariate Cox regression analysis demonstrated that three-month longitudinal strain >-9.4 % at the border zone was independently associated with the composite end point (hazard ratio 3.94, 95 % confidence interval 1.05-14.70; P = 0.04). In conclusion, regional longitudinal strain at the border zone three months post-STEMI is associated with appropriate ICD therapy and cardiac mortality.


Subject(s)
Echocardiography, Doppler , Heart Ventricles/diagnostic imaging , Myocardial Contraction , Myocardial Infarction/diagnostic imaging , Stroke Volume , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left , Aged , Defibrillators, Implantable , Electric Countershock/instrumentation , Female , Heart Ventricles/physiopathology , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/mortality , Myocardial Infarction/physiopathology , Predictive Value of Tests , Proportional Hazards Models , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/therapy
11.
Pacing Clin Electrophysiol ; 37(1): 25-34, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23998638

ABSTRACT

BACKGROUND: Although randomized trials have shown the beneficial effect on survival of an implantable cardioverter defibrillator (ICD) as primary prevention therapy in selected patients, data concerning the cost-effectiveness in routine clinical practice remain scarce. Accordingly, the purpose of this study was to assess the cost-effectiveness of primary prevention ICD implantation in the real world. METHODS: Patients receiving primary prevention single-chamber or dual-chamber ICD implantation at the Leiden University Medical Center were included in the study. Using a Markov model, lifetime cost, life years (LYs), and gained quality-adjusted life years (QALYs) were estimated for device recipients and control patients. Data on mortality, complication rates, and device longevity were retrieved from our center and entered into the Markov model. To account for model assumptions, one-way deterministic and probabilistic sensitivity analyses were performed. Importantly, calculations for the estimated incremental cost-effectiveness rate (ICER) per QALY gained are based on several numbers of assumptions, and accordingly findings may have over- or underestimated the cost-effectiveness of ICD therapy. RESULTS: Primary prevention ICD implantation adds an estimated mean of 2.07 LYs and 1.73 QALYs. Increased lifetime cost for single-chamber and dual-chamber ICD recipients were estimated at €60,788 and €64,216, respectively. This resulted for single-chamber ICD recipients, in an estimated ICER of €35,154 per QALY gained. In dual-chamber ICD recipients, an estimated ICER of €37,111 per QALY gained was calculated. According to the probabilistic sensitivity analysis, estimated cost per QALY gained are €35,837 (95% confidence interval [CI]: €28,368-€44,460) for single-chamber and €37,756 (95% CI: €29,055-€46,050) for dual-chamber ICDs. CONCLUSIONS: On the basis of data and detailed costs, derived from routine clinical practice, ICD therapy in selected patients with a reduced left ventricular ejection fraction appears to be cost-effective.


Subject(s)
Defibrillators, Implantable/economics , Health Care Costs/statistics & numerical data , Heart Failure/economics , Heart Failure/prevention & control , Primary Prevention/economics , Cost-Benefit Analysis/economics , Female , Heart Failure/mortality , Humans , Male , Middle Aged , Netherlands/epidemiology , Prevalence , Registries , Risk Factors , Survival Rate , Treatment Outcome
12.
Pacing Clin Electrophysiol ; 36(11): 1391-401, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23826659

ABSTRACT

BACKGROUND: The relationship between changes in N-terminal pro-brain natriuretic peptide (NT-proBNP) and echocardiographic or clinical definitions of response to cardiac resynchronization therapy (CRT) has not been evaluated. The aims of the present evaluation were to assess: (1) the relationship between changes in NT-proBNP after 6 months of CRT and clinical and echocardiographic responses; (2) the association between NT-proBNP changes and long-term outcome. METHODS: In 170 patients treated with CRT (age 61 ± 11 years, 75% male), clinical and echocardiographic parameters and circulating NT-proBNP levels were assessed at baseline and 6 months after CRT. At 6 months follow-up, improvement in New York Heart Association class ≥ 1 point, decrease in left ventricular end-systolic volume ≥ 15%, and decrease in NT-proBNP ≥ 15% defined clinical, echocardiographic, and neurohormonal CRT response, respectively. All-cause mortality data were collected and related to neurohormonal response. RESULTS: Neurohormonal, echocardiographic, and clinical response rates were 54%, 58%, and 66%, respectively. The majority of patients (71%) showing echocardiographic response had NT-proBNP reduction ≥ 15%. In contrast, only 58% of patients who showed clinical response also had NT-proBNP reduction ≥ 15%. During a median follow-up of 32 months, 40 patients died. Patients with neurohormonal response demonstrated a superior long-term outcome compared to patients without neurohormonal response (log-rank P = 0.02). CONCLUSIONS: NT-proBNP reduction ≥ 15% showed better agreement with echocardiographic response compared to clinical response. Neurohormonal response was associated with superior long-term outcome compared to insufficient reduction in NT-proBNP levels.


Subject(s)
Cardiac Resynchronization Therapy/mortality , Cardiac Resynchronization Therapy/statistics & numerical data , Echocardiography/statistics & numerical data , Heart Failure/mortality , Heart Failure/prevention & control , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Biomarkers/blood , Chronic Disease , Female , Heart Failure/diagnosis , Humans , Male , Middle Aged , Netherlands/epidemiology , Neurotransmitter Agents/blood , Prevalence , Prognosis , Reproducibility of Results , Risk Factors , Sensitivity and Specificity , Survival Rate , Treatment Outcome , Ventricular Remodeling
13.
Heart ; 99(17): 1244-9, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23723448

ABSTRACT

OBJECTIVE: To assess differences in clinical outcome of implantable cardioverter-defibrillator (ICD) treatment in men and women. DESIGN: Prospective cohort study. SETTING: University Medical Center. PATIENTS: 1946 primary prevention ICD recipients (1528 (79%) men and 418 (21%) women). Patients with congenital heart disease were excluded for this analysis. MAIN OUTCOME MEASURES: All-cause mortality, ICD therapy (antitachycardia pacing and shock) and ICD shock. RESULTS: During a median follow-up of 3.3 years (25th-75th percentile 1.4-5.4), 387 (25%) men and 76 (18%) women died. The estimated 5-year cumulative incidence for all-cause mortality was 20% (95% CI 18% to 23%) for men and 14% (95% CI 9% to 19%) for women (log rank p<0.01). After adjustment for potential confounding covariates all-cause mortality was lower in women (HR 0.65; 95% CI 0.49 to 0.84; p<0.01). The 5-year cumulative incidence for appropriate therapy in men was 24% (95% CI 21% to 28%) as compared with 20% (95% CI 14% to 26%) in women (log rank p=0.07). After adjustment, a non-significant trend remained (HR 0.82; 95% CI 0.64 to 1.06; p=0.13). CONCLUSIONS: In clinical practice, 21% of primary prevention ICD recipients are women. Women have lower mortality and tend to experience less appropriate ICD therapy as compared with their male peers.


Subject(s)
Arrhythmias, Cardiac/therapy , Coronary Artery Disease/therapy , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/statistics & numerical data , Aged , Cohort Studies , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Proportional Hazards Models , Prospective Studies , Sex Factors , Treatment Outcome
14.
Heart ; 99(14): 1018-23, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23704324

ABSTRACT

OBJECTIVE: To assess the proportion of current implantable cardioverter defibrillator (ICD) recipients who would be suitable for a subcutaneous lead ICD (S-ICD). DESIGN: A retrospective cohort study. SETTING: Tertiary care facility in the Netherlands. PATIENTS: All patients who received a single- or dual-chamber ICD in the Leiden University Medical Center between 2002 and 2011. Patients with a pre-existent indication for cardiac pacing were excluded. MAIN OUTCOME MEASURE: Suitability for an S-ICD defined as not reaching one of the following endpoints during follow-up: (1) an atrial and/or right ventricular pacing indication, (2) successful antitachycardia pacing without a subsequent shock or (3) an upgrade to a CRT-D device. RESULTS: During a median follow-up of 3.4 years (IQR 1.7-5.7 years), 463 patients (34% of the total population of 1345 patients) reached an endpoint. The cumulative incidence of ICD recipients suitable for an initial S-ICD implantation was 55.5% (95% CI 52.0% to 59.0%) after 5 years. Significant predictors for the unsuitability of an S-ICD were: secondary prevention, severe heart failure and prolonged QRS duration. CONCLUSIONS: After 5 years of follow-up, approximately 55% of the patients would have been suitable for an S-ICD implantation. Several baseline clinical characteristics were demonstrated to be useful in the selection of patients suitable for an S-ICD implantation.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Secondary Prevention/methods , Tachycardia, Ventricular/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Netherlands/epidemiology , Retrospective Studies , Risk Factors , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/mortality
15.
Heart ; 99(10): 722-8, 2013 May.
Article in English | MEDLINE | ID: mdl-23315608

ABSTRACT

OBJECTIVES: Right ventricular (RV) function is an important prognostic marker in heart failure. However, its impact on all-cause mortality following cardiac resynchronisation therapy (CRT) independent of confounding factors has not been evaluated. Furthermore, evidence concerning the effect of CRT on RV function is limited. The study's aims were to: (1) assess the prognostic importance of RV function among CRT recipients, and (2) characterise RV functional change following CRT and its determinants. DESIGN: Retrospective observational study. SETTING: Single tertiary centre. PATIENTS: A total of 848 CRT recipients (median age 65 years, 78% male, 60% ischaemic) underwent echocardiography before and 6 months after CRT. RV function was evaluated using tricuspid annular plane systolic excursion (TAPSE), with a ≤14 mm threshold indicating severe RV impairment. The primary endpoint was long-term all-cause mortality. RESULTS: Significant baseline RV dysfunction was observed in 286 (34%) individuals. After a median 44 months, 288 deaths occurred. RV impairment was associated with a greater incidence of all-cause mortality (log-rank p<0.001). Independent predictors of this endpoint were functional class, ischaemic aetiology, diabetes, atrial fibrillation, renal dysfunction, bigger left ventricular (LV) end-systolic volume, less LV dyssynchrony and reduced TAPSE. Importantly, TAPSE added prognostic value to these recognised prognostic parameters (likelihood-ratio test p<0.001). Furthermore, improvement in RV function after CRT was independent of the improvement in LV systolic function but significantly associated with the improvement in LV diastolic function. Importantly, a favourable RV functional response to CRT was associated with superior survival. CONCLUSIONS: RV function is an independent predictor of long-term outcome following CRT.


Subject(s)
Cardiac Resynchronization Therapy/methods , Heart Failure/mortality , Ventricular Function, Right/physiology , Aged , Echocardiography, Doppler , Female , Follow-Up Studies , Heart Failure/physiopathology , Heart Failure/therapy , Humans , Male , Middle Aged , Netherlands/epidemiology , Prognosis , Retrospective Studies , Survival Rate/trends
16.
Diabetes Care ; 36(4): 985-91, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23223348

ABSTRACT

OBJECTIVE: The influence of diabetes on cardiac resynchronization therapy (CRT) remains unclear. The aims of the current study were to 1) assess the changes in left ventricular (LV) systolic and diastolic function and 2) evaluate long-term prognosis in CRT recipients with diabetes. RESEARCH DESIGN AND METHODS: A total of 710 CRT recipients (171 with diabetes) were included from an ongoing registry. Echocardiographic evaluation, including LV systolic and diastolic function assessment, was performed at baseline and 6-month follow-up. Response to CRT was defined as a reduction of ≥15% in LV end-systolic volume (LVESV) at the 6-month follow-up. During long-term follow-up (median = 38 months), all-cause mortality (primary end point) and cardiac death or heart failure hospitalization (secondary end point) were recorded. RESULTS: At the 6-month follow-up, significant LV reverse remodeling was observed both in diabetic and non-diabetic patients. However, the response to CRT occurred more frequently in non-diabetic patients than in diabetic patients (57 vs. 45%, P < 0.05). Furthermore, a significant improvement in LV diastolic function was observed both in diabetic and non-diabetic patients, but was more pronounced in non-diabetic patients. The determinants of the response to CRT among diabetic patients were LV dyssynchrony, ischemic cardiomyopathy, and insulin use. Both primary and secondary end points were more frequent in diabetic patients (P < 0.001). Particularly, diabetes was independently associated with all-cause mortality together with ischemic cardiomyopathy, renal function, LVESV, LV dyssynchrony, and LV diastolic dysfunction. CONCLUSIONS: Heart failure patients with diabetes exhibit significant improvements in LV systolic and diastolic function after CRT, although they are less pronounced than in non-diabetic patients. Diabetes was independently associated with all-cause mortality.


Subject(s)
Cardiac Resynchronization Therapy , Diastole/physiology , Systole/physiology , Aged , Diabetes Complications/physiopathology , Female , Humans , Male , Middle Aged , Ventricular Remodeling/physiology
18.
Heart Rhythm ; 9(10): 1605-12, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22522066

ABSTRACT

BACKGROUND: Although data on the mode of death of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy with defibrillator (CRT-D) patients have been examined in randomized clinical trials, in routine clinical practice data are scarce. To provide reasonable expectations and prognosis for patients and physicians, this study assessed the mode of death in routine clinical practice. OBJECTIVE: To assess the mode of death in ICD/CRT-D recipients in routine clinical practice. METHODS: All patients who underwent an ICD or CRT-D implantation at the Leiden University Medical Center, the Netherlands, between 1996 and 2010 were included. Patients were divided into primary prevention ICD, secondary prevention ICD, and CRT-D patients. For patients who died during follow-up, the mode of death was retrieved from hospital and general practitioner records and categorized according to a predetermined classification: heart failure death, other cardiac death, sudden death, noncardiac death, and unknown death. RESULTS: A total of 2859 patients were included in the analysis. During a median follow-up of 3.4 years (interquartile range 1.7-5.7 years), 107 (14%) primary prevention ICD, 253 (28%) secondary prevention ICD, and 302 (25%) CRT-D recipients died. The 8-year cumulative incidence of all-cause mortality was 39.9% (95% confidence interval 37.0%-42.9%). Heart failure death and noncardiac death were the most common modes of death for all groups. Sudden death accounted for approximately 7%-8% of all deaths. CONCLUSION: For all patients, heart failure and noncardiac death are the most common modes of death. The proportion of patients who died suddenly was low and comparable for primary and secondary ICD and CRT-D patients.


Subject(s)
Death, Sudden, Cardiac/epidemiology , Defibrillators, Implantable , Aged , Analysis of Variance , Cause of Death , Death, Sudden, Cardiac/prevention & control , Female , Follow-Up Studies , Humans , Male , Middle Aged , Netherlands/epidemiology , Primary Prevention , Risk Factors , Secondary Prevention
19.
Pacing Clin Electrophysiol ; 35(6): 652-8, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22352338

ABSTRACT

BACKGROUND: The performance of small diameter implantable cardioverter defibrillator (ICD) leads is questionable. However, data on performance during long-term follow-up are scarce. The aim of this study is to provide an update for the lead failure and cardiac perforation rate of Medtronic's Sprint Fidelis ICD lead (Medtronic Inc., Minneapolis, MN, USA) and St. Jude Medical's Riata ICD lead (St. Jude Medical Inc., St. Paul, MN, USA). METHODS: Since 1996, all ICD system implantations at the Leiden University Medical Center, the Netherlands, are registered. For this study, data up to February 2011 on 396 Sprint Fidelis leads (follow-up 3.4 ± 1.5 years), 165 8-French (F) Riata leads (follow-up 4.6 ± 2.6 years), and 30 7-F Riata leads (follow-up 2.9 ± 1.3 years) were compared with a benchmark cohort of 1,602 ICD leads (follow-up 3.4 ± 2.7 years) and assessed for the occurrence of lead failure and cardiac perforation. RESULTS: During follow-up, the yearly lead failure rate of the Sprint Fidelis lead, 7-F Riata lead, 8-F Riata lead, and the benchmark cohort was 3.54%, 2.28%, 0.78%, and 1.14%, respectively. In comparison to the benchmark cohort, the adjusted hazard ratio of lead failure was 3.7 (95% confidence interval [CI] 2.4-5.7, P < 0.001) for the Sprint Fidelis lead and 4.2 (95% CI 1.0-18.0, P < 0.05) for the 7-F Riata lead. One cardiac perforation was observed (3.3%) in the 7-F Riata group versus none in the 8-F Riata and Sprint Fidelis lead population. CONCLUSION: The current update demonstrates that the risk of lead failure during long-term follow-up is significantly increased for both the Sprint Fidelis and the 7-F Riata lead in comparison to the benchmark cohort. Only one cardiac perforation occurred.


Subject(s)
Defibrillators, Implantable/statistics & numerical data , Electrodes, Implanted/statistics & numerical data , Equipment Failure/statistics & numerical data , Heart Injuries/epidemiology , Postoperative Complications/epidemiology , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Netherlands/epidemiology , Prevalence , Risk Factors
20.
Eur Heart J ; 33(15): 1934-41, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22270539

ABSTRACT

AIMS: The aims of this study were: (i) to characterize consecutive cardiac resynchronization therapy (CRT) recipients with right bundle branch block (RBBB) in comparison with left bundle branch block (LBBB) and (ii) to identify independent predictors of long-term outcome among CRT recipients with RBBB. The presence of RBBB has been associated with poorer prognosis after CRT compared with LBBB; however, little is known about the differences in cardiac mechanics between RBBB and LBBB patients. Furthermore, predictors of favourable outcome after CRT in patients with RBBB have not been identified. METHODS AND RESULTS: Five hundred and sixty-one consecutive CRT recipients (89 with RBBB and 472 with LBBB) underwent echocardiography before and 6 months after CRT to determine left ventricular (LV) size and function, and interventricular and LV dyssynchrony (as measured by tissue Doppler imaging). Long-term follow-up to identify a composite endpoint of all-cause mortality or heart failure hospitalization was available. Right bundle branch block patients exhibited a higher prevalence of male gender, ischaemic heart disease, atrial fibrillation, and lower exercise capacity when compared with LBBB patients, despite smaller LV volumes. In addition, the extent of both interventricular and LV dyssynchrony was less in RBBB patients. Six months after CRT, RBBB patients also showed limited LV reverse remodelling. At long-term follow-up, LV dyssynchrony and mitral regurgitation were identified as independent predictors of all-cause mortality or heart failure hospitalization among RBBB patients. CONCLUSION: Left ventricular dyssynchrony may be an important determinant of outcome following CRT in patients with RBBB and may help in the selection of CRT candidates.


Subject(s)
Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/methods , Aged , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Electrocardiography , Epidemiologic Methods , Female , Humans , Male , Treatment Outcome , Ventricular Remodeling/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...